Methodological and technological implications of quantitative human movement analysis in long term space flights

被引:19
作者
Ferrigno, G [1 ]
Baroni, G [1 ]
Pedotti, A [1 ]
机构
[1] Politecn Milan, Fdn Pro Juventute Don Carlo Gnocchi, Dipartimento Bioingn, Milan, Italy
关键词
human motion analysis; 3-D reconstruction; manned orbital modules; life science; microgravity;
D O I
10.1016/S0021-9290(98)00175-4
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In the frame of the 179-days EUROMIR `95 space mission, two in-flight experiments foresaw the analysis of three-dimensional human movements in microgravity. For this aim, a space qualified opto-electronic motion analyser based on passive markers was installed onboard the MIR Space Station. The paper describe's the experimental procedures designed in order to face technical and operational limitations imposed by the critical environment of the orbital module. The reliability of the performed analysis is discussed, focusing two related aspects: accuracy in three-dimensional marker localisation and data comparability among different experimental sessions. The effect of the critical experimental set-up and of TV cameras optical distortions is evaluated on in-flight acquired data, by performing an analysis on Euclidean distance conservation on rigid bodies. An optimisation method for the recovering of a unique reference frame throughout the whole mission is described. Results highlight the potentiality that optoelectronics and close-range photogrammetry have for automatic motion analysis onboard orbital modules. The discussion of the obtained results provides general suggestions for the implementation of experimental human movement analysis in critical environments, based on the suitable trade-off between external constraints and achievable analysis reliability. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:431 / 436
页数:6
相关论文
共 20 条
[1]  
[Anonymous], ASP S CLOS RANG PHOT
[2]  
Baron MH, 1996, GENE EXPRESSION, V6, P129
[3]  
Baroni G, 1997, INT CONGR SER, V1144, P278
[4]  
BARONI G, 1998, IN PRESS MICROGRAVIT, V7
[5]   Statistical comparison of DLT versus ILSSC in the calibration of a photogrammetric stereo-system [J].
Borghese, NA ;
Cerveri, P ;
Ferrigno, GC .
JOURNAL OF BIOMECHANICS, 1997, 30 (04) :409-413
[6]   ACCURACY ASSESSMENT AND CONTROL POINT CONFIGURATION WHEN USING THE DLT FOR PHOTOGRAMMETRY [J].
CHALLIS, JH ;
KERWIN, DG .
JOURNAL OF BIOMECHANICS, 1992, 25 (09) :1053-1058
[7]   STRATIFICATION OF 3-DIMENSIONAL VISION - PROJECTIVE, AFFINE, AND METRIC REPRESENTATIONS [J].
FAUGERAS, O .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1995, 12 (03) :465-484
[8]   PATTERN-RECOGNITION IN 3D AUTOMATIC HUMAN MOTION ANALYSIS [J].
FERRIGNO, G ;
BORGHESE, NA ;
PEDOTTI, A .
ISPRS JOURNAL OF PHOTOGRAMMETRY AND REMOTE SENSING, 1990, 45 (04) :227-246
[9]   ELITE - A DIGITAL DEDICATED HARDWARE SYSTEM FOR MOVEMENT ANALYSIS VIA REAL-TIME TV SIGNAL-PROCESSING [J].
FERRIGNO, G ;
PEDOTTI, A .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (11) :943-950
[10]  
Ferrigno G., 1995, 3 DIMENSIONAL ANAL H, P57