A Field-Portable Membrane Introduction Mass Spectrometer for Real-time Quantitation and Spatial Mapping of Atmospheric and Aqueous Contaminants

被引:36
作者
Bell, Ryan J. [1 ]
Davey, Nicholas G. [1 ,2 ]
Martinsen, Morten [1 ,3 ]
Collin-Hansen, Christian [4 ]
Krogh, Erik T. [1 ,2 ]
Gill, Christopher G. [1 ,2 ]
机构
[1] Vancouver Isl Univ, Dept Chem, AERL, Nanaimo, BC, Canada
[2] Univ Victoria, Dept Chem, Victoria, BC, Canada
[3] Norwegian Univ Sci & Technol NTNU, Dept Chem, Trondheim, Norway
[4] Statoil Petr ASA, TPD RDI Frontier Dev, Trondheim, Norway
关键词
VOC/SVOC; Membrane introduction mass spectrometry (MIMS); Emissions; Alberta oil sands; Mobile mass spectrometry; Real time quantitative mapping; VOLATILE ORGANIC-COMPOUNDS; ONLINE MEASUREMENT; COMPOUNDS VOCS; WATER; AIR; MS; POLLUTANTS; EMISSIONS; GASES;
D O I
10.1007/s13361-014-1028-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Environmental concentrations of volatile and semivolatile organic compounds (VOC/SVOCs) can vary dramatically in time and space under the influence of environmental conditions. In an industrial setting, multiple point and diffuse sources can contribute to fugitive emissions. Assessments and monitoring programs using periodic grab sampling provide limited information, often with delay times of days or weeks. We report the development and use of a novel, portable membrane introduction mass spectrometry (MIMS) system capable of resolving and quantifying VOC and SVOCs with high spatial and temporal resolution, in the field, in real-time. An electron impact ionization cylindrical ion trap mass spectrometer modified with a capillary hollow fiber polydimethylsiloxane membrane interface was used for continuous air and water sampling. Tandem mass spectrometry and selected ion monitoring scans performed in series allowed for the quantitation of target analytes, and full scan mode was used to survey for unexpected analytes. Predeployment and in-field external calibrations were combined with a continuously infused internal standard to enable real-time quantitation and monitor instrument performance. The system was operated in a moving vehicle with internet-linked data processing and storage. Software development to integrate MIMS and relevant meta-data for visualization and geospatial presentation in Google Earth is presented. Continuous quantitation enables the capture of transient events that may be missed or under-represented by traditional grab sampling strategies. Real-time geospatial maps of chemical concentration enable adaptive sampling and in-field decision support. Sample datasets presented in this work were collected in Northern Alberta in 2010-2012.
引用
收藏
页码:212 / 223
页数:12
相关论文
共 39 条
  • [1] [Anonymous], ASS ENV IMPL OIL GAS
  • [2] Oil-in-Water Monitoring Using Membrane Inlet Mass Spectrometry
    Brkic, Boris
    France, Neil
    Taylor, Stephen
    [J]. ANALYTICAL CHEMISTRY, 2011, 83 (16) : 6230 - 6236
  • [3] Tracking Hydrocarbon Plume Transport and Biodegradation at Deepwater Horizon
    Camilli, Richard
    Reddy, Christopher M.
    Yoerger, Dana R.
    Van Mooy, Benjamin A. S.
    Jakuba, Michael V.
    Kinsey, James C.
    McIntyre, Cameron P.
    Sylva, Sean P.
    Maloney, James V.
    [J]. SCIENCE, 2010, 330 (6001) : 201 - 204
  • [4] Characterizing Spatial and Temporal Variability of Dissolved Gases in Aquatic Environments with in situ Mass Spectrometry
    Camilli, Richard
    Duryea, Anthony N.
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2009, 43 (13) : 5014 - 5021
  • [5] Direct measurement of fugitive emissions of hydrocarbons from a refinery
    Chambers, Allan K.
    Strosher, Melvin
    Wootton, Tony
    Moncrieff, Jan
    McCready, Philip
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2008, 58 (08) : 1047 - 1056
  • [6] Analysis of Semivolatile Pharmaceuticals and Pollutants in Organic Micro Extracts Using Hot Cell Membrane Inlet Mass Spectrometry
    Chen, Hua
    Xia, Zhining
    Pedersen-Bjergaard, Stig
    Svensmark, Bo
    Lauritsen, Frants R.
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (10) : 4010 - 4014
  • [7] Cooks R Graham, 2013, Mass Spectrom (Tokyo), V2, pS0001, DOI 10.5702/massspectrometry.S0001
  • [8] Measurement of spatial and temporal variation in volatile hazardous air pollutants in Tacoma, Washington, using a mobile membrane introduction mass spectrometry (MIMS) system
    Davey, Nicholas G.
    Fitzpatrick, Cole T. E.
    Etzkorn, Jacob M.
    Martinsen, Morten
    Crampton, Robert S.
    Onstad, Gretchen D.
    Larson, Timothy V.
    Yost, Michael G.
    Krogh, Erik T.
    Gilroy, Michael
    Himes, Kathy H.
    Saganic, Erik T.
    Simpson, Christopher D.
    Gill, Christopher G.
    [J]. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2014, 49 (11): : 1199 - 1208
  • [9] Membrane-introduction mass spectrometry (MIMS)
    Davey, Nicholas G.
    Krogh, Erik T.
    Gill, Chris G.
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2011, 30 (09) : 1477 - 1485
  • [10] The Use of MIMS-MS-MS in Field Locations as an On-Line Quantitative Environmental Monitoring Technique for Trace Contaminants in Air and Water
    Etzkorn, J. M.
    Davey, N. G.
    Thompson, A. J.
    Creba, A. S.
    LeBlanc, C. W.
    Simpson, C. D.
    Krogh, E. T.
    Gill, C. G.
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2009, 47 (01) : 57 - 66