The effect of software updates on the trueness and precision of intraoral scanners

被引:42
作者
Vag, Janos [1 ]
Renne, Walter [2 ]
Revell, Griffin [3 ]
Ludlow, Mark [4 ]
Mennito, Anthony [3 ]
Teich, Sorin T. [5 ]
Gutmacher, Zvi [6 ]
机构
[1] Semmeiweis Univ, Dept Conservat Dent, Budapest, Hungary
[2] Med Univ South Carolina, James B Edwards Coll Dent Med, Dept Oral Rehabil, Innovat & Digital Dent, Charleston, SC 29425 USA
[3] Med Univ South Carolina, James B Edwards Coll Dent Med, Charleston, SC 29425 USA
[4] Med Univ South Carolina, James B Edwards Coll Dent Med, Implant Prosthodont, Charleston, SC 29425 USA
[5] Med Univ South Carolina, James B Edwards Coll Dent Med, Dept Oral Rehabil, Clin Affairs, Charleston, SC 29425 USA
[6] Rambam Med Ctr, Dept Maxillofacial Rehabilitat & Temporomandibula, Haifa, Israel
来源
QUINTESSENCE INTERNATIONAL | 2021年 / 52卷 / 07期
关键词
CAD; CAM; digital dentistry; intraoral scanner; software; software update; CONVENTIONAL IMPRESSIONS; ACCURACY; SYSTEM; ADAPTATION; DESIGN;
D O I
10.3290/j.qi.b1098315
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The goal of the study was to determine the effects of software updates on the trueness and precision of digital impressions obtained with a variety of intraoral scanner (IOS) systems. Method and materials: Seven IOS systems were investigated. Each system was tested using two versions of software, with the second version being the latest at the time of conducting the study. Scans were performed on a custom mandibular typodont model with natural teeth that were either unrestored or restored with amalgam, composite, lithium disilicate, zirconia, and gold. Eight scans were obtained for each software version on any of the tested IOS systems. Experimental IOS scans were compared against an industry-standard master scan of the typodont obtained with an ATOS Capsule scanner proven to have a trueness of 3 mu m and a precision of 2 mu m. Isolation of each substrate material on the digital experimental and master scans was achieved using the Geomagic metrology software for subsequent analysis of the substrate influence on accuracy. A generalized linear mixed model was used to determine the influence of the software version on the trueness and precision of the impression scan. Results: For some IOS systems, scans made with older software versions differ in accuracy compared with those obtained with the most recent software versions. Trueness was improved for most scanners following the software update, although the Element2 IOS performance deteriorated. Software updates had lesser effects on precision and showed variable trends among different systems. Software updates also influence different substrate materials scans' accuracy, although the results show variability among IOS systems. When comparisons were done among IOS systems updated with the latest software version, best performers for complete arch trueness were the Emerald S, Trios 3, and Primescan systems. Conclusion: Software updates have a statistically significant effect on the trueness and precision of different IOS systems. These updates can have both positive and negative effects on scan accuracy, although it appears that these variations are within the clinical acceptability levels. (Quintessence Int 2021;52:636-644; doi: 10.3290/j.qi.b1098315)
引用
收藏
页码:636 / 644
页数:9
相关论文
共 41 条
  • [1] Accuracy of casts produced from conventional and digital workflows: A qualitative and quantitative analyses
    Abduo, Jaafar
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2019, 11 (02) : 138 - 146
  • [2] Accuracy of Intraoral Scanners: A Systematic Review of Influencing Factors
    Abduo, Jaafar
    Elseyoufi, Mohamed
    [J]. EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2018, 26 (03) : 101 - 121
  • [3] Digital Versus Conventional Impressions in Fixed Prosthodontics: A Review
    Ahlholm, Pekka
    Sipila, Kirsi
    Vallittu, Pekka
    Jakonen, Minna
    Kotiranta, Ulla
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (01): : 35 - 41
  • [4] Marginal and Internal Discrepancies Related to Margin Design of Ceramic Crowns Fabricated by a CAD/CAM System
    Assuncao Souza, Rodrigo Othavio
    Ozcan, Mutlu
    Pavanelli, Carlos Augusto
    Buso, Leonardo
    Leao Lombardo, Geraldo Henrique
    Araujo Michida, Silvia Masae
    Melo Mesquita, Alfredo Mikail
    Bottino, Marco Antonio
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2012, 21 (02): : 94 - 100
  • [5] Effect of scan substrates on accuracy of 7 intraoral digital impression systems using human maxilla model
    Bocklet, Chris
    Renne, Walter
    Mennito, Anthony
    Bacro, Thierry
    Latham, Jason
    Evans, Zachary
    Ludlow, Mark
    Kelly, Abigail
    Nash, Jansen
    [J]. ORTHODONTICS & CRANIOFACIAL RESEARCH, 2019, 22 : 168 - 174
  • [6] Digital workflow for articulating maxillary and mandibular 3D arch models using an open source 3D modeling software program
    Buzayan, Muaiyed Mahmoud
    Seong, Lim Ghee
    Elkezza, Aeman
    Abidin, Zubaidah Bt Zanul
    Yunus, Norsiah Binti
    Sivakumar, Indumathi
    [J]. QUINTESSENCE INTERNATIONAL, 2020, 51 (09): : 776 - 779
  • [7] Longitudinal Analysis of CAD/CAM Restoration Incorporation Rates into Navy Dentistry
    Dickens, Noel
    Haider, Humza
    Lien, Wen
    Simecek, John
    Stahl, Jonathan
    [J]. MILITARY MEDICINE, 2019, 184 (5-6) : E365 - E372
  • [8] Validation of an optical system to measure acetabular shell deformation in cadavers
    Dold, Philipp
    Bone, Martin C.
    Flohr, Markus
    Preuss, Roman
    Joyce, Tom J.
    Deehan, David
    Holland, James
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2014, 228 (08) : 781 - 786
  • [9] The effect different substrates have on the trueness and precision of eight different intraoral scanners
    Dutton, Ethan
    Ludlow, Mark
    Mennito, Anthony
    Kelly, Abigail
    Evans, Zachary
    Culp, Alexander
    Kessler, Raymond
    Renne, Walter
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2020, 32 (02) : 204 - 218
  • [10] Ender A, 2019, INT J COMPUT DENT, V22, P11