Automated keratometry in routine cataract surgery: Comparison of Scheimpflug and conventional values

被引:40
作者
Symes, Richard J. [1 ]
Ursell, Paul G. [1 ]
机构
[1] Epsom & St Helier Univ Hosp NHS Trust, London, England
关键词
CORNEAL POWER MEASUREMENTS; PARTIAL COHERENCE INTERFEROMETRY; ANTERIOR-CHAMBER DEPTH; REFRACTIVE SURGERY; PENTACAM; EYES; PHOTOGRAPHY; ACCURACY; BIOMETRY; REPRODUCIBILITY;
D O I
10.1016/j.jcrs.2010.08.050
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the mean keratometry (K) readings obtained with a conventional automated keratometer (IOLMaster) and a Scheimpflug keratometer (Pentacam) in eyes having preoperative assessment for routine cataract surgery. SETTING: Epsom and St. Helier University Hospitals, London, United Kingdom. DESIGN: Evaluation of diagnostic technology. METHODS: Mean K values were obtained with the conventional and Scheimpflug keratometers. The following Scheimpflug readings were evaluated: anterior K, true net power, and Holladay equivalent K measured at 1.0 to 7.0 mm corneal diameters. Mean readings for each type of keratometry were compared. Bland-Altman plots were used to determine the 95% limits of agreement (LoA) for the conventional and Scheimpflug keratometers. RESULTS: The mean conventional K was statistically significantly greater than the mean Scheimpflug K for true net power and equivalent K at 1.0 mm, 2.0 mm, 3.0 mm, and 4.0 mm corneal diameters. The mean conventional K was significantly less than the equivalent K at 5.0 mm, 6.0 mm, and 7.0 mm. The smallest mean difference was for equivalent K at 4.5 mm (0.02 diopters [D]). The smallest 95% LoA were -0.68 to 1.16 D (equivalent K at 5.0 mm) and -0.91 to 0.95 D (equivalent K at 4.5 mm). CONCLUSIONS: Overall, the equivalent K at 4.5 mm had the closest match with the conventional K values. The degree of interdevice variability with the conventional keratometer was lowest for the equivalent K at 4.5 mm and 5.0 mm, although this variability would be sufficient to influence intraocular lens power selection.
引用
收藏
页码:295 / 301
页数:7
相关论文
共 23 条
  • [1] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [2] Pentacam keratometry and IOL power calculation - Reply
    Borasio, Edmondo
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (01) : 4 - 4
  • [3] Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula
    Borasio, Edmondo
    Stevens, Julian
    Smith, Guy T.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (12) : 2004 - 2014
  • [4] Comparison of different techniques of anterior chamber depth and keratometric measurements
    Elbaz, Uri
    Barkana, Yaniv
    Gerber, Yariv
    Avni, Isaac
    Zadok, David
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (01) : 48 - 53
  • [5] Corneal Power Measurements Using Scheimpflug Imaging in Eyes With Prior Corneal Refractive Surgery
    Holladay, Jack T.
    Hill, Warren E.
    Steinmueller, Andreas
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (10) : 862 - 868
  • [6] HOLLADAY JT, 2006, WHY CATARACT REFRACT, P4
  • [7] Repeatability, reproducibility, and agreement characteristics of rotating Scheimpflug photography and scanning-slit corneal topography for corneal power measurement
    Kawamorita, Takushi
    Uozato, Hiroshi
    Kamiya, Kazutaka
    Bax, Leon
    Tsutsui, Kenta
    Aizawa, Daisuke
    Shimizu, Kimiya
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (01) : 127 - 133
  • [8] Use of the Pentacam True Net Corneal Power for Intraocular Lens Calculation in Eyes After Refractive Corneal Surgery
    Kim, Sang Woo
    Kim, Eung Kweon
    Cho, Beom-Jin
    Kim, Sun Woong
    Song, Ki Yung
    Kim, Tae-im
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (03) : 285 - 289
  • [9] Pentacam keratometry and IOL power calculation
    Norrby, Sverker
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (01) : 3 - 3
  • [10] Improved accuracy of intraocular lens power calculation with the Zeiss IOLMaster
    Olsen, Thomas
    [J]. ACTA OPHTHALMOLOGICA SCANDINAVICA, 2007, 85 (01): : 84 - 87