Poor ventilation worsens short-range airborne transmission of respiratory infection

被引:75
作者
Li, Yuguo [1 ]
Cheng, Pan [1 ]
Jia, Wei [1 ]
机构
[1] Univ Hong Kong, Dept Mech Engn, Pokfulam Rd, Hong Kong, Peoples R China
关键词
close contact; expired jet; long-range airborne transmission; respiratory infection; SARS-CoV-2; short-range airborne transmission; ventilation; EXPIRATORY DROPLETS; REQUIREMENTS; SPREAD; ODOR; RISK;
D O I
10.1111/ina.12946
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To explain the observed phenomenon that most SARS-CoV-2 transmission occurs indoors whereas its outdoor transmission is rare, a simple macroscopic aerosol balance model is developed to link short- and long-range airborne transmission. The model considers the involvement of exhaled droplets with initial diameter <= 50 mu m in the short-range airborne route, whereas only a fraction of these droplets with an initial diameter within 15 mu m or equivalently a final diameter within 5 mu m considered in the long-range airborne route. One surprising finding is that the room ventilation rate significantly affects the short-range airborne route, in contrast to traditional belief. When the ventilation rate in a room is insufficient, the airborne infection risks due to both short- and long-range transmission are high. A ventilation rate of 10 L/s per person provides a similar concentration vs distance decay profile to that in outdoor settings, which provides additional justification for the widely adopted ventilation standard of 10 L/s per person. The newly obtained data do not support the basic assumption in the existing ventilation standard ASHRAE 62.1 (2019) that the required people outdoor air rate is constant if the standard is used directly for respiratory infection control. Instead, it is necessary to increase the ventilation rate when the physical distance between people is less than approximately 2 m.
引用
收藏
页数:10
相关论文
共 23 条
[21]   The impact of retrofitted ventilation approaches on long-range airborne infection risk for lecture room environments: design stage methodology and application [J].
O'Donovan, Adam ;
O'Sulhvan, Paul D. .
JOURNAL OF BUILDING ENGINEERING, 2023, 68
[22]   Effect of ventilation and climatic conditions on COVID-19 transmission through respiratory droplet transport via both airborne and fomite mode inside an elevator [J].
Pal, Anish ;
Biswas, Riddhideep ;
Sarkar, Sourav ;
Mukhopadhyay, Achintya .
PHYSICS OF FLUIDS, 2022, 34 (08)
[23]   High-resolution large-eddy simulation of indoor turbulence and its effect on airborne transmission of respiratory pathogens-Model validation and infection probability analysis [J].
Auvinen, Mikko ;
Kuula, Joel ;
Gronholm, Tiia ;
Suhring, Matthias ;
Hellsten, Antti .
PHYSICS OF FLUIDS, 2022, 34 (01)