An Open-End Winding Motor Approach to Mitigate the Phase Voltage Distortion on Multilevel Inverters

被引:45
作者
Foti, Salvatore [1 ]
Testa, Antonio [1 ]
Scelba, Giacomo [2 ]
De Caro, Salvatore [1 ]
Cacciato, Mario [2 ]
Scarcella, Giuseppe [2 ]
Scimone, Tommaso [1 ]
机构
[1] Univ Messina, Dept Engn, I-98122 Messina, Italy
[2] Univ Catania, Dept Elect Elect Engn & Comp Sci, I-95125 Catania, Italy
关键词
AC motor drives; active power filter; harmonic reduction; multilevel inverter (MLI); pulse width modulation (PWM); SELECTIVE HARMONIC ELIMINATION; OPTIMAL PULSEWIDTH MODULATION; SINGLE DC-LINK; INDUCTION-MOTOR; PWM INVERTER; CONVERTERS; DRIVE; SERIES;
D O I
10.1109/TPEL.2017.2695244
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An open-end winding machine configuration and a suitable control strategy for medium-voltage ac motor drives applications are proposed in this paper in order to reduce the distortion of phase voltages in multilevel inverters (MLIs). Differently than standard open-end winding configurations, where two inverters provide active power to both sides of the stator winding, a main MLI supplies in this case the machine on one side, while an auxiliary two-level inverter acts as active power filter on the other side. A high efficiency step modulation manages the MLI, while the auxiliary unit is pulse width modulation (PWM) operated. As the phase current harmonic content is improved, the torque ripple is reduced and the drive efficiency is increased. By exploiting the proposed approach, the apparent switching frequency of the system is that typical of a PWM inverter, although the main unit is operated according to a voltage step modulation strategy. Simulation and experimental results confirm the consistency of the proposed methodology.
引用
收藏
页码:2404 / 2416
页数:13
相关论文
共 49 条
[1]   Medium-Voltage Multilevel Converters-State of the Art, Challenges, and Requirements in Industrial Applications [J].
Abu-Rub, Haitham ;
Holtz, Joachim ;
Rodriguez, Jose ;
Ge Baoming .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (08) :2581-2596
[2]   On attaining the multiple solutions of selective harmonic elimination PWM three-level waveforms through function minimization [J].
Agelidis, Vassilios G. ;
Balouktsis, Anastasios I. ;
Cossar, Calum .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (03) :996-1004
[3]   Practical Experiences and Mitigation Methods of Harmonics in Wind Power Plants [J].
Badrzadeh, Babak ;
Gupta, Manoj .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2013, 49 (05)
[4]  
Baiju M. R., 2003, EPE Journal, V13, P29
[5]  
Baijua M. R., 2002, EUR POWER ELECT DRIV, V12, P59
[6]   Selective Harmonic Elimination in Asymmetric Cascaded Multilevel Inverters Using a New Low-frequency Strategy for Photovoltaic Applications [J].
Bakhshizadeh, Mohammad Kazem ;
Iman-Eini, Hossein ;
Blaabjerg, Frede .
ELECTRIC POWER COMPONENTS AND SYSTEMS, 2015, 43 (8-10) :964-969
[7]   GENERALIZED STRUCTURE OF A MULTILEVEL PWM INVERTER [J].
BHAGWAT, PM ;
STEFANOVIC, VR .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1983, 19 (06) :1057-1069
[8]   Multi-level inverters - A comparative study [J].
Bhuvaneswari, G ;
Nagaraju .
IETE JOURNAL OF RESEARCH, 2005, 51 (02) :141-153
[9]   Optimal Pulsewidth Modulation of a Dual Three-Level Inverter System Operated From a Single DC Link [J].
Boller, Till ;
Holtz, Joachim ;
Rathore, Akshay K. .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2012, 48 (05) :1610-1615
[10]  
Buccella C, 2014, 2014 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION (SPEEDAM), P73, DOI 10.1109/SPEEDAM.2014.6872070