Digital radiography systems can be thought of as continuous linear shift-invariant systems followed by sampling. This view, along with the large number of pixels used for flat-panel systems, has motivated much of the work which attempts to extend figures of merit developed for analog systems, in particular noise equivalent quanta (NEQ) and detective quantum efficiency (DQE). A more general approach looks at the system as a continuous-to-discrete mapping and evaluates the signal-to-noise ratio (SNR) completely from the discrete data. In this paper, we study the effect of presampling blur on these figures of merit for a simple model that assumes that the background fluence is constant and that the blurring of the signal is deterministic. We find that for small signals, even in this idealized model, commonly used DQE/NEQ formulations do not accurately track the behavior of the fully digital SNR. Using these NEQ-based figures of merit would lead to different design decisions than using the ideal SNR. This study is meant to bring attention to the assumptions implicitly made when using Fourier methods. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:348 / 358
页数:11
相关论文
共 25 条
[1]   Linear response theory for detectors consisting of discrete arrays [J].
Albert, M ;
Maidment, ADA .
MEDICAL PHYSICS, 2000, 27 (10) :2417-2434
[2]  
[Anonymous], 1995, ELEMENTS SIGNAL DETE
[3]   Objective assessment of image quality. III. ROC metrics, ideal observers, and likelihood-generating functions [J].
Barrett, HH ;
Abbey, CK ;
Clarkson, E .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1998, 15 (06) :1520-1535
[4]   OBJECTIVE ASSESSMENT OF IMAGE QUALITY .2. FISHER INFORMATION, FOURIER CROSSTALK, AND FIGURES OF MERIT FOR TASK-PERFORMANCE [J].
BARRETT, HH ;
DENNY, JL ;
WAGNER, RF ;
MYERS, KJ .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1995, 12 (05) :834-852
[5]   Megalopinakophobia: Its symptoms and cures [J].
Barrett, HH ;
Myers, KJ ;
Gallas, B ;
Clarkson, E ;
Zhang, HB .
MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 :299-307
[6]  
Barrett HH., 2004, FDN IMAGE SCI
[7]   Analytical approximations to the Hotelling trace for digital x-ray detectors [J].
Clarkson, E ;
Pineda, AR ;
Barrett, HH .
MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 :339-349
[8]  
Cunningham I, 2000, HDB MED IMAGING, V1
[9]   EFFECTS OF UNDERSAMPLING ON THE PROPER INTERPRETATION OF MODULATION TRANSFER-FUNCTION, NOISE POWER SPECTRA, AND NOISE EQUIVALENT QUANTA OF DIGITAL IMAGING-SYSTEMS [J].
DOBBINS, JT .
MEDICAL PHYSICS, 1995, 22 (02) :171-181
[10]  
Fukunaga K., 1972, Introduction to statistical pattern recognition