Response of a transmission tower-line system at a canyon site to spatially varying ground motions

被引:9
作者
Li, Hong-nan [1 ]
Bai, Feng-long [1 ,2 ]
Tian, Li [1 ]
Hao, Hong [2 ]
机构
[1] Dalian Univ Technol, State Key Lab Coastal & Offshore Engn, Dalian 116024, Peoples R China
[2] Univ Western Australia, Sch Civil & Resource Engn, Perth, WA 6009, Australia
来源
JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A | 2011年 / 12卷 / 02期
基金
中国国家自然科学基金; 高等学校博士学科点专项科研基金;
关键词
Transmission tower-line system; Canyon site; Spatially varying ground motions; Coherency loss; Local site effect; INELASTIC DYNAMIC-ANALYSIS; SEISMIC RESPONSE; BRIDGES; VARIABILITY;
D O I
10.1631/jzus.A1000067
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Collapses of transmission towers were often observed in previous large earthquakes such as the Chi-Chi earthquake in Taiwan and Wenchuan earthquake in Sichuan, China. These collapses were partially caused by the pulling forces from the transmission lines generated from out-of-phase responses of the adjacent towers owing to spatially varying earthquake ground motions. In this paper, a 3D finite element model of the transmission tower-line system is established considering the geometric nonlinearity of transmission lines. The nonlinear responses of the structural system at a canyon site are analyzed subjected to spatially varying ground motions. The spatial variations of ground motion associated with the wave passage, coherency loss, and local site effects are given. The spatially varying ground motions are simulated stochastically based on an empirical coherency loss function and a filtered Tajimi-Kanai power spectral density function. The site effect is considered by a transfer function derived from ID wave propagation theory. Compared with structural responses calculated using the uniform ground motion and delayed excitations, numerical results indicate that seismic responses of transmission towers and power lines are amplified when considering spatially varying ground motions including site effects. Each factor of ground motion spatial variations has a significant effect on the seismic response of the structure, especially for the local site effect. Therefore, neglecting the earthquake ground motion spatial variations may lead to a substantial underestimation of the response of transmission tower-line system during strong earthquakes. Each effect of ground motion spatial variations should be incorporated in seismic analysis of the structural system.
引用
收藏
页码:103 / 120
页数:18
相关论文
共 33 条