An aggregation-induced emission (AIE)-active fluorescent chemodosimeter for selective sensing of hypochlorite in water and solid state: Endogenous detection of hypochlorite in live cells

被引:16
作者
Samanta, Sandip Kumar [1 ]
Maiti, Kalipada [1 ]
Manna, Saikat Kumar [2 ]
Ali, Syed Samim [1 ]
Guria, Uday Narayan [1 ]
Ghosh, Aritri [3 ]
Datta, Pallab [3 ]
Mahapatra, Ajit Kumar [1 ]
机构
[1] Indian Inst Engn Sci & Technol, Dept Chem, Sibpur 711103, Howrah, India
[2] Haldia Govt Coll, Dept Chem, Debhog 721657, W Bengal, India
[3] Indian Inst Engn Sci & Technol, Ctr Healthcare Sci & Technol, Sibpur, India
关键词
AIE; Turn-on chemodosimeter  Hypochlorite (ClO-); Theoretical study; Solid state sensing; Real water sample analysis; Cell imaging; LARGE STOKES SHIFT; RATIOMETRIC DETECTION; OXIDATIVE STRESS; LIVING CELLS; FAR-RED; PROBE; ACID; MYELOPEROXIDASE; HOCL; SYSTEM;
D O I
10.1016/j.dyepig.2021.109758
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Hypochlorite (ClO- ) being an important reactive oxygen species plays a crucial role in the oxidative damage to tissue and other various diseases. Highly selective, sensitive, and quick detection of aberrant ClO- is vital for the protection of living organisms and the environment. Accordingly, fluorescent molecules are most effective sensor system for ClO- . Herein, we have synthesized and characterized a water soluble AIE-active tetraphenylethylene (TPE)-based fluorescent molecule TPE-Py+ (TPP) for rapid (10 s) and selective detection of ClO- based on ClOinduced oxidation of N-alkylpyridinium to N-methyl-2-pyridone. ClO- mediated aggregation-induced emission (AIE) enhancement corresponds to turn-on response. Scanning electron microscopic (SEM) study supports AIE behavior of the probe upon treatment with ClO- . The detection limit of TPP for ClO- was found to be 8.89 nM and exhibited high selectivity among other possibly interfering analytes (ROS, RNS, other ions). TPP-based handy test kits were developed for the solid-state detection of ClO- in environmental samples. Furthermore, our probe was effective in detecting ClO- in real water samples, fetal bovine serum and able to detect endogenous ClO- in live cell.
引用
收藏
页数:9
相关论文
共 69 条
[1]   pH-Dependent Si-Fluorescein Hypochlorous Acid Fluorescent Probe: Spirocycle Ring-Opening and Excess Hypochlorous Acid-Induced Chlorination [J].
Best, Quinn A. ;
Sattenapally, Narsimha ;
Dyer, Daniel J. ;
Scott, Colleen N. ;
McCarroll, Matthew E. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2013, 135 (36) :13365-13370
[2]  
Chan J, 2012, NAT CHEM, V4, P973, DOI [10.1038/NCHEM.1500, 10.1038/nchem.1500]
[3]   Recent progress in the development of fluorescent, luminescent and colorimetric probes for detection of reactive oxygen and nitrogen species [J].
Chen, Xiaoqiang ;
Wang, Fang ;
Hyun, Ji Young ;
Wei, Tingwen ;
Qiang, Jian ;
Ren, Xintong ;
Shin, Injae ;
Yoon, Juyoung .
CHEMICAL SOCIETY REVIEWS, 2016, 45 (10) :2976-3016
[4]   A "turn-on" fluorescent probe for hypochlorous acid: convenient synthesis, good sensing performance, and a new design strategy by the removal of C=N isomerization [J].
Cheng, Xiaohong ;
Jia, Huizhen ;
Long, Teng ;
Feng, Jun ;
Qin, Jingui ;
Li, Zhen .
CHEMICAL COMMUNICATIONS, 2011, 47 (43) :11978-11980
[5]   A Targetable Fluorescent Sensor Reveals That Copper-Deficient SCO1 and SCO2 Patient Cells Prioritize Mitochondrial Copper Homeostasis [J].
Dodani, Sheel C. ;
Leary, Scot C. ;
Cobine, Paul A. ;
Winge, Dennis R. ;
Chang, Christopher J. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2011, 133 (22) :8606-8616
[6]   In Vivo Imaging of Endogenously Produced HClO in Zebrafish and Mice Using a Bright, Photostable Ratiometric Fluorescent Probe [J].
Duan, Chong ;
Won, Miae ;
Verwilst, Peter ;
Xu, Junchao ;
Kim, Hyeong Seok ;
Zeng, Lintao ;
Kim, Jong Seung .
ANALYTICAL CHEMISTRY, 2019, 91 (06) :4172-4178
[7]   Rational Design of a Hepatoma-Specific Fluorescent Probe for HOCl and Its Bioimaging Applications in Living HepG2 Cells [J].
Duan, Qingxia ;
Jia, Pan ;
Zhuang, Zihan ;
Liu, Caiyun ;
Zhang, Xue ;
Wang, Zuokai ;
Sheng, Wenlong ;
Li, Zilu ;
Zhu, Hanchuang ;
Zhu, Baocun ;
Zhang, Xiaoling .
ANALYTICAL CHEMISTRY, 2019, 91 (03) :2163-2168
[8]   Rapid Response Fluorescence Probe Enabled In Vivo Diagnosis and Assessing Treatment Response of Hypochlorous Acid-Mediated Rheumatoid Arthritis [J].
Feng, Huan ;
Zhang, Zhiqiang ;
Meng, Qingtao ;
Jia, Hongmin ;
Wang, Yue ;
Zhang, Run .
ADVANCED SCIENCE, 2018, 5 (08)
[9]   Novel near-infrared fluorescent probe with a large Stokes shift for sensing hypochlorous acid in mitochondria [J].
Gong, Jin ;
Liu, Chang ;
Cai, Songtao ;
He, Song ;
Zhao, Liancheng ;
Zeng, Xianshun .
ORGANIC & BIOMOLECULAR CHEMISTRY, 2020, 18 (38) :7656-7662
[10]   Genotoxic effects of neutrophils and hypochlorous acid [J].
Gungor, Nejla ;
Knaapen, Ad M. ;
Munnia, Armelle ;
Peluso, Marco ;
Haenen, Guido R. ;
Chiu, Roland K. ;
Godschalk, Roger W. L. ;
van Schooten, Frederik J. .
MUTAGENESIS, 2010, 25 (02) :149-154