Methylmercury determination in biota by solid-phase microextraction matrix effect evaluation

被引:24
作者
Carrasco, Luis [2 ]
Diez, Sergi [1 ]
Bayona, Josep M. [2 ]
机构
[1] CSIC, ICTJA, Environm Geol Dept, E-08028 Barcelona, Spain
[2] CSIC, IIQAB, Dept Environm Chem, E-08034 Barcelona, Spain
关键词
methylmercury; headspace SPME; matrix effects; biological samples; Py-AFS; standard addition calibration;
D O I
10.1016/j.chroma.2007.09.051
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Aqueous-phase alkylation followed by, headspace solid-phase microextraction (SPME) for mercury speciation in biota, was developed a decade ago. Despite this, matrix effects in this technique have not yet been addressed. In this paper, the importance of these effects has been assessed and overcome by standard addition calibration. Furthermore, improvements were made in the extraction of methylmercury (MeHg) from biological matrixes by optimizing the matrix digestion procedure (temperature and digestion time) and the SPME parameters (aliquot volume of digested samples, extraction temperature and fibre coating), which aimed to minimize the matrix effects. Accordingly, samples were alkaline digested (KOH, 25%, w/v, 60 degrees C, 180 min) and an aliquot was propylated using an aqueous NaBPr4 solution, headspace SPME sampling and, finally, by using GC-pyrolysis (Py)-atomic fluorescence spectrometry (AFS) determination. The procedure developed was validated using dogfish muscle reference material NRCC DORM-2. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:2 / 6
页数:5
相关论文
共 29 条
[1]  
Brito EMS, 1999, APPL ORGANOMET CHEM, V13, P487, DOI 10.1002/(SICI)1099-0739(199907)13:7<487::AID-AOC862>3.0.CO
[2]  
2-B
[3]   CAPILLARY COLUMN GAS-CHROMATOGRAPHY FOR MERCURY SPECIATION [J].
BULSKA, E ;
BAXTER, DC ;
FRECH, W .
ANALYTICA CHIMICA ACTA, 1991, 249 (02) :545-554
[4]  
Cai Y, 1998, APPL ORGANOMET CHEM, V12, P565, DOI 10.1002/(SICI)1099-0739(199808/09)12:8/9<565::AID-AOC762>3.0.CO
[5]  
2-K
[6]   Gas chromatographic determination of organomercury following aqueous derivatization with sodium tetraethylborate and sodium tetraphenylborate -: Comparative study of gas chromatography coupled with atomic fluorescence spectrometry, atomic emission spectrometry and mass spectrometry [J].
Cai, Y ;
Monsalud, S ;
Jaffé, R ;
Jones, RD .
JOURNAL OF CHROMATOGRAPHY A, 2000, 876 (1-2) :147-155
[7]   DETERMINATION OF METHYLMERCURY IN FISH AND RIVER WATER SAMPLES USING IN-SITU SODIUM TETRAETHYLBORATE DERIVATIZATION FOLLOWING BY SOLID-PHASE MICROEXTRACTION AND GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
CAI, Y ;
BAYONA, JM .
JOURNAL OF CHROMATOGRAPHY A, 1995, 696 (01) :113-122
[8]   Determination of methylmercury in fish using focused microwave digestion following by Cu2+ addition, sodium tetrapropylborate derivatization, n-heptane extraction, and gas chromatography-mass spectrometry [J].
Chen, SS ;
Chou, SS ;
Hwang, DF .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1024 (1-2) :209-215
[9]   Certification of methylmercury content in two fresh-frozen reference materials:: SRM 1947 Lake Michigan fish tissue and SRM 1974b organics in mussel tissue (Mytilus edulis) [J].
Davis, W. Clay ;
Christopher, S. J. ;
Pugh, Rebecca S. ;
Donard, O. F. X. ;
Krupp, Eva A. ;
Point, David ;
Horvat, Milena ;
Gibicar, D. ;
Kljakovic-Gaspic, Z. ;
Porter, Barbara J. ;
Schantz, Michele M. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (07) :2335-2341
[10]   An accurate and sensitive method for the determination of methylmercury in biological specimens using GC-ICP-MS with solid phase microextraction [J].
Davis, WC ;
Vander Pol, SS ;
Schantz, MM ;
Long, SE ;
Day, RD ;
Christopher, SJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (12) :1546-1551