Multi-criterion comparison of compression and absorption heat pumps for ultra-low grade waste heat recovery

被引:44
作者
Xu, Z. Y. [1 ]
Gao, J. T. [1 ]
Hu, Bin [1 ]
Wang, R. Z. [1 ]
机构
[1] Shanghai Jiao Tong Univ, MOE, Engn Res Ctr Solar Power & Refrigerat, Inst Refrigerat & Cryogen, Shanghai 200240, Peoples R China
关键词
Waste heat; Compression; Absorption; Heat pump; Exergy; ADSORPTION REFRIGERATION; THERMODYNAMIC PROPERTIES; FORMULATION; SIMULATION;
D O I
10.1016/j.energy.2021.121804
中图分类号
O414.1 [热力学];
学科分类号
摘要
Heat pump is effective to recover ultra-low grade waste heat, and includes compression and absorption heat pumps. However, the driving source of these heat pumps are different. This makes the efficiency comparison unfair, and multi-criterion comparison is necessary. In this paper, the compression and absorption heat pumps are compared under the same condition, where 30 degrees C waste heat is recovered to provide 60 degrees C domestic heating supply. Analyses with coefficient of performance (COP), second law efficiency, exergy efficiency and exergy rate are carried out. Exergy-to-energy ratio of driving source, instead of temperature, is used to unify the evaluation of different driving sources. Results show that compression heat pump has higher COP but lower exergy efficiency, indicating more irreversible loss. This is followed by double effect, single effect and double lift absorption heat pumps. The high COP lead to effective recovery of exergy from waste heat, with higher exergy rate. However, the strong sensitivity of COP versus temperature lift in compression heat pump makes it more effective under small temperature lift, while absorption heat pumps are more effective under higher temperature lift. The multi criterion comparisons provide both deeper understanding about heat pumps and useful framework for waste heat recovery analysis. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:12
相关论文
共 36 条
[1]  
Averfalk H, 2014, ANNEX 35 APPL IND HE
[2]   Low grade waste heat recovery with subcritical and supercritical Organic Rankine Cycle based on natural refrigerants and their binary mixtures [J].
Braimakis, Konstantinos ;
Preissinger, Markus ;
Brueggemann, Dieter ;
Karellas, Sotirios ;
Panopoulos, Kyriakos .
ENERGY, 2015, 88 :80-92
[3]   Methods to estimate the industrial waste heat potential of regions - A categorization and literature review [J].
Brueckner, Sarah ;
Miro, Laia ;
Cabeza, Luisa F. ;
Pehnt, Martin ;
Laevemann, Eberhard .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 38 :164-171
[4]   Dynamic modeling and simulation of a double-effect absorption heat pump [J].
de la Calle, Alberto ;
Roca, Lidia ;
Bonilla, Javier ;
Palenzuela, Patricia .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 72 :171-191
[5]   Multi-criteria exergy based optimization of an Organic Rankine Cycle for waste heat recovery in the cement industry [J].
Fergani, Zineb ;
Touil, Djamel ;
Morosuk, Tatiana .
ENERGY CONVERSION AND MANAGEMENT, 2016, 112 :81-90
[6]   Enlarged temperature lift of hybrid compression-absorption heat transformer via deep thermal coupling [J].
Gao, J. T. ;
Xu, Z. Y. ;
Wang, R. Z. .
ENERGY CONVERSION AND MANAGEMENT, 2021, 234
[7]   Experimental study on a double-stage absorption solar thermal storage system with enhanced energy storage density [J].
Gao, J. T. ;
Xu, Z. Y. ;
Wang, R. Z. .
APPLIED ENERGY, 2020, 262
[8]  
Gao JT, 2021, AIR SOURCE HYBRID AB, V291, DOI [10.1016/ j.apenergy.2021.116810, DOI 10.1016/J.APENERGY.2021.116810]
[9]   Exergy analysis of multi-effect water-LiBr absorption systems: From half to triple effect [J].
Gebreslassie, Berhane H. ;
Medrano, Marc ;
Boer, Dieter .
RENEWABLE ENERGY, 2010, 35 (08) :1773-1782
[10]   Review of heat pump systems for drying application [J].
Goh, Li Jin ;
Othman, Mohd Yusof ;
Mat, Sohif ;
Ruslan, Hafidz ;
Sopian, Kamaruzzaman .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (09) :4788-4796