Feasibility and Limitations of an Automated 2D-3D Rigid Image Registration System for Complex Endovascular Aortic Procedures

被引:39
作者
Carrell, Tom W. G. [1 ,2 ,3 ]
Modarai, Bijan [1 ,2 ,3 ]
Brown, James R. I. [2 ,4 ]
Penney, Graeme P. [2 ,3 ]
机构
[1] Guys & St Thomas NHS Fdn Trust, London SE1 7EH, England
[2] Kings Hlth Partners, London, England
[3] Kings Coll London, London WC2R 2LS, England
[4] Kings Coll Hosp, London, England
基金
英国工程与自然科学研究理事会;
关键词
navigation; image registration; endovascular aneurysm repair; aortic aneurysm; computed tomography; digital subtraction angiography; fluoroscopy; ANEURYSM REPAIR; EXPERIENCE;
D O I
10.1583/09-2987MR.1
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To examine the feasibility of an automated 2-dimensional (2D) to 3- dimensional (3D) image registration system to simplify the navigational challenges faced in complex endovascular aortic procedures. Methods: An automated 2D-3D image registration system was used to overlay pre-acquired 3D computed tomography images onto fluoroscopy images taken during endovascular aneurysm repair. Errors between the 3D overlay and digital subtraction angiograms were measured and correlated with aortic neck angulation. A mean discrepancy <= 3 mm was considered clinically acceptable. Results: There was a strong correlation between maximum neck angulation and maximum registration error (Pearson's r=0.75). Aortas with a maximum neck angulation 5300 had a mean error of 2.5 +/- 1.2 mm, whereas aortas with neck angulation >30 degrees had a mean error of 6.2 +/- 2.5 mm (p<0.0001). Conclusion: The major source of registration errors is aortic deformation caused by the presence of the introducer and endovascular graft. Further work is required if this technology is to be routinely applied to severely angulated aortic anatomy. J Endovasc Ther. 2010;17:527-533
引用
收藏
页码:527 / 533
页数:7
相关论文
共 14 条
  • [11] Thirty-day mortality statistics underestimate the risk of repair of thoracoabdominal aortic aneurysms: A statewide experience
    Rigberg, DA
    McGory, ML
    Zingmond, DS
    Maggard, MA
    Agustin, M
    Lawrence, PF
    Ko, CY
    [J]. JOURNAL OF VASCULAR SURGERY, 2006, 43 (02) : 217 - 222
  • [12] Endovascular treatment of thoracoabdominal aortic aneurysms
    Roselli, Eric E.
    Greenberg, Roy K.
    Pfaff, Kathryn
    Francis, Catherine
    Svensson, Lars G.
    Lytle, Bruce W.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 133 (06) : 1474 - 1481
  • [13] Present and Future of Branched Stent Grafts in Thoraco-abdominal Aortic Aneurysm Repair: A Single-centre Experience
    Verhoeven, E. L.
    Tielliu, I. F.
    Bos, W. T.
    Zeebregts, C. J.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2009, 38 (02) : 155 - 161
  • [14] Results of Endovascular Repair of Abdominal Aortic Aneurysms with an Unfavorable Proximal Neck Using Large Stent-Grafts
    Zayed, Hany A.
    Bell, Rachel E.
    Clough, Rachel E.
    Thomas, Stephen
    Sabharwal, Tarun
    Reidy, John F.
    Carrell, Tom W.
    Taylor, Peter R.
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 32 (06) : 1161 - 1164