机构:
Seoul Natl Univ, Dept Nucl Engn, 1 Gwanak Ro, Seoul 08826, South KoreaSeoul Natl Univ, Dept Nucl Engn, 1 Gwanak Ro, Seoul 08826, South Korea
Kim, Y. -G.
[1
]
Lee, J. -H.
论文数: 0引用数: 0
h-index: 0
机构:
Natl Fus Res Inst, 169-148 Gwahak Ro, Daejeon 34133, South KoreaSeoul Natl Univ, Dept Nucl Engn, 1 Gwanak Ro, Seoul 08826, South Korea
Lee, J. -H.
[2
]
Kim, D.
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ, Dept Nucl Engn, 1 Gwanak Ro, Seoul 08826, South KoreaSeoul Natl Univ, Dept Nucl Engn, 1 Gwanak Ro, Seoul 08826, South Korea
Kim, D.
[1
]
Yoo, M. -G.
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ, Dept Nucl Engn, 1 Gwanak Ro, Seoul 08826, South KoreaSeoul Natl Univ, Dept Nucl Engn, 1 Gwanak Ro, Seoul 08826, South Korea
Yoo, M. -G.
[1
]
Lee, H.
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ, Dept Nucl Engn, 1 Gwanak Ro, Seoul 08826, South KoreaSeoul Natl Univ, Dept Nucl Engn, 1 Gwanak Ro, Seoul 08826, South Korea
Lee, H.
[1
]
Hwang, Y. S.
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ, Dept Nucl Engn, 1 Gwanak Ro, Seoul 08826, South KoreaSeoul Natl Univ, Dept Nucl Engn, 1 Gwanak Ro, Seoul 08826, South Korea
Hwang, Y. S.
[1
]
Na, Y. -S.
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ, Dept Nucl Engn, 1 Gwanak Ro, Seoul 08826, South KoreaSeoul Natl Univ, Dept Nucl Engn, 1 Gwanak Ro, Seoul 08826, South Korea
Na, Y. -S.
[1
]
机构:
[1] Seoul Natl Univ, Dept Nucl Engn, 1 Gwanak Ro, Seoul 08826, South Korea
[2] Natl Fus Res Inst, 169-148 Gwahak Ro, Daejeon 34133, South Korea
来源:
JOURNAL OF INSTRUMENTATION
|
2017年
/
12卷
基金:
新加坡国家研究基金会;
关键词:
Nuclear instruments and methods for hot plasma diagnostics;
Plasma diagnostics - probes;
D O I:
10.1088/1748-0221/12/12/C12013
中图分类号:
TH7 [仪器、仪表];
学科分类号:
0804 ;
080401 ;
081102 ;
摘要:
The Thomson scattering system has been recently installed on Versatile Experiment Spherical Torus (VEST) to measure the electron temperature and the density of the core plasmas. Since the calibration of the system is required for the accurate measurement of these parameters, a polychromator and the system efficiency are calibrated. The bias voltage of the detector is optimized and the relative responsivity of the polychromator is measured to analyse the spectral broadening. The tendency of decreasing responsivity because of the ambient temperature change is addressed together. The efficiencies of the alignments using HeNe laser and Nd:YAG laser are compared. After the alignment using Rayleigh scattering, it is improved similar to 7 times while the peak signal of the stray light is decreased. To evaluate the efficiencies of the alignment using HeNe laser, it is compared with the efficiency of the fine alignment by Rayleigh scattering. After absolute calibration is done, the Thomson scattering signal is estimated theoretically. The Bayesian analysis is tried using the synthetic data, and the results show that the input temperature and the density are inside the contour of the 90% confident level. The calibrated Thomson scattering system will provide the meaningful information of the core plasma of the VEST.