The impact of atrial fibrillation on accuracy of oscillometric blood pressure measurement: effect of ventricular rate

被引:18
作者
Xie, Feng [1 ]
Xu, Jingsong [1 ]
Xia, Ling-lin [2 ]
Luo, Xiao [1 ]
Jiang, Zhenzhen [1 ]
Wu, Yanqing [1 ]
Su, Hai [1 ]
机构
[1] Nanchang Univ, Affiliated Hosp 2, Dept Cardiovasc Med, Nanchang, Jiangxi, Peoples R China
[2] Nanchang Univ, Coll Software, Nanchang, Jiangxi, Peoples R China
关键词
Blood pressure; Accuracy; Oscillometric; Atrial fibrillation; Sinus rhythm; DEVICES;
D O I
10.1038/s41440-019-0386-4
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
This study evaluated the impact of ventricular rate (VR) in atrial fibrillation (AF) patients with oscillometric BP measurements. This study included 138 patients with AF and 112 patients with sinus rhythm (SR) who underwent coronary angiography. Left arm BP was measured three times with an oscillometric device, and the average was recorded as the final oscillometric value. At the same time, the average of three intra-aortic BP readings was used as invasive values. Delta BP was the difference between intra-aortic and oscillometric BP. Meanwhile, the BP percentage difference (PD-BP) was calculated with the following formula: PD-BP = (delta BP/intra-aortic BP) x 100%. Based on the VR, four subgroups of AF and SR patients, <80, 80-99, 100-120, and >120 bpm, were created, and the mean PD-BP for both systolic blood pressure (SBP) and diastolic blood pressure (DBP) was significantly higher in the AF group than in the SR group. Moreover, the mean PD-SBP values gradually increased as VR increased in both groups. More importantly, the difference in PD-SBP between the AF and SR groups increased as VR increased: when VR was <80 bpm, the levels were similar (-2.0 +/- 3.5 vs. -1.4 +/- 2.7 mm Hg, NS), but these values in AF patients were significantly higher when VR was 80-99 bpm (-3.7 +/- 5.0 vs. -1.8 +/- 2.3 mm Hg, p < 0.05), 100-120 bpm (-6.1 +/- 4.3 vs. -2.3 +/- 1.9 mm Hg, p < 0.05) and >120 bpm (-7.8 +/- 4.9 vs. -2.9 +/- 1.7 mm Hg, p < 0.05). The accuracy of oscillometric BP measurements are dependent on the ventricular rate in AF patients even after three measurements, and a higher ventricular rate may result in larger underestimations of oscillometric BP.
引用
收藏
页码:518 / 524
页数:7
相关论文
共 19 条
[1]   Oscillometric blood pressure: a review for clinicians [J].
Alpert, Bruce S. ;
Quinn, David ;
Gallick, David .
JOURNAL OF THE AMERICAN SOCIETY OF HYPERTENSION, 2014, 8 (12) :930-938
[2]   Optimal Blood Pressure in Patients With Atrial Fibrillation (from the AFFIRM Trial) [J].
Badheka, Apurva O. ;
Patel, Nileshkumar J. ;
Grover, Peeyush M. ;
Shah, Neeraj ;
Patel, Nilay ;
Singh, Vikas ;
Deshmukh, Abhishek J. ;
Mehta, Kathan ;
Chothani, Ankit ;
Savani, Ghanshyambhai T. ;
Arora, Shilpkumar ;
Rathod, Ankit ;
Marzouka, George R. ;
Lafferty, James ;
Mehta, Jawahar L. ;
Mitrani, Raul D. .
AMERICAN JOURNAL OF CARDIOLOGY, 2014, 114 (05) :727-736
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Atrial fibrillation does not affect ankle-brachial index measured using the Doppler method [J].
Dabrowski, Michal ;
Lewandowski, Jacek ;
Abramczyk, Piotr ;
Lon, Izabela ;
Gaciong, Zbigniew ;
Sinski, Maciej .
HYPERTENSION RESEARCH, 2018, 41 (01) :60-65
[5]   Ambulatory blood pressure monitoring in elderly patients with chronic atrial fibrillation: is it absolutely contraindicated or a useful tool in clinical practice and research? [J].
Giantin, Valter ;
Perissinotto, Egle ;
Franchin, Alessandro ;
Baccaglini, Kareen ;
Attanasio, Francesca ;
Maselli, Monica ;
Grosso, Giorgia ;
Corradin, Maria Luisa ;
Tramontano, Alessandra ;
Manzato, Enzo .
HYPERTENSION RESEARCH, 2013, 36 (10) :889-894
[6]  
Kirchhof P, 2016, EUROPACE, V18, DOI [10.1093/europace/euw295, 10.5603/KP.2016.0172, 10.1016/j.rec.2016.11.033]
[7]   Automated measurement of office, home and ambulatory blood pressure in atrial fibrillation [J].
Kollias, Anastasios ;
Stergiou, George S. .
CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 2014, 41 (01) :9-15
[8]   Differences in Heart Rate Response and Recovery After 6-Minute Walk Test Between Patients With Atrial Fibrillation and in Sinus Rhythm [J].
Luo, Xiao ;
Xiong, Qinmei ;
Xu, Jingsong ;
Hong, Kui ;
Peng, Qiang ;
Li, Juxiang ;
Cheng, Xiaoshu ;
Lip, Gregory Y. H. ;
Hai, Su .
AMERICAN JOURNAL OF CARDIOLOGY, 2018, 122 (04) :592-596
[9]   Reliability of Oscillometric Blood Pressure Monitoring in Atrial Fibrillation Patients Admitted for Electric Cardioversion [J].
Maselli, Monica ;
Giantin, Valter ;
Corrado, Domenico ;
Franchin, Alessandro ;
Attanasio, Francesca ;
Pengo, Valentina ;
Tramontano, Alessandra ;
De Toni, Pietro ;
Perissinotto, Egle ;
Manzato, Enzo .
JOURNAL OF CLINICAL HYPERTENSION, 2015, 17 (07) :558-564
[10]   Should Oscillometric Blood Pressure Monitors Be Used in Patients With Atrial Fibrillation? [J].
Myers, Martin G. ;
Stergiou, George S. .
JOURNAL OF CLINICAL HYPERTENSION, 2015, 17 (07) :565-566