An aggregation-induced emission (AIE)-active fluorescent chemodosimeter for selective sensing of hypochlorite in water and solid state: Endogenous detection of hypochlorite in live cells

被引:16
作者
Samanta, Sandip Kumar [1 ]
Maiti, Kalipada [1 ]
Manna, Saikat Kumar [2 ]
Ali, Syed Samim [1 ]
Guria, Uday Narayan [1 ]
Ghosh, Aritri [3 ]
Datta, Pallab [3 ]
Mahapatra, Ajit Kumar [1 ]
机构
[1] Indian Inst Engn Sci & Technol, Dept Chem, Sibpur 711103, Howrah, India
[2] Haldia Govt Coll, Dept Chem, Debhog 721657, W Bengal, India
[3] Indian Inst Engn Sci & Technol, Ctr Healthcare Sci & Technol, Sibpur, India
关键词
AIE; Turn-on chemodosimeter  Hypochlorite (ClO-); Theoretical study; Solid state sensing; Real water sample analysis; Cell imaging; LARGE STOKES SHIFT; RATIOMETRIC DETECTION; OXIDATIVE STRESS; LIVING CELLS; FAR-RED; PROBE; ACID; MYELOPEROXIDASE; HOCL; SYSTEM;
D O I
10.1016/j.dyepig.2021.109758
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Hypochlorite (ClO- ) being an important reactive oxygen species plays a crucial role in the oxidative damage to tissue and other various diseases. Highly selective, sensitive, and quick detection of aberrant ClO- is vital for the protection of living organisms and the environment. Accordingly, fluorescent molecules are most effective sensor system for ClO- . Herein, we have synthesized and characterized a water soluble AIE-active tetraphenylethylene (TPE)-based fluorescent molecule TPE-Py+ (TPP) for rapid (10 s) and selective detection of ClO- based on ClOinduced oxidation of N-alkylpyridinium to N-methyl-2-pyridone. ClO- mediated aggregation-induced emission (AIE) enhancement corresponds to turn-on response. Scanning electron microscopic (SEM) study supports AIE behavior of the probe upon treatment with ClO- . The detection limit of TPP for ClO- was found to be 8.89 nM and exhibited high selectivity among other possibly interfering analytes (ROS, RNS, other ions). TPP-based handy test kits were developed for the solid-state detection of ClO- in environmental samples. Furthermore, our probe was effective in detecting ClO- in real water samples, fetal bovine serum and able to detect endogenous ClO- in live cell.
引用
收藏
页数:9
相关论文
共 69 条
[31]   Zinspy sensors with enhanced dynamic range for imaging neuronal cell zinc uptake and mobilization [J].
Nolan, Elizabeth M. ;
Ryu, Jubin W. ;
Jaworski, Jacek ;
Feazell, Rodney P. ;
Sheng, Morgan ;
Lippard, Stephen J. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (48) :15517-15528
[32]   Ratiometric Two-Photon Fluorescent Probe for Detecting and Imaging Hypochlorite [J].
Pak, Yen Leng ;
Park, Sang Jun ;
Xu, Qingling ;
Kim, Hwan Myung ;
Yoon, Juyoung .
ANALYTICAL CHEMISTRY, 2018, 90 (15) :9510-9514
[33]   N-Heterocyclic Carbene Boranes as Reactive Oxygen Species-Responsive Materials: Application to the Two-Photon Imaging of Hypochlorous Acid in Living Cells and Tissues [J].
Pak, Yen Leng ;
Park, Sang Jun ;
Wu, Di ;
Cheon, BoHyun ;
Kim, Hwan Myung ;
Bouffard, Jean ;
Yoon, Juyoung .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2018, 57 (06) :1567-1571
[34]   A hexaphenylbenzene based AIEE active two photon probe for the detection of hydrogen sulfide with tunable self-assembly in aqueous media and application in live cell imaging [J].
Pramanik, Subhamay ;
Bhalla, Vandana ;
Kim, Hwan Myung ;
Singh, Hardev ;
Lee, Hyo Won ;
Kumar, Manoj .
CHEMICAL COMMUNICATIONS, 2015, 51 (85) :15570-15573
[35]   AIE Luminogens for Bioimaging and Theranostics: from Organelles to Animals [J].
Qian, Jun ;
Tang, Ben Zhong .
CHEM, 2017, 3 (01) :56-91
[36]   An ultrafast responsive BODIPY-based fluorescent probe for the detection of endogenous hypochlorite in live cells [J].
Qiao, Liang ;
Nie, Hailiang ;
Wu, Yulong ;
Xin, Fangyun ;
Gao, Congcong ;
Jing, Jing ;
Zhang, Xiaoling .
JOURNAL OF MATERIALS CHEMISTRY B, 2017, 5 (03) :525-530
[37]   Single Fluorescent Probe Separately and Continuously Visualize H2S and HClO in Lysosomes with Different Fluorescence Signals [J].
Ren, Mingguang ;
Li, Zihong ;
Deng, Beibei ;
Wang, Li ;
Lin, Weiying .
ANALYTICAL CHEMISTRY, 2019, 91 (04) :2932-2938
[38]   A fluorescent probe with "AIE plus ESIPT" characteristics for Cu2+ and F- ions estimation [J].
Sen Gupta, Akul ;
Paul, Kamaldeep ;
Luxami, Vijay .
SENSORS AND ACTUATORS B-CHEMICAL, 2017, 246 :653-661
[39]   An attempt to prevent senescence: A mitochondrial approach [J].
Skulachev, Vladimir P. ;
Anisimov, Vladimir N. ;
Antonenko, Yuri N. ;
Bakeeva, Lora E. ;
Chernyak, Boris V. ;
Erichev, Valery P. ;
Filenko, Oleg F. ;
Kalinina, Natalya I. ;
Kapelko, Valery I. ;
Kolosova, Natalya G. ;
Kopnin, Boris P. ;
Korshunova, Galina A. ;
Lichinitser, Mikhail R. ;
Obukhova, Lidia A. ;
Pasyukova, Elena G. ;
Pisarenko, Oleg I. ;
Roginsky, Vitaly A. ;
Ruuge, Enno K. ;
Senin, Ivan I. ;
Severina, Inna I. ;
Skulachev, Maxim V. ;
Spivak, Irina M. ;
Tashlitsky, Vadim N. ;
Tkachuk, Vsevolod A. ;
Vyssokikh, Mikhail Yu. ;
Yaguzhinsky, Lev S. ;
Zorov, Dmitry B. .
BIOCHIMICA ET BIOPHYSICA ACTA-BIOENERGETICS, 2009, 1787 (05) :437-461
[40]   Myeloperoxidase and chlorinated peptides in osteoarthritis: Potential biornarkers of the disease [J].
Steinbeck, Maria J. ;
Nesti, Leon J. ;
Sharkey, Peter F. ;
Parvizi, Javad .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2007, 25 (09) :1128-1135