An electrochemical PAH-modified aptasensor for the label-free and highly-sensitive detection of saxitoxin

被引:22
|
作者
Noureen, Beenish [1 ]
Ullah, Najeeb [2 ]
Tian, Yulan [1 ]
Du, Liping [1 ,3 ]
Chen, Wei [1 ]
Wu, Chunsheng [1 ]
Wang, Ping [3 ]
机构
[1] Xi An Jiao Tong Univ, Hlth Sci Ctr, Sch Basic Med Sci, Inst Med Engn,Dept Biophys, Xian 710061, Shaanxi, Peoples R China
[2] Xi An Jiao Tong Univ, Hlth Sci Ctr, Sch Basic Med Sci, Dept Biochem & Mol Biol, Xian 710061, Shaanxi, Peoples R China
[3] Zhejiang Univ, Dept Biomed Engn, Biosensor Natl Special Lab, Key Lab Biomed Engn,Minist Educ, Hangzhou 310027, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrolyte-insulator-semiconductor sensor; Aptamer; Saxitoxin; Biosensors; Marine toxin; LIQUID-CHROMATOGRAPHY; DNA; APTAMER; IMMUNOASSAY; BIOSENSOR; SELECTION; AFFINITY; BINDING;
D O I
10.1016/j.talanta.2021.123185
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Saxitoxin (STX), is one of the most dangerous and widespread paralytic shellfish toxins, causing a severe threat to the ecosystem and human health. So, it is important and highly essential to develop novel techniques for STX detection in a convenient, desirable, and low-cost manner. Herein, this study developed an electrolyte-insulator semiconductor (EIS) sensor covered with a layer-by-layer prepared, positively-charged weak polyelectrolyte layer of poly (allylamine hydrochloride) (PAH) for the label-free detection of STX. The specific aptamer (Apt) sensitive to STX was electrostatically adsorbed onto the PAH layer. This leads to a preferentially flat orientation of the Apt within the Debye length, thus yielding a reduced charge-screening influence and a higher sensor signal. Each step of sensor surface modification, i.e. PAH adsorption, immobilization of Apt, and attachment of STX, was monitored by capacitance-voltage (C-V) and constant-capacitance (ConCap) measurements. Furthermore, atomic force microscopy (AFM) was employed to characterize the surface morphology and roughness of the PAH layer. Fluorescence microscopy was used to confirm the effective immobilization of Apt onto the PAHmodified EIS sensor. The results showed that the detection range of this aptasensor for STX detection was 0.5-100 nM and the detection limit was as low as 0.05 nM. Furthermore, this aptasensor showed good selectivity and 9 days' stability. The mussel tissue extraction test suggested that this aptasensor can be used to detect STX in real samples. This aptasensor provides a convenient approach for moderate, rapid, and label-free detection of marine biological toxins.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Label-Free Detection of Saxitoxin with Field-Effect Device-Based Biosensor
    Ullah, Najeeb
    Noureen, Beenish
    Tian, Yulan
    Du, Liping
    Chen, Wei
    Wu, Chunsheng
    NANOMATERIALS, 2022, 12 (09)
  • [22] Highly sensitive and selective optical detection of lead(II) using a label-free fluorescent aptasensor
    Huang, Yafei
    Yan, Jiao
    Fang, Zongzhuang
    Zhang, Chenghui
    Bai, Wenhui
    Yan, Mengmeng
    Zhu, Chao
    Gao, Chengguo
    Chen, Ailiang
    RSC ADVANCES, 2016, 6 (93): : 90300 - 90304
  • [23] A graphene functionalized electrochemical aptasensor for selective label-free detection of cancer cells
    Feng, Lingyan
    Chen, Yong
    Ren, Jinsong
    Qu, Xiaogang
    BIOMATERIALS, 2011, 32 (11) : 2930 - 2937
  • [24] High sensitive rapid visual detection of sulfadimethoxine by label-free aptasensor
    Chen, Ailiang
    Jiang, Xiaoling
    Zhang, Weiwei
    Chen, Gang
    Zhao, Yan
    Tunio, Tarique Muhammad
    Liu, Jinchuan
    Lv, Zhenzhen
    Li, Cheng
    Yang, Shuming
    BIOSENSORS & BIOELECTRONICS, 2013, 42 : 419 - 425
  • [25] An Electrochemical Ti3C2Tx Aptasensor for Sensitive and Label-Free Detection of Marine Biological Toxins
    Ullah, Najeeb
    Chen, Wei
    Noureen, Beenish
    Tian, Yulan
    Du, Liping
    Wu, Chunsheng
    Ma, Jie
    SENSORS, 2021, 21 (14)
  • [26] Portable label-free electrochemical aptasensor for sensitive detection of paraquat herbicide mediated by oxygen reduction reaction
    Phopin, Kamonrat
    Ruankham, Waralee
    Dave, Jaydeep
    Rukkhapiban, Piracha
    Nuttavuttisit, Chayatis
    Hongoeb, Juthamas
    Zine, Nadia
    Errachid, Abdelhamid
    Tantimongcolwat, Tanawut
    TALANTA, 2025, 281
  • [27] A sensitive aptasensor based on molybdenum carbide nanotubes and label-free aptamer for detection of bisphenol A
    He, Meng-Qi
    Wang, Kun
    Wang, Jin
    Yu, Yong-Liang
    He, Rong-Huan
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (07) : 1797 - 1803
  • [28] A Label-Free Fluorescent AND Logic Gate Aptasensor for Sensitive ATP Detection
    Zhang, Jingjing
    Yang, Chunzheng
    Niu, Chaoqun
    Liu, Chen
    Cai, Xuepin
    Du, Jie
    Chen, Yong
    SENSORS, 2018, 18 (10)
  • [29] Label-free and sensitive electrogenerated chemiluminescence aptasensor for the determination of lysozyme
    Li, Yan
    Qi, Honglan
    Gao, Qiang
    Zhang, Chengxiao
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (05) : 2733 - 2736
  • [30] Electrochemical determination of zearalenone using a label-free competitive aptasensor
    Azri, Farah Asilah
    Eissa, Shimaa
    Zourob, Mohammed
    Chinnappan, Raja
    Sukor, Rashidah
    Yusof, Nor Azah
    Raston, Nurul Hanun Ahmad
    Alhoshani, Ali
    Jinap, Selamat
    MICROCHIMICA ACTA, 2020, 187 (05)