Validity of the AHRQ Patient Safety Indicator "Central Venous Catheter-Related Bloodstream Infections"

被引:28
作者
Cevasco, Marisa [2 ,3 ]
Borzecki, Ann M. [4 ,5 ,7 ]
O'Brien, William J. [1 ]
Chen, Qi [1 ,4 ]
Shin, Marlena H. [1 ]
Itani, Kamal M. F. [2 ,5 ,6 ]
Rosen, Amy K. [1 ,4 ]
机构
[1] VA Boston Healthcare Syst, COLMR, Boston, MA 02130 USA
[2] VA Boston Healthcare Syst, Dept Surg, Boston, MA 02130 USA
[3] Brigham & Womens Hosp, Dept Surg, Boston, MA 02115 USA
[4] Boston Univ, Sch Publ Hlth, Dept Hlth Policy & Management, Boston, MA 02215 USA
[5] Boston Univ, Sch Med, Boston, MA 02215 USA
[6] Harvard Univ, Sch Med, Boston, MA USA
[7] Bedford VAMC, Ctr Hlth Qual Outcomes & Econ Res, Bedford, MA USA
关键词
D O I
10.1016/j.jamcollsurg.2011.02.005
中图分类号
R61 [外科手术学];
学科分类号
摘要
BACKGROUND: "Central venous catheter-related bloodstream infections" (CR-BSIs) is one of the patient safety indicators (PSI 7) developed by the Agency for Healthcare Research and Quality (AHRQ) to screen for potential safety events. We sought to investigate the validity of this PSI using the medical record as the gold standard. STUDY DESIGN: We conducted a retrospective cross-sectional study of all hospitalization records that met the criteria for PSI 7 within Veterans Health Administration (VA) hospitals from fiscal years 2003 to 2007. Trained abstractors used a standardized abstraction tool to review electronic medical records for the presence of a CR-BSI and the clinical circumstances surrounding the event. We determined the validity of this PSI by calculating its positive predictive value (PPV), and analyzed both true and false positive cases. RESULTS: Of 112 reviewed cases, 42 were true events of CR-BSIs, yielding a PPV of 38% (95% CI 29% to 47%). Seventy cases were false positives; these were attributed to correct ICD-9-CM codes but had diagnoses that fell outside the scope of the indicator (n = 28, 40%), coding inaccuracies (n = 21, 30%); and present on admission (POA) diagnoses (n = 21; 30%). Among the 42 patients with CR-BSIs, catheters were left in place for an average of 11 days, and 20% (n = 8) were placed in the femoral position. CONCLUSIONS: PSI 7 has relatively poor predictive ability for identifying true events. Coding-related issues were the main reason for the low PPV. Implementing POA codes and using more specific ICD-9-CM codes would improve its validity. As it currently stands, PSI 7 should not be used as a pay-for-performance measure, but should be limited to use in internal quality improvement efforts. (J Am Coll Surg 2011;212:984-990. (C) 2011 by the American College of Surgeons)
引用
收藏
页码:984 / 990
页数:7
相关论文
共 20 条
[1]  
*AHRQ, AG HEALTHC QUAL RES
[2]  
*AHRQ, 2003, AHRQ PAT SAF IND IN
[3]  
[Anonymous], AHRQ QUAL IND GUID P
[4]  
CEVASCO M, 2011, J AM COLL S IN PRESS
[5]   SYSTEMIC SEPSIS AND INTRAVENOUS DEVICES - A PROSPECTIVE SURVEY [J].
COLLIGNON, PJ ;
MUNRO, R ;
SORRELL, TC .
MEDICAL JOURNAL OF AUSTRALIA, 1984, 141 (06) :345-348
[6]  
GALLAGHER B, 2005, ADV PATIENT SAFETY F, V2
[7]   Validity of Selected Patient Safety Indicators: Opportunities and Concerns [J].
Kaafarani, Haytham M. A. ;
Borzecki, Ann M. ;
Itani, Kamal M. F. ;
Loveland, Susan ;
Mull, Hillary J. ;
Hickson, Kathleen ;
MacDonald, Sally ;
Shin, Marlena ;
Rosen, Amy K. .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2011, 212 (06) :924-934
[8]   Infection and Natural History of Emergency Department-Placed Central Venous Catheters [J].
LeMaster, Christopher H. ;
Schuur, Jeremiah D. ;
Pandya, Darshan ;
Pallin, Daniel J. ;
Silvia, Jennifer ;
Yokoe, Deborah ;
Agrawal, Ashish ;
Hou, Peter C. .
ANNALS OF EMERGENCY MEDICINE, 2010, 56 (05) :492-497
[9]   Quality of Traditional Surveillance for Public Reporting of Nosocomial Bloodstream Infection Rates [J].
Lin, Michael Y. ;
Hota, Bala ;
Khan, Yosef M. ;
Woeltje, Keith F. ;
Borlawsky, Tara B. ;
Doherty, Joshua A. ;
Stevenson, Kurt B. ;
Weinstein, Robert A. ;
Trick, William E. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2010, 304 (18) :2035-2041
[10]   NOSOCOMIAL BACTEREMIA - AN EPIDEMIOLOGIC OVERVIEW [J].
MAKI, DG .
AMERICAN JOURNAL OF MEDICINE, 1981, 70 (03) :719-732