A Dedicated Fracture Reduction Room: A Cost-Effective Alternative to the Operating Room

被引:2
|
作者
Whitlock, Patrick W. [1 ]
Little, Kevin J. [1 ]
Singleton, Sandra S. [1 ]
Mahmoud, Mohamed [2 ]
Ngamprasertwong, Pornswan [2 ]
McCarthy, James J. [1 ]
机构
[1] Cincinnati Childrens Hosp Med Ctr, Div Orthopaed Surg, Cincinnati, OH 45229 USA
[2] Cincinnati Childrens Hosp Med Ctr, Dept Anesthesiol, Cincinnati, OH 45229 USA
关键词
PRIVATE INSURANCE; PRACTICE PATTERNS; ORTHOPEDIC CARE; CHILDREN; ACCESS; MEDICAID;
D O I
10.5435/JAAOS-D-17-00800
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Charges, procedural efficiency, return to activity, and complications after closed treatment of fractures performed in an operating room (OR) versus closed reduction in a dedicated fracture reduction room (FRR) were compared. Methods: Patients with closed fractures of the forearm who underwent closed reduction in the year before (OR), and after implementation of the FRR, were retrospectively reviewed. Charges, American Society of Anesthesiologists class, sex, age, length of follow-up, prior reduction, fracture location/displacement, time from injury to procedure, procedural time, time to return to activity, and complications were recorded. Results: Eighteen patients met the inclusion criteria in the FRR group (13 men, 5 women), and 22 in the OR group (18 men, 4 women). No notable differences in age, sex, follow-up, American Society of Anesthesiologists class, fracture location/displacement, incidence of prior reduction, or time to return to activity were observed. Two (9.5%) complications occurred in the FRR group versus 7 (32%) in the OR group, P > 0.05. No anesthesia complications were present. Patients treated in the FRR incurred charges of $5,299 +/- $1,289 versus $10,455 +/- $2,290 in the OR, P < 0.001. Total time of visit in the FRR was similar to 30% less than the OR, P < 0.001. No notable delay in treatment was observed. Discussion: In the era of finite resources and value-based care, implementation of a FRR resulted in safe, cost-effective, and increased procedural efficiency.
引用
收藏
页码:E887 / E892
页数:6
相关论文
共 50 条
  • [21] An Effective Behavioral Nudge in the Operating Room
    Khandelwal, Nita
    Sullivan, Sean D.
    ANESTHESIOLOGY, 2020, 132 (05) : 942 - 943
  • [22] EFFECTIVE TEACHING IN THE OPERATING-ROOM
    SMOOT, EC
    DAROSA, D
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1993, 92 (01) : 133 - 135
  • [23] Use of a Dedicated Operating Room to Reduce Cesarean Delays
    Wheeler, Melissa
    McKinney, Melissa
    Anca, Raluca
    O'Hanlon, Briana
    Follett, Doreen
    Hicks, Jamie
    JOGNN-JOURNAL OF OBSTETRIC GYNECOLOGIC AND NEONATAL NURSING, 2023, 52 (04): : S41 - S41
  • [24] The value of the dedicated orthopaedic trauma operating room - Comment
    Lindsey, RW
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 60 (06): : 1340 - 1341
  • [25] A DEDICATED CT SYSTEM FOR THE STEREOTACTIC OPERATING-ROOM
    LUNSFORD, LD
    APPLIED NEUROPHYSIOLOGY, 1982, 45 (4-5) : 374 - 378
  • [26] Clinical Impact of a Dedicated Trauma Hybrid Operating Room
    Loftus, Tyler J.
    Croft, Chasen A.
    Rosenthal, Martin D.
    Mohr, Alicia M.
    Efron, Philip A.
    Moore, Frederick A.
    Upchurch, Gilbert R., Jr.
    Smith, R. Stephen
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2021, 232 (04) : 560 - 570
  • [27] Value of a Dedicated Saturday Orthopaedic Trauma Operating Room
    Runner, Robert
    Moore, Thomas, Jr.
    Reisman, William
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2016, 30 (01) : E24 - E29
  • [28] COST-EFFECTIVE DRAINAGE ALTERNATIVE
    不详
    PUBLIC WORKS, 1984, 115 (08): : 94 - 94
  • [29] Water fracture provide cost-effective well-stimulation alternative
    Mathis, SP
    Brierley, G
    Sickles, K
    Nelson, D
    Thorness, R
    JOURNAL OF PETROLEUM TECHNOLOGY, 2001, 53 (03): : 39 - 41
  • [30] A CMOS-compatible and cost-effective room temperature sensitive hydrogen sensor
    Mao, Feilong
    Gui, Jiashu
    Zhu, Yifan
    Zeng, Haohan
    Zhang, Hui
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 418