Hemiarthroplasty or total hip arthroplasty in recent femoral neck fractures?

被引:101
作者
Guyen, Olivier [1 ]
机构
[1] CHU Vaudois, Hop Orthoped, Serv Orthoped Traumatol, Ave Pierre Decker 4, CH-1011 Lausanne, Switzerland
关键词
Intracapsular femoral neck fracture; Unipolar hemiarthroplasty; Bipolar hemiarthroplasty; Total hip arthroplasty; Dual-mobility implants; DISPLACED INTRACAPSULAR FRACTURE; 4-YEAR FOLLOW-UP; BIPOLAR HEMIARTHROPLASTY; INDEPENDENT PATIENTS; UNIPOLAR; REPLACEMENT; DISLOCATION; MULTICENTER; TRIAL; CUPS;
D O I
10.1016/j.otsr.2018.04.034
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The optimal treatment of recent femoral neck fractures remains debated. The available options are internal fixation, hemiarthroplasty (HA) and total hip arthroplasty (THA). There is a consensus in favour of internal fixation in younger patients. In elderly individuals who are institutionalised and have limited physical activity, HA is usually performed when the joint line is intact. Whether HA or THA deserves preference in patients aged 60 years or over is unclear. In addition, there are two types of HA, unipolar and bipolar, and two types of THA, conventional and dual-mobility. Both HA types provide similar outcomes with satisfactory stability but a risk of acetabular wear that may eventually require conversion to THA. THA is associated with better functional outcomes and a lower risk of revision surgery in self-sufficient, physically active patients. Instability is the leading complication of conventional THA and occurs with a higher incidence compared to HA. With all implant types, preoperative factors associated with mortality and complications include walking ability and level of self-sufficiency, nutritional status, and haematocrit. An evaluation of these factors before surgery is of paramount importance. Factors amenable to treatment should be corrected by working jointly with geriatricians to develop a preoperative management strategy. In patients who are self-sufficient, physically active, and free of risk factors, THA remains the option of choice, as it provides better functional outcomes. A dual-mobility implant deserves preference to prevent instability. HA is indicated in patients whose self-sufficiency and physical activity are limited. A unipolar implant should be used, as no evidence exists that bipolar implants provide additional benefits. When performing HA, the posterior approach should be avoided given the risk of instability. For THA, in contrast, the posterior approach is a reliable option in the hands of an experienced surgeon using a dual-mobility cup. Cement fixation of the stem is recommended to minimise the risk of peri-prosthetic fracture. (C) 2018 Published by Elsevier Masson SAS.
引用
收藏
页码:S95 / S101
页数:7
相关论文
共 35 条
[1]   Dual mobility cups hip arthroplasty as a treatment for displaced fracture of the femoral neck in the elderly. A prospective, systematic, multicenter study with specific focus on postoperative dislocation [J].
Adam, P. ;
Philippe, R. ;
Ehlinger, M. ;
Roche, O. ;
Bonnomet, F. ;
Mole, D. ;
Fessy, M. -H. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2012, 98 (03) :296-300
[2]   Total hip replacement and hemiarthroplasty in mobile, independent patients with a displaced intracapsular fracture of the femoral neck A SEVEN- TO TEN-YEAR FOLLOW-UP REPORT OF A PROSPECTIVE RANDOMISED CONTROLLED TRIAL [J].
Avery, P. P. ;
Baker, R. P. ;
Walton, M. J. ;
Rooker, J. C. ;
Squires, B. ;
Gargan, M. F. ;
Bannister, G. C. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (08) :1045-1048
[3]   Total hip arthroplasty and hemiarthroplasty in mobile, independent patients with a displaced intracapsular fracture of the femoral neck - A randomized, controlled trial [J].
Baker, R. P. ;
Squires, B. ;
Gargan, M. F. ;
Bannister, G. C. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (12) :2583-2589
[4]   Dual mobility cup reduces dislocation and re-operation when used to treat displaced femoral neck fractures [J].
Bensen, Anne S. ;
Jakobsen, Thomas ;
Krarup, Niels .
INTERNATIONAL ORTHOPAEDICS, 2014, 38 (06) :1241-1245
[5]   A randomised controlled trial comparing bipolar hemiarthroplasty with total hip replacement for displaced intracapsular fractures of the femoral neck in elderly patients [J].
Blomfeldt, R. ;
Tornkvist, H. ;
Eriksson, K. ;
Soderqvist, A. ;
Ponzer, S. ;
Tidermark, J. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (02) :160-165
[6]   Total hip arthroplasty versus hemiarthroplasty for displaced femoral neck fractures in the healthy elderly: a meta-analysis and systematic review of randomized trials [J].
Burgers, Paul T. P. W. ;
Van Geene, Arnoud R. ;
Van den Bekerom, Michel P. J. ;
Van Lieshout, Esther M. M. ;
Blom, Bastiaan ;
Aleem, Ilyas S. ;
Bhandari, M. ;
Poolman, Rudolf W. .
INTERNATIONAL ORTHOPAEDICS, 2012, 36 (08) :1549-1560
[7]   Dislocation of total hip replacement in patients with fractures of the femoral neck [J].
Enocson, Anders ;
Hedbeck, Carl-Johan ;
Tidermark, Jan ;
Pettersson, Hans ;
Ponzer, Sari ;
Lapidus, Lasse J. .
ACTA ORTHOPAEDICA, 2009, 80 (02) :184-189
[8]   The Cemented Unipolar Prosthesis for the Management of Displaced Femoral Neck Fractures in the Dependent Osteopenic Elderly [J].
Grosso, Matthew G. ;
Danoff, Jonathan R. ;
Padgett, Douglas E. ;
Iorio, Richard ;
Macaulay, William B. .
JOURNAL OF ARTHROPLASTY, 2016, 31 (05) :1040-1046
[9]   Hemiarthroplasty for Displaced Femoral Neck Fractures in the Elderly Has a Low Conversion Rate [J].
Grosso, Matthew J. ;
Danoff, Jonathan R. ;
Murtaugh, Taylor S. ;
Trofa, David P. ;
Sawires, Andrew N. ;
Macaulay, William B. .
JOURNAL OF ARTHROPLASTY, 2017, 32 (01) :150-154
[10]   Comparison of Bipolar Hemiarthroplasty with Total Hip Arthroplasty for Displaced Femoral Neck Fractures A Concise Four-Year Follow-up of a Randomized Trial [J].
Hedbeck, Carl Johan ;
Enocson, Anders ;
Lapidus, Gunilla ;
Blomfeldt, Richard ;
Tornkvist, Hans ;
Ponzer, Sari ;
Tidermark, Jan .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (05) :445-450