An electrochemical PAH-modified aptasensor for the label-free and highly-sensitive detection of saxitoxin

被引:22
|
作者
Noureen, Beenish [1 ]
Ullah, Najeeb [2 ]
Tian, Yulan [1 ]
Du, Liping [1 ,3 ]
Chen, Wei [1 ]
Wu, Chunsheng [1 ]
Wang, Ping [3 ]
机构
[1] Xi An Jiao Tong Univ, Hlth Sci Ctr, Sch Basic Med Sci, Inst Med Engn,Dept Biophys, Xian 710061, Shaanxi, Peoples R China
[2] Xi An Jiao Tong Univ, Hlth Sci Ctr, Sch Basic Med Sci, Dept Biochem & Mol Biol, Xian 710061, Shaanxi, Peoples R China
[3] Zhejiang Univ, Dept Biomed Engn, Biosensor Natl Special Lab, Key Lab Biomed Engn,Minist Educ, Hangzhou 310027, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrolyte-insulator-semiconductor sensor; Aptamer; Saxitoxin; Biosensors; Marine toxin; LIQUID-CHROMATOGRAPHY; DNA; APTAMER; IMMUNOASSAY; BIOSENSOR; SELECTION; AFFINITY; BINDING;
D O I
10.1016/j.talanta.2021.123185
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Saxitoxin (STX), is one of the most dangerous and widespread paralytic shellfish toxins, causing a severe threat to the ecosystem and human health. So, it is important and highly essential to develop novel techniques for STX detection in a convenient, desirable, and low-cost manner. Herein, this study developed an electrolyte-insulator semiconductor (EIS) sensor covered with a layer-by-layer prepared, positively-charged weak polyelectrolyte layer of poly (allylamine hydrochloride) (PAH) for the label-free detection of STX. The specific aptamer (Apt) sensitive to STX was electrostatically adsorbed onto the PAH layer. This leads to a preferentially flat orientation of the Apt within the Debye length, thus yielding a reduced charge-screening influence and a higher sensor signal. Each step of sensor surface modification, i.e. PAH adsorption, immobilization of Apt, and attachment of STX, was monitored by capacitance-voltage (C-V) and constant-capacitance (ConCap) measurements. Furthermore, atomic force microscopy (AFM) was employed to characterize the surface morphology and roughness of the PAH layer. Fluorescence microscopy was used to confirm the effective immobilization of Apt onto the PAHmodified EIS sensor. The results showed that the detection range of this aptasensor for STX detection was 0.5-100 nM and the detection limit was as low as 0.05 nM. Furthermore, this aptasensor showed good selectivity and 9 days' stability. The mussel tissue extraction test suggested that this aptasensor can be used to detect STX in real samples. This aptasensor provides a convenient approach for moderate, rapid, and label-free detection of marine biological toxins.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] A label free, signal off electrochemical aptasensor for amphetamine detection
    Soni, Shringika
    Jain, Utkarsh
    Burke, Donald H.
    Chauhan, Nidhi
    SURFACES AND INTERFACES, 2022, 31
  • [32] Highly sensitive label-free electrochemical aptasensors based on photoresist derived carbon for cancer biomarker detection
    Forouzanfar, Shahrzad
    Alam, Fahmida
    Pala, Nezih
    Wang, Chunlei
    BIOSENSORS & BIOELECTRONICS, 2020, 170
  • [33] A novel and label-free electrochemical aptasensor based on exonuclease III and G-quadruplex DNAzyme for sensitive and selective detection of metronidazole
    Du, Meijuan
    Chen, Qian
    Xu, Xueqin
    MICROCHEMICAL JOURNAL, 2022, 179
  • [34] A label-free electrochemical aptasensor for 8-hydroxy-2′-deoxyguanosine detection
    Shi, Shan-Shan
    Jia, Li-Ping
    Ma, Rong-Na
    Jia, Wen-Li
    Wang, Huai-Sheng
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 759 : 107 - 112
  • [35] Development of a label-free electrochemical aptasensor for Rift Valley fever virus detection
    Alharbi, Maha A.
    Rhouati, Amina
    Zourob, Mohammed
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [36] Development of a Label Free IGE Sensitive Aptasensor Based on Electrochemical Impedance Spectrometry
    Kara, Pinar
    Meric, Buket
    Ozsoz, Mehmet
    COMBINATORIAL CHEMISTRY & HIGH THROUGHPUT SCREENING, 2010, 13 (07) : 578 - 581
  • [37] A Simple and Sensitive Approach for Ochratoxin A Detection Using a Label-Free Fluorescent Aptasensor
    Lv, Zhenzhen
    Chen, Ailiang
    Liu, Jinchuan
    Guan, Zheng
    Zhou, Yu
    Xu, Siyuan
    Yang, Shuming
    Li, Cheng
    PLOS ONE, 2014, 9 (01):
  • [38] A label-free aptasensor for highly sensitive ATP detection by using exonuclease I and oligonucleotide-templated fluorescent copper nanoparticles
    Cai, Qiyong
    Ge, Jia
    Xu, Huihui
    Zhang, Lin
    Hu, Yalei
    Huang, Zhongming
    Li, Zhaohui
    ANALYTICAL METHODS, 2017, 9 (18) : 2710 - 2714
  • [39] A Label-Free Electrochemical DNA Aptasensor for the Detection of Dopamine
    Jarczewska, Marta
    Sheelam, Sravanthi Reddy
    Ziolkowski, Robert
    Gorskiz, Lukasz
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2016, 163 (03) : B26 - B31
  • [40] A label-free aptasensor for highly sensitive detection of ATP and thrombin based on metal-enhanced PicoGreen fluorescence
    Wang, Kaiyu
    Liao, Jian
    Yang, Xiangyue
    Zhao, Meng
    Chen, Min
    Yao, Weirong
    Tan, Weihong
    Lan, Xiaopeng
    BIOSENSORS & BIOELECTRONICS, 2015, 63 : 172 - 177