Development of microfluidic platform capable of high-throughput absolute quantification of single-cell multiple intracellular proteins from tumor cell lines and patient tumor samples

被引:20
|
作者
Liu, Lixing [1 ,2 ]
Yang, Hongyu [1 ,3 ]
Men, Dong [4 ]
Wang, Meng [5 ]
Gao, Xiaolei [5 ]
Zhang, Ting [1 ,3 ]
Chen, Deyong [1 ,2 ,3 ]
Xue, Chunlai [6 ]
Wang, Yixiang [5 ]
Wang, Junbo [1 ,2 ,3 ]
Chen, Jian [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, Aerosp Informat Res Inst, State Key Lab Transducer Technol, Beijing, Peoples R China
[2] Univ Chinese Acad Sci, Sch Elect Elect & Commun Engn, Beijing, Peoples R China
[3] Univ Chinese Acad Sci, Sch Future Technol, Beijing, Peoples R China
[4] Chinese Acad Sci, Wuhan Inst Virol, State Key Lab Virol, Wuhan, Peoples R China
[5] Peking Univ, Sch Stomatol, Beijing, Peoples R China
[6] Chinese Acad Sci, Inst Semicond, Beijing, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Single-cell proteomic analysis; Microfluidics; Constriction microchannel; Absolute quantification; High throughput; QUANTITATIVE FLOW-CYTOMETRY; MASS CYTOMETRY; HOUSEKEEPING PROTEINS; HETEROGENEITY; IMMUNE; CHIP;
D O I
10.1016/j.bios.2020.112097
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Quantification of single-cell proteins plays key roles in cell heterogeneity while due to technical limitations absolute numbers of multiple intracellular proteins from large populations of single cells were still missing, leading to compromised results in cell-type classifications. This paper presents a microfluidic platform capable of high-throughput absolute quantification of single-cell multiple types of intracellular proteins where cells stained with fluorescent labelled antibodies are aspirated into the constriction microchannels with excited fluorescent signals detected and translated into numbers of binding sites of targeted proteins based on calibration curves formed by flushing gradient solutions of fluorescent labelled antibodies directly into constriction microchannels. Based on this approach, single-cell numbers of binding sites of beta-actin, alpha-tubulin and beta-tubulin from tens of thousands of five representative tumor cell lines were first quantified, reporting cell-type classification rates of 83.0 +/- 7.1%. Then single-cell numbers of binding sites of beta-actin, biotin and RhoA from thousands of five tumor cell lines with varieties in malignant levels were quantified, reporting cell-type classification rates of 93.7. 2.8%. Furthermore, single-cell numbers of binding sites of Ras, c-Myc and p53 from thousands of cells derived from two oral tumor lines of CAL 27, WSU-HN6 and two oral tumor patient samples were quantified, contributing to high classifications of both tumor cell lines (98.6%) and tumor patient samples (83.4%). In conclusion, the developed microfluidic platform was capable of quantifying multiple intracellular proteins from large populations of single cells, and the collected data of protein expressions enabled effective cell-type classifications.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Development of microfluidic platform to high-throughput quantify single-cell intrinsic bioelectrical markers of tumor cell lines, subtypes and patient tumor cells
    Zhang, Yi
    Liang, Hongyan
    Tan, Huiwen
    Chen, Deyong
    Wang, Yixiang
    Xu, Ying
    Wang, Junbo
    Chen, Jian
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 317
  • [2] A high-throughput microfluidic single-cell screening platform capable of selective cell extraction
    Kim, Hyun Soo
    Devarenne, Timothy P.
    Han, Arum
    LAB ON A CHIP, 2015, 15 (11) : 2467 - 2475
  • [3] Development of a Microfluidic Platform for High-Throughput Characterization of Multiple Biophysical Properties of Single-Cell Membranes
    Yu, Hongfei
    Chen, Xiao
    Zhang, Yi
    Yang, Shuhao
    Gui, Lili
    Chen, Deyong
    Wang, Junbo
    Chen, Jian
    Wang, Ke
    2023 IEEE SENSORS, 2023,
  • [4] A Microfluidic Platform for High-throughput Single-cell Isolation and Culture
    Lin, Ching-Hui
    Chang, Hao-Chen
    Hsu, Chia-Hsien
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2016, (112):
  • [5] A microfluidic flow cytometer enabling absolute quantification of single-cell intracellular proteins
    Li, Xiufeng
    Fan, Beiyuan
    Cao, Shanshan
    Chen, Deyong
    Zhao, Xiaoting
    Men, Dong
    Yue, Wentao
    Wang, Junbo
    Chen, Jian
    LAB ON A CHIP, 2017, 17 (18) : 3129 - 3137
  • [6] HIGH-THROUGHPUT SINGLE-CELL PATHOGEN DETECTION ON A DROPLET MICROFLUIDIC PLATFORM
    Rane, Tushar D.
    Zec, Helena
    Puleo, Chris
    Lee, Abraham P.
    Wang, Tza-Huei
    2011 IEEE 24TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2011, : 881 - 884
  • [7] Creation of a High-Throughput Microfluidic Platform for Single-Cell Transcriptome Sequencing of Cell-Cell Interactions
    Qi, Jingyu
    Zhu, Haibin
    Li, Yijian
    Guan, Xiangyu
    He, Ying
    Ren, Guanhua
    Guo, Qiang
    Liu, Longqi
    Gu, Ying
    Dong, Xuan
    Liu, Ya
    SMALL METHODS, 2023, 7 (11)
  • [8] High-Throughput, Living Single-Cell, Multiple Secreted Biomarker Profiling Using Microfluidic Chip and Machine Learning for Tumor Cell Classification
    Wang, Chao
    Wang, Chunhua
    Wu, Yu
    Gao, Jianwei
    Han, Yingkuan
    Chu, Yujin
    Qiang, Le
    Qiu, Jiaoyan
    Gao, Yakun
    Wang, Yanhao
    Song, Fangteng
    Wang, Yihe
    Shao, Xiaowei
    Zhang, Yu
    Han, Lin
    ADVANCED HEALTHCARE MATERIALS, 2022, 11 (13)
  • [9] Development of Microfluidic Systems Enabling High-Throughput Single-Cell Protein Characterization
    Fan, Beiyuan
    Li, Xiufeng
    Chen, Deyong
    Peng, Hongshang
    Wang, Junbo
    Chen, Jian
    SENSORS, 2016, 16 (02):
  • [10] Droplet microfluidic technology for single-cell high-throughput screening
    Brouzes, Eric
    Medkova, Martina
    Savenelli, Neal
    Marran, Dave
    Twardowski, Mariusz
    Hutchison, J. Brian
    Rothberg, Jonathan M.
    Link, Darren R.
    Perrimon, Norbert
    Samuels, Michael L.
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2009, 106 (34) : 14195 - 14200