Laboratory-Scale Experimental Setup for Studying Cable Dampers

被引:10
作者
Chen, Lin [1 ]
Sun, Limin [2 ]
机构
[1] Tongji Univ, Dept Bridge Engn, Shanghai 200092, Peoples R China
[2] Tongji Univ, State Key Lab Disaster Reduct Civil Engn, Shanghai 200092, Peoples R China
关键词
Cables; Beams; Vibration; Dynamic properties; Equivalence; Full-scale tests; Laboratory tests; TAUT-CABLE; VIBRATION MITIGATION; INTERMEDIATE DAMPER; SEMIACTIVE CONTROL; TENSIONED BEAMS; ATTACHED DAMPER; STAY CABLES; BRIDGE; FORMULATION; SYSTEMS;
D O I
10.1061/(ASCE)EM.1943-7889.0000878
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This study proposes a laboratory-scale experimental setup that simulates the dynamics of a full-scale stay cable with a transverse damper, allowing the full-scale performance of different types of dampers to be evaluated and compared in a laboratory setting. This test scheme resembles hybrid testing in that it retains the physical structural component for experiments, whereas it uses an equivalent model to represent the large-scale main structure instead of the numerical simulation used in a hybrid test. For the cable, a feasible model is presented that is composed of two flexible beams that are suspended vertically, fixed at their upper ends, and connected at their lower ends by a rigid mass; the damper is attached transversely to one of the beams. The setup is modeled as tensioned beams for clamped-guided supports with a terminal mass and an intermediate damper for dynamic analysis, and the characteristic equation is formulated from dynamic-stiffness matrices of beam segments. Modal properties of the setup are found to be similar to those of a cable-damper system, based on which the equivalence conditions are presented. The established equivalence between a cable and a model is further found to be roughly independent of damper properties for practical applications, therefore ascertaining the potential of this setup for a cable-damper study. Experiments have also been conducted in which the damper performance is evaluated on a full-scale cable and on a beam-mass assembly designed to represent the first vibration mode of the stay cable. The amplitude-dependent damping ratios achieved in the laboratory setting are found to be comparable to those achieved for the full-scale cable, suggesting the applicability and effectiveness of this experimental setup. (C) 2014 American Society of Civil Engineers.
引用
收藏
页数:16
相关论文
共 50 条
[1]  
Caetano Ede Sa., 2007, STRUCTURAL ENG DOCUM, V9
[2]   Passive hybrid technique for the vibration mitigation of systems of interconnected stays [J].
Caracoglia, Luca ;
Jones, Nicholas P. .
JOURNAL OF SOUND AND VIBRATION, 2007, 307 (3-5) :849-864
[3]   Damping of taut-cable systems: Two dampers on a single stay [J].
Caracoglia, Luca ;
Jones, Nicholas P. .
JOURNAL OF ENGINEERING MECHANICS, 2007, 133 (10) :1050-1060
[4]   MR damping system on Dongting Lake cable-stayed bridge [J].
Chen, ZQ ;
Wang, XY ;
Ko, JM ;
Ni, YQ ;
Spencer, BF ;
Yang, G .
SMART STRUCTURES AND MATERIALS 2003: SMART SYSTEMS AND NONDESTRUCTIVE EVALUATION FOR CIVIL INFRASTRUCTURES, 2003, 5057 :229-235
[5]   Large-scale experimental verification of semiactive control through real-time hybrid simulation [J].
Christenson, Richard ;
Lin, Yi Zhong ;
Emmons, Andrew ;
Bass, Brent .
JOURNAL OF STRUCTURAL ENGINEERING, 2008, 134 (04) :522-534
[6]  
Clough R., 2003, DYNAMIC STRUCTURES
[7]   Stability and delay compensation for real-time substructure testing [J].
Darby, AP ;
Williams, MS ;
Blakeborough, A .
JOURNAL OF ENGINEERING MECHANICS, 2002, 128 (12) :1276-1284
[8]   Real-time substructure tests using hydraulic actuator [J].
Darby, AP ;
Blakeborough, A ;
Williams, MS .
JOURNAL OF ENGINEERING MECHANICS-ASCE, 1999, 125 (10) :1133-1139
[9]  
Elishakoff Isaac., 2004, EIGENVALUES INHOMOGE, V1st
[10]  
Fujino Y., 2012, Wind Resistant Design of Bridge in Japan: Developements and practices