Double solar screens for window to control sunlight in Kuwait

被引:9
作者
Alawadhi, Esam M. [1 ]
机构
[1] Kuwait Univ, Dept Mech Engn, POB 5969, Safat 13060, Kuwait
关键词
Window; Solar screen; An illuminance level; Heat flow; Solar energy; RESIDENTIAL DESERT BUILDINGS; DAYLIGHTING PERFORMANCE; THERMAL COMFORT; ENERGY; DESIGN; IMPACT; AVAILABILITY; VALIDATION; SHADES; GLARE;
D O I
10.1016/j.buildenv.2018.08.058
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This research experimentally investigates the concept of double solar screens installed on the external side of a window. The aim of the double solar screens is to control the amount of sunlight entering the indoor space to tackle the negative side effect of sunlight. Two identical perforated screens with square holes are considered, and the perforation ratio of each screen is 25%. Different installation arrangements of the two screens with respect to their holes' misalignment are considered. For comparison purposes, a window without a solar screen and with a single solar screen is considered in the study. The measurements are conducted in mid -June, and screens are installed on the West facing fa ade window. Without the solar screens, there is significant illuminance level diversity in the indoor space, and it varies between 200 and 13,810 Lux. With a single solar, the indoor illuminance level is decreased by 90%, and the heat flow through the window is decreased by 27.1%. If a second solar screen is installed, the illuminance level varies between 175 and 200 Lux, and the heat flow is reduced between 36.1% and 52.5%, depending on the misalignment of the screens holes. In term of illuminance, solar screens with down misaligned holes show the best performance, while the solar screens with right misaligned holes provide the highest heat flow reduction. The overall performance of double solar screens with down misaligned holes is the optimum in term of the illuminance and heat flow reduction through the window.
引用
收藏
页码:392 / 401
页数:10
相关论文
共 27 条
[1]   Window design in architecture: Analysis of energy savings for lighting and visual comfort in residential spaces [J].
Acosta, Ignacio ;
Angel Campano, Miguel ;
Francisco Molina, Juan .
APPLIED ENERGY, 2016, 168 :493-506
[2]   The traditional Yemeni window and natural lighting [J].
Ayssa, AZ .
RENEWABLE ENERGY, 1996, 8 (1-4) :214-218
[3]   Investigating the thermal behavior of double-skin perforated sheet facades: Part A: Model characterization and validation procedure [J].
Blanco, Jesus M. ;
Arriaga, Pedro ;
Roji, Eduardo ;
Cuadrado, Jesus .
BUILDING AND ENVIRONMENT, 2014, 82 :50-62
[4]   Active dynamic windows for buildings: A review [J].
Casini, Marco .
RENEWABLE ENERGY, 2018, 119 :923-934
[5]  
DiLaura DL., 2011, LIGHTING HDB, VTenth
[6]   Impact of external shading devices on thermal and daylighting performance of offices in hot climate regions [J].
Freewan, Ahmed A. Y. .
SOLAR ENERGY, 2014, 102 :14-30
[7]   Optimizing complex building design for annual daylighting performance and evaluation of optimization algorithms [J].
Futrell, Benjamin J. ;
Ozelkan, Ertunga C. ;
Brentrup, Dale .
ENERGY AND BUILDINGS, 2015, 92 :234-245
[8]   Study on distributed individuation lighting model and analysis to energy consumption character [J].
Gao Yingming ;
Xu Mingdong ;
Zhang Huanyue ;
Guo Xu ;
Li Ping ;
Zou Nianyu .
ENERGY AND BUILDINGS, 2017, 151 :45-52
[9]   The energy savings potential of using dynamic external louvers in an office building [J].
Hammad, Fawwaz ;
Abu-Hijleh, Bassam .
ENERGY AND BUILDINGS, 2010, 42 (10) :1888-1895
[10]   Numerical and experimental validation for the thermal transmittance of windows with cellular shades [J].
Hart, Robert .
ENERGY AND BUILDINGS, 2018, 166 :358-371