Performance of a Wet Flue Gas Desulfurization Pilot Plant under Oxy-Fuel Conditions

被引:26
作者
Hansen, Brian B. [1 ]
Fogh, Folmer [2 ]
Knudsen, Niels Ole [3 ]
Kiil, Soren [1 ]
机构
[1] Tech Univ Denmark, Dept Chem & Biochem Engn, DK-2800 Kongens Lyngby, Denmark
[2] Dong Energy AS, DK-7000 Fredericia, Denmark
[3] Vattenfall AS, DK-9310 Vodskov, Denmark
关键词
AQUEOUS SUSPENSIONS; DISSOLUTION RATE; SOLID PARTICLES; LIMESTONE; CO2;
D O I
10.1021/ie1022173
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Oxy-fuel firing is a promising technology that should enable the capture and storage of anthropogenic CO2 emissions from large stationary sources such as power plants and heavy industry. However, this new technology has a high energy demand for air separation and CO2 compression and storage. Unresolved issues, such as determination of the optimal recycle location of flue gas, the flue gas cleaning steps required (SO2, NOx, and particles), and the impact of an oxy-fuel flue gas on the cleaning steps, also persist. The aim of this work was to study the performance of the wet flue gas desulfurization (FGD) process under operating conditions corresponding to oxy-fuel firing. The most important output parameters were the overall degree of desulfurization and the residual limestone concentration in the gypsum slurry. Pilot scale experiments quantified that the introduction of a flue gas with 90 vol % CO2, at a holding tank pH 5.4, reduced the limestone dissolution rate significantly and thereby increased the residual, particulate limestone concentration in the gypsum slurry from 3.2 to 5.0 g/L slurry relative to a base case (air firing) experiment with flue gas CO2 concentration around 7 vol %. In the same experiment, due to the higher residual limestone concentration, the degree of desulfurization increased from 91 to 94%. The addition of 10 mM adipic acid to the slurry was not sufficient to return the increased concentration of residual limestone to the base case level, but an additional increase in desulfurization degree, from 94 to 97%, was obtained. Using a holding tank pH 5.0 (no adipic acid) returned both parameters to the levels observed in the base case experiment.
引用
收藏
页码:4238 / 4244
页数:7
相关论文
共 21 条
[1]   Modeling and measurement of the dissolution rate of solid particles in aqueous suspensions - Part II: Experimental results and validation [J].
Allers, T ;
Luckas, M ;
Schmidt, KG .
CHEMICAL ENGINEERING & TECHNOLOGY, 2003, 26 (12) :1225-1229
[2]   Modeling and measurement of the dissolution rate of solid particles in aqueous suspensions - Part I: Modeling [J].
Allers, T ;
Luckas, M ;
Schmidt, KG .
CHEMICAL ENGINEERING & TECHNOLOGY, 2003, 26 (11) :1131-1136
[3]  
BREWER L, 1982, ACS S SERIES, V188
[4]   Experimental investigation of the degradation rate of adipic acid in wet flue gas desulphurisation plants [J].
Buchardt, CN ;
Johnsson, JE ;
Kiil, S .
FUEL, 2006, 85 (5-6) :725-735
[5]   Oxy-fuel combustion technology for coal-fired power generation [J].
Buhre, BJP ;
Elliott, LK ;
Sheng, CD ;
Gupta, RP ;
Wall, TF .
PROGRESS IN ENERGY AND COMBUSTION SCIENCE, 2005, 31 (04) :283-307
[6]  
CHAN PK, 1982, ACS SYM SER, V188, P75
[7]  
DOCTOR RD, 2008, 7 ANN C CARB CAPT SE
[8]   Optimisation of a wet FGD pilot plant using fine limestone and organic acids [J].
Frandsen, JBW ;
Kiil, S ;
Johnsson, JE .
CHEMICAL ENGINEERING SCIENCE, 2001, 56 (10) :3275-3287
[9]  
GONSCHOREK S, 2006, KRAFTW K ZITT GERM S
[10]  
Gubkov A.N., 1964, Zhurnal prikladnoi khimii (Journal of applied chemistry of the USSR), V37, P2204