A correction algorithm to simultaneously control dual deformable mirrors in a woofer-tweeter adaptive optics system

被引:40
作者
Li, Chaohong [1 ]
Sredar, Nripun [1 ]
Ivers, Kevin M. [1 ]
Queener, Hope [1 ]
Porter, Jason [1 ]
机构
[1] Univ Houston, Coll Optometry, Houston, TX 77204 USA
关键词
SCANNING LASER OPHTHALMOSCOPY; COHERENCE TOMOGRAPHY; VISUAL PERFORMANCE; ABERRATIONS; COMPENSATION; ERROR;
D O I
10.1364/OE.18.016671
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present a direct slope-based correction algorithm to simultaneously control two deformable mirrors (DMs) in a woofer-tweeter adaptive optics system. A global response matrix was derived from the response matrices of each deformable mirror and the voltages for both deformable mirrors were calculated simultaneously. This control algorithm was tested and compared with a 2-step sequential control method in five normal human eyes using an adaptive optics scanning laser ophthalmoscope. The mean residual total root-mean-square (RMS) wavefront errors across subjects after adaptive optics (AO) correction were 0.128 +/- 0.025 mu m and 0.107 +/- 0.033 mu m for simultaneous and 2-step control, respectively (7.75-mm pupil). The mean intensity of reflectance images acquired after AO convergence was slightly higher for 2-step control. Radially-averaged power spectra calculated from registered reflectance images were nearly identical for all subjects using simultaneous or 2-step control. The correction performance of our new simultaneous dual DM control algorithm is comparable to 2-step control, but is more efficient. This method can be applied to any woofer-tweeter AO system. (C) 2010 Optical Society of America
引用
收藏
页码:16671 / 16684
页数:14
相关论文
共 32 条
[1]  
ANSI, 2000, ANSI 136.1-2000
[2]  
*ANSI INC, 2004, Z80282004 ANSI
[3]   MAGNIFICATION AND VISUAL-ACUITY IN REFRACTIVE SURGERY [J].
APPLEGATE, RA ;
HOWLAND, HC .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (10) :1335-1342
[4]   Volumetric retinal imaging with ultrahigh-resolution spectral-domain optical coherence tomography and adaptive optics using two broadband light sources [J].
Cense, Barry ;
Koperda, Eric ;
Brown, Jeffrey M. ;
Kocaoglu, Omer P. ;
Gao, Weihua ;
Jonnal, Ravi S. ;
Miller, Donald T. .
OPTICS EXPRESS, 2009, 17 (05) :4095-4111
[5]   High-resolution adaptive optics scanning laser ophthalmoscope with dual deformable mirrors [J].
Chen, Diana C. ;
Jones, Steven M. ;
Silva, Dennis A. ;
Olivier, Scot S. .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2007, 24 (05) :1305-1312
[6]   Individual variations in human cone photoreceptor packing density: Variations with refractive error [J].
Chui, Toco Yuen Ping ;
Song, HongXin ;
Burns, Stephen A. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (10) :4679-4687
[7]   Distributed modal command for a two-deformable-mirror adaptive optics system [J].
Conan, R. ;
Bradley, C. ;
Hampton, P. ;
Keskin, O. ;
Hilton, A. ;
Blain, C. .
APPLIED OPTICS, 2007, 46 (20) :4329-4340
[8]   Maximum permissible exposures for ocular safety (ANSI 2000), with emphasis on ophthalmic devices [J].
Delori, Francois C. ;
Webb, Robert H. ;
Sliney, David H. .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2007, 24 (05) :1250-1265
[9]   Error Budget Analysis for an Adaptive Optics Optical Coherence Tomography System [J].
Evans, Julia W. ;
Zawadzki, Robert J. ;
Jones, Steven M. ;
Olivier, Scot S. ;
Werner, John S. .
OPTICS EXPRESS, 2009, 17 (16) :13768-13784
[10]   Binocular adaptive optics visual simulator [J].
Fernandez, Enrique J. ;
Prieto, Pedro M. ;
Artal, Pablo .
OPTICS LETTERS, 2009, 34 (17) :2628-2630