Influence of decontamination procedures on shear forces after contamination with blood or saliva

被引:15
作者
Brauchli, Lorenz [1 ]
Eichenberger, Martina [1 ]
Steineck, Markus [1 ]
Wichelhaus, Andrea [1 ]
机构
[1] Univ Basel, Clin Orthodont & Pedodont, CH-4056 Basel, Switzerland
关键词
MODIFIED GLASS-IONOMER; SELF-ETCHING PRIMERS; RESIN BOND STRENGTH; IN-VITRO; ORTHODONTIC BRACKETS; ETCHED ENAMEL; ADHESIVE; MOISTURE; CEMENT; COMPOSITE;
D O I
10.1016/j.ajodo.2008.10.021
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Despite rapid development in adhesive technology, contamination of bonding surfaces remains a major problem. The aims of this study were to evaluate the influence of contamination on bond strength and to investigate possible decontamination procedures. Methods: Four bonding systems were evaluated for their shear bond strengths under 5 bonding situations: control (without contamination and decontamination); contamination with blood; contamination with saliva; decontamination with water and air, and repriming after blood contamination; and decontamination with water and air, and repriming after saliva contamination. The 25 specimens of each group consisted of composite blocks bonded to bovine teeth. Shear forces were measured with a testing machine after thermocycling. Results: The 3 composite primers showed similar behavior. With the exception of Transbond SEP (3M Unitek, Monrovia, Calif) with saliva contamination, all contaminated samples showed greatly reduced shear forces. The control and decontaminated groups showed shear forces about 20 MPa. The resin-modified glass ionomer, however, did not reach clinically sufficient bond strengths in either setup. Conclusions: Decontamination with water and air and repriming is sufficient after contamination with blood or saliva. Etching again is not necessary. The bond strength of Transbond SEP was not significantly altered by saliva contamination and can be recommended for conventional bonding procedures. (Am J Orthod Dentofacial Orthop 2010;138:435-41)
引用
收藏
页码:435 / 441
页数:7
相关论文
共 39 条
[1]  
Arici S, 2003, ANGLE ORTHOD, V73, P692
[2]  
Bishara SE, 2002, ANGLE ORTHOD, V72, P554
[3]  
Buonocore M.G., 1955, J DENT RES, V34, P849, DOI [DOI 10.1177/00220345550340060801, 10.1177/00220345550340060801]
[4]  
Burgess AM, 2006, ANGLE ORTHOD, V76, P114
[5]   Effect of blood contamination on shear bond strength of brackets bonded with a self-etching primer combined with a resin-modified glass ionomer [J].
Cacciafesta, V ;
Sfondrini, MF ;
Scribante, A ;
De Angelis, M ;
Klersy, C .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2004, 126 (06) :703-708
[6]   Effects of blood contamination on the shear bond strengths of conventional and hydrophilic primers [J].
Cacciafesta, V ;
Sfondrini, MF ;
Scribante, A ;
De Angelis, M ;
Klersy, C .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2004, 126 (02) :207-212
[7]  
Cal-Neto JP, 2006, ANGLE ORTHOD, V76, P127
[8]  
Coups-Smith KS, 2003, ANGLE ORTHOD, V73, P436
[9]   Effects of blood contamination on resin-resin bond strength [J].
Eiriksson, SO ;
Pereira, PNR ;
Swift, EJ ;
Heymann, HO ;
Sigurdsson, A .
DENTAL MATERIALS, 2004, 20 (02) :184-190
[10]   Effects of saliva contamination on resin-resin bond strength [J].
Eiriksson, SO ;
Pereira, PNR ;
Swift, EJ ;
Heymann, HO ;
Sigurdsson, A .
DENTAL MATERIALS, 2004, 20 (01) :37-44