Asthma symptoms among Chinese children: the role of ventilation and PM10 exposure at school and home

被引:16
作者
Fan, X-J. [1 ]
Yang, C. [1 ]
Zhang, L. [2 ]
Fan, Q. [2 ]
Li, T. [2 ]
Bai, X. [2 ]
Zhao, Z-H. [3 ]
Zhang, X. [2 ]
Norback, D. [4 ]
机构
[1] Taiyuan Univ Technol, Coll Chem & Chem Engn, Taiyuan, Shanxi, Peoples R China
[2] Shanxi Univ, Inst Environm Sci, Taiyuan, Shanxi, Peoples R China
[3] Fudan Univ, Sch Publ Hlth, Shanghai, Peoples R China
[4] Uppsala Univ, Dept Med Sci Occupat & Environm Med, Uppsala, Sweden
基金
瑞典研究理事会;
关键词
asthmatic symptoms; dampness; particulate matter; respiratory infections; school students; AIR-POLLUTION; RESPIRATORY SYMPTOMS; ALLERGEN LEVELS; INDOOR; QUALITY; OUTDOOR; PUPILS; ENVIRONMENT; PREVALENCE; RHINITIS;
D O I
10.5588/ijtld.17.0196
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
SETTING: Respiratory symptoms in relation to environment in Taiyuan, China. OBJECTIVE: To study associations between school/home exposure and prevalence of respiratory symptoms and self-reported respiratory infections (RIs) among students. DESIGN: A total of 2134 pupils from 10 schools answered a questionnaire; air pollution at school was measured. RESULTS: The prevalence of current wheeze, daytime attacks of breathlessness, nocturnal cough, nocturnal respiratory symptoms and RI was respectively 4.4%, 18.7%, 11.6%, 3.6% and 32.3%. Environmental tobacco smoke (ETS) at home was associated with daytime attacks of breathlessness (OR 1.41), nocturnal cough (OR 1.41) and RI (OR 1.26). Redecoration or indoor painting at home was associated with wheeze (OR 2.02), daytime attacks of breathlessness (OR 1.57) and nocturnal symptoms (OR 1.83). Dampness or mould at home was associated with daytime attacks of breathlessness (OR 1.68), nocturnal cough (OR 1.68) and RI (OR 1.69). Particulate matter of diameter <= 10 microns (PM10) in the classroom was associated with nocturnal cough (OR 1.20/10 mu g/m(3)). PM10 outside school was associated with daytime attacks of breathlessness (OR 1.07/10 mu g/m(3)) and nocturnal cough (OR 1.13/10 mu g/m(3)). Indoor carbon dioxide, a marker of poor ventilation (OR 1.52/1000 parts per million), and relative humidity (RH) (OR 1.33/10%) were associated with nocturnal cough. CONCLUSION: Dampness, redecoration and ETS at home, as well as poor ventilation flow, and high RH and PM10 concentration at school may influence respiratory health.
引用
收藏
页码:1187 / +
页数:8
相关论文
共 31 条
[1]  
American Society for Heating Refrigerating and Air Conditioning Engineers, 1999, VENT ACC IND AIR QUA
[2]   Poor air quality in classrooms related to asthma and rhinitis in primary schoolchildren of the French 6 Cities Study [J].
Annesi-Maesano, Isabella ;
Hulin, Marion ;
Lavaud, Francois ;
Raherison, Chantal ;
Kopferschmitt, Christine ;
de Blay, Frederic ;
Charpin, Denis Andre ;
Denis, Caillaud .
THORAX, 2012, 67 (08) :682-688
[3]  
[Anonymous], 2005, WHO AIR QUALITY GUID
[4]   The Health Effects of Passive Smoking: An Overview of Systematic Reviews Based on Observational Epidemiological Evidence [J].
Cao, Shiyi ;
Yang, Chen ;
Gan, Yong ;
Lu, Zuxun .
PLOS ONE, 2015, 10 (10)
[5]  
de Marco R, 1998, EUR RESPIR J, V11, P599
[6]   Home Renovation, Family History of Atopy, and Respiratory Symptoms and Asthma Among Children Living in China [J].
Dong, Guang-Hui ;
Qian, Zhengmin ;
Wang, Jing ;
Trevathan, Edwin ;
Liu, Miao-Miao ;
Wang, Da ;
Ren, Wan-Hui ;
Chen, Weiqing ;
Simckes, Maayan ;
Zelicoff, Alan .
AMERICAN JOURNAL OF PUBLIC HEALTH, 2014, 104 (10) :1920-1927
[7]  
Fraga S, 2008, REV PORT PNEUMOL, V14, P487
[8]   The relative importance of socio-economic status, parental smoking and air pollution (SO2) on asthma symptoms, spirometry and bronchodilator response in 11-year-old children [J].
García-Marcos, L ;
Guillén, JJ ;
Dinwiddie, R ;
Guillén, A ;
Barbero, P .
PEDIATRIC ALLERGY AND IMMUNOLOGY, 1999, 10 (02) :96-100
[9]   Influence of indoor factors in dwellings on the development of childhood asthma [J].
Heinrich, Joachim .
INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2011, 214 (01) :3-27
[10]  
Heseltine E., 2009, WHO GUID IND AIR QUA