Application of Simplex Optimization in the Development of an Automated online Preconcentration System for Manganese Determination

被引:14
作者
dos Santos, Queila O. [1 ]
Novaes, Cleber G. [1 ]
Bezerra, Marcos A. [1 ]
Lemos, Valfredo A. [1 ]
Moreno, Islania [1 ]
da Silva, Douglas G. [1 ]
dos Santos, Leandro [1 ]
机构
[1] Univ Estadual Sudoeste Bahia, Nucleo Quim Analit Bahia NQA, LQA, BR-45506191 Jequie, BA, Brazil
关键词
vegetal leaves; natural waters; simplex optimization; manganese; automated online preconcentration; SPECTROMETRIC DETERMINATION; FACTORIAL DESIGN; ABSORPTION; CADMIUM; SEPARATION; NICKEL; LEAD; IRON;
D O I
10.1590/S0103-50532010001200022
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
An automated procedure was developed to determine trace amounts of manganese from vegetal leaves and river waters using flame atomic absorption spectrometry (FAAS) after online preconcentration of this metal using an Amberlite XAD-4 minicolumn modified with 2-aminothiophenol. The preconcentration system is based on the solid-phase extraction of the metal into the minicolumn and elution with 0.30 mol L-1 hydrochloric acid, followed by its determination. Variables associated with the preconcentration system performance, such as pH, sampling flow rate and eluent concentration were optimized using a basic simplex as multivariate technique. The developed method provides an improvement factor of 14 along with limit of detection (3 sigma(B)) of 2.0 mu g L-1, and precision expressed as a 2.2% relative standard deviation (RSD%, n = 10, 30.0 mu g L-1). The procedure was applied to determine manganese in river waters collected from urban area of Jequie/Bahia. The accuracy of the procedure was checked by analysis of two certified reference materials (apple leaves, NIST 1515 and spinach leaves, NIST 1570). The developed procedure has been applied for manganese determination in vegetal leaves (chive, spinach, cauliflower and cabbage).
引用
收藏
页码:2340 / 2346
页数:7
相关论文
共 23 条
[1]   On-line system for preconcentration and determination of metals in vegetables by inductively coupled plasma optical emission Spectrometry [J].
Bezerra, Marcos A. ;
dos Santos, Walter N. L. ;
Lemos, Valfredo A. ;
Korn, Maria das Gracas A. ;
Ferreira, Sergio L. C. .
JOURNAL OF HAZARDOUS MATERIALS, 2007, 148 (1-2) :334-339
[2]  
Bruns R.E., 2006, Statistical Design-Chemometrics
[3]   MultiSimplex optimisation of the solid-phase microextraction-gas chromatographic-mass spectrometric determination of polycyclic aromatic hydrocarbons, polychlorinated biphenyls and phthalates from water samples [J].
Cortazar, E ;
Zuloaga, O ;
Sanz, J ;
Raposo, JC ;
Etxebarria, N ;
Fernández, LA .
JOURNAL OF CHROMATOGRAPHY A, 2002, 978 (1-2) :165-175
[4]   Development of a capillary zone electrophoresis method including a factorial design and simplex optimisation for analysis of amphetamine, amphetamine analogues, cocaine, and heroin [J].
Dahlén, J ;
von Eckardstein, S .
FORENSIC SCIENCE INTERNATIONAL, 2006, 157 (2-3) :93-105
[5]   Guidelines for calibration in analytical chemistry - Part 1. Fundamentals and single component calibration (IUPAC recommendations 1998) [J].
Danzer, K ;
Currie, LA .
PURE AND APPLIED CHEMISTRY, 1998, 70 (04) :993-1014
[6]   An automated on-line flow system for the pre-concentration and determination of lead by flame atomic absorption spectrometry [J].
Ferreira, SLC ;
Lemos, VA ;
Santelli, RE ;
Ganzarolli, E ;
Curtius, AJ .
MICROCHEMICAL JOURNAL, 2001, 68 (01) :41-46
[7]   Separation and preconcentration of cadmium ions in natural water using a liquid membrane system with 2-acetylpyridine benzoylhydrazone as carrier by flame atomic absorption spectrometry [J].
Granado-Castro, MD ;
Galindo-Riaño, MD ;
Garcìa-Vargas, M .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (04) :577-583
[8]   Development of a new sequential injection in-line cloud point extraction system for flame atomic absorption spectrometric determination of manganese in food samples [J].
Lemos, Valfredo Azevedo ;
Baliza, Patricia Xavier ;
de Carvalho, Anaildes Lago ;
Oliveira, Rafael Vasconcelos ;
Teixeira, Leonardo Sena Gomes ;
Bezerra, Marcos Almeida .
TALANTA, 2008, 77 (01) :388-393
[9]   Flow injection preconcentration system using a new functionalized resin for determination of cadmium and nickel in tobacco samples [J].
Lemos, Valfredo Azevedo ;
Novaes, Cleber Galvao ;
Lima, Adriana da Silva ;
Vieira, Daniel Rodrigues .
JOURNAL OF HAZARDOUS MATERIALS, 2008, 155 (1-2) :128-134
[10]   An on-line cloud point extraction system for flame atomic absorption spectrometric determination of trace manganese in food samples [J].
Lemos, Valfredo Azevedo ;
David, Graciete Teixeira .
MICROCHEMICAL JOURNAL, 2010, 94 (01) :42-47