Monitoring platelet dependent thrombin generation in mice

被引:22
作者
Dargaud, Yesim [1 ,2 ,3 ]
Spronk, Henri M. H. [2 ,3 ]
Leenders, Peter [2 ,3 ]
Hemker, H. Coenraad [4 ]
Ten Cate, Hugo [2 ,3 ]
机构
[1] Univ Lyon 1, Unite Hemostase Clin, Hop Edouard Herriot, F-69003 Lyon, France
[2] Maastricht Univ, Lab Clin Thrombosis & Haemostasis, Dept Internal Med, Maastricht, Netherlands
[3] Maastricht Univ, Cardiovasc Res Inst Maastricht, Maastricht, Netherlands
[4] Synapse Bv, Cardiovasc Res Inst Maastricht, Maastricht, Netherlands
关键词
Thrombin generation; Mouse; Platelet; Corn trypsin inhibitor; Activated protein C resistance; CALIBRATED AUTOMATED THROMBOGRAPHY; MOUSE PLASMA; COAGULATION;
D O I
10.1016/j.thromres.2010.08.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Calibrated automated thrombin generation assay was adapted to measure thrombin generation in platelet rich plasma from mice. Vena cava phlebotomy appeared the best technique for blood sampling. The concentration-effect curves of tissue factor and platelet count have been determined. Corn trypsin inhibitor 2 mu M inhibits contact activation effectively. Recombinant human thrombomodulin does not inhibit thrombin generation in mouse plasma but activated protein C (20 nM) does. Thrombin generation was dose dependently diminished by low molecular weight heparin and increased by high concentrations of exogenous factor VIII i.e. the assay can detect both hypo-and hypercoagulability. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:436 / 441
页数:6
相关论文
共 18 条
[1]   Fixed dosage of low-molecular-weight heparins causes large individual variation in coagulability, only partly correlated to body weight [J].
Al Dieri, R ;
Alban, S ;
Bégun, S ;
Hemker, HC .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2006, 4 (01) :83-89
[2]   The measurement and application of thrombin generation [J].
Baglin, T .
BRITISH JOURNAL OF HAEMATOLOGY, 2005, 130 (05) :653-661
[3]  
CATALFAMO JL, 1989, METHOD ENZYMOL, V169, P27
[4]   Elimination of contact factor activation improves measurement of platelet-dependent thrombin generation by calibrated automated thrombography at low-concentration tissue factor [J].
Dargaud, Y ;
Luddington, R ;
Baglin, TP .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2006, 4 (05) :1160-1161
[5]   The technique of measuring thrombin generation with fluorogenic substrates: 3. The effects of sample dilution [J].
De Smedt, Erik ;
Wagenvoord, Rob ;
Hemker, H. Coen .
THROMBOSIS AND HAEMOSTASIS, 2009, 101 (01) :165-170
[6]   NANO-SCALE DENSITOMETRIC QUANTITATION OF PHOSPHOLIPIDS [J].
HEDEGAARD, E ;
JENSEN, B .
JOURNAL OF CHROMATOGRAPHY, 1981, 225 (02) :450-454
[7]   The technique of measuring thrombin generation with fluorescent substrates: 4. The H-transform, a mathematical procedure to obtain thrombin concentrations without external calibration [J].
Hemker, H. Coen ;
Hemker, Pieter W. ;
Al Dieri, Raed .
THROMBOSIS AND HAEMOSTASIS, 2009, 101 (01) :171-177
[8]  
Hemker HC, 2000, THROMB HAEMOSTASIS, V84, P747
[9]   Calibrated automated thrombin generation measurement in clotting plasma [J].
Hemker, HC ;
Giesen, P ;
Al Dieri, R ;
Regnault, V ;
de Smedt, E ;
Wagenvoord, R ;
Lecompte, T ;
Béguin, S .
PATHOPHYSIOLOGY OF HAEMOSTASIS AND THROMBOSIS, 2003, 33 (01) :4-15
[10]   Mouse models in coagulation [J].
Hogan, KA ;
Weiler, H ;
Lord, ST .
THROMBOSIS AND HAEMOSTASIS, 2002, 87 (04) :563-574