Electrochemical Behaviour of Carbamazepine in Acetonitrile and Dimethylformamide Using Glassy Carbon Electrodes and Microelectrodes

被引:25
|
作者
Atkins, S. [1 ]
Sevilla, J. M. [2 ]
Blazquez, M. [2 ]
Pineda, T. [2 ]
Gonzalez-Rodriguez, J. [1 ]
机构
[1] Lincoln Univ, Sch Nat & Appl Sci, Lincoln LN6 7TS, England
[2] Univ Cordoba, Dept Quim Fis & Termodinam Aplicada, E-14071 Cordoba, Spain
关键词
Carbamazepine; Glassy carbon electrode; Microelectrodes; Voltammetry; LIQUID-CHROMATOGRAPHY; ELECTROREDUCTION; POLAROGRAPHY; METHANOL; SOLVENT; DRUGS;
D O I
10.1002/elan.201000341
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemical reduction of carbamazepine in acetonitrile (ACN) and dimethylformamide (DMF) using a glassy carbon electrode and microelectrodes has been studied. The reduction process is consistent with an electrochemical-chemical mechanism (EC) involving a two electron transfer followed by a first order reaction, as shown by the cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Half-wave potential, number of electron transferred, diffusion coefficient and rate constant of the associated chemical reaction are reported. Limits of detection (LOD) for DPV are 0.92 and 0.76 mg mL(-1) (3.89 x 10(-6) mol L-1 and 3.21 x 10(-6) mol L-1) in ACN and DMF, respectively. Precision (% RSD) and recovery (%) values when pharmaceutical compounds (200mg carbamazepine tablets) and spiked plasma samples were tested ranged from 1.09 to 9.04% and % recoveries ranged from 96 to 104.1%.
引用
收藏
页码:2961 / 2966
页数:6
相关论文
共 50 条
  • [1] Electrochemical Reduction of Carbamazepine in Ethanol and Water Solutions Using a Glassy Carbon Electrode
    Atkins, S.
    Jimenez-Perez, R.
    Sevilla, J. M.
    Blazquez, M.
    Pineda, T.
    Gonzalez-Rodriguez, J.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (02): : 2056 - 2068
  • [2] Electrochemical oxidation of benzaldehyde and hydroxybenzaldehydes in acetonitrile on platinum and glassy carbon electrodes
    Kiss, Laszlo
    Kunsagi-Mate, Sandor
    COMPTES RENDUS CHIMIE, 2019, 22 (08) : 557 - 561
  • [3] The electrochemical oxidation of thioselenanthrene in acetonitrile at conventional electrodes and microelectrodes
    Muller, R
    Lamberts, L
    Evers, M
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 417 (1-2): : 35 - 43
  • [4] ELECTROCHEMICAL OXIDATION OF SELENANTHRENE IN ACETONITRILE AT CONVENTIONAL ELECTRODES AND MICROELECTRODES
    MULLER, R
    LAMBERTS, L
    EVERS, M
    ELECTROCHIMICA ACTA, 1994, 39 (17) : 2507 - 2516
  • [5] Electrochemical behaviour and determination of niraparib using glassy carbon and boron-doped diamond electrodes
    Samanci, Seyda Nur
    Ozcelikay-Akyildiz, Goksu
    Atici, Esen Bellur
    Ozkan, Sibel A.
    DIAMOND AND RELATED MATERIALS, 2025, 152
  • [6] Electrochemical Redox Behaviour of Temozolomide Using a Glassy Carbon Electrode
    Ghalkhani, Masoumeh
    Fernandes, Isabel P. G.
    Oliveira, S. Carlos B.
    Shahrokhian, Saeed
    Oliveira-Brett, Ana Maria
    ELECTROANALYSIS, 2010, 22 (22) : 2633 - 2640
  • [7] Electrochemical determination of copper(II) using modified glassy carbon electrodes
    Bilici, Esra
    Yazicigil, Zafer
    Tok, Mutahire
    Oztekin, Yasemin
    DESALINATION AND WATER TREATMENT, 2012, 50 (1-3) : 198 - 205
  • [8] The electrochemical behaviour of novel multifunctional α-hydroxymethylated nitroalkenes at glassy carbon and wax impregnated carbon paste electrodes
    Mascarenhas, Ronald J.
    Namboothiri, Irishi N.
    Sherigara, Bailure S.
    Mahadevan, Kittappa M.
    CROATICA CHEMICA ACTA, 2007, 80 (01) : 53 - 59
  • [9] Electrochemical Behaviour of Isoflavones Genistein and Biochanin A at a Glassy Carbon Electrode
    Popa, Oana M.
    Diculescu, Victor C.
    ELECTROANALYSIS, 2013, 25 (05) : 1201 - 1208
  • [10] Electrochemical behaviour of isatin at a glassy carbon electrode
    Diculescu, Victor C.
    Kumbhat, Sunita
    Oliveira-Brett, Ana Maria
    ANALYTICA CHIMICA ACTA, 2006, 575 (02) : 190 - 197