Influence of Screw Surface Treatment on Retention of Implant-Supported Fixed Partial Dentures

被引:11
作者
de Moura, Marcos Boaventura [1 ]
Rodrigues, Renata Borges [2 ]
Pinto, Leandro Moreira [1 ]
de Araujo, Cleudmar Amaral [3 ]
Novais, Veridiana Resende [2 ]
Simamoto Junior, Paulo Cezar [1 ]
机构
[1] Univ Fed Uberlandia, Sch Dent, Dept Occlus Fixed Prosthodont & Dent Mat, Uberlandia, MG, Brazil
[2] Univ Fed Uberlandia, Dent Sch, Dept Operat Dent & Dent Mat, Uberlandia, MG, Brazil
[3] Univ Fed Uberlandia, Mech Sch, Mech Projects Lab Henner A Gomide, Uberlandia, MG, Brazil
关键词
dental implants; implant prosthesis; implant screw; mechanical cycling; splinting; FINITE-ELEMENT-ANALYSIS; ABUTMENT SCREW; INTERPROXIMAL CONTACT; PROSTHETIC SCREWS; DENTAL IMPLANTS; TORQUE; PRELOAD; BONE; COMPLICATIONS; RESTORATIONS;
D O I
10.1563/aaid-joi-D-16-00145
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to assess the effect of a diamond-like carbon (DLC) coating on the removal torque of prefabricated implant screws after cyclic loading. Four groups with two crowns supported by two implants (n = 5) were obtained according to splinted and nonsplinted prosthesis, using titanium or DLC screws (splinted crowns with titanium screw [STi], splinted crowns with DLC screw [SC], nonsplinted crowns and titanium screw [NSTi], and nonsplinted crowns and DLC screw [NSC]). The prosthetic screws were tightened at 32 Ncm and retightened, and the specimens were submitted to 106 mechanical cycles (4 Hz/98 N). After cyclic loading, loosening torque was evaluated, and the final measurements were performed. Data were analyzed by two-way analysis of variance and Tukey's test (alpha = .005). There was statistically significance in the interaction of screw X splinting (P = .003). For the group that used titanium screws, NSTi showed smaller removal torque compared with STi. It was concluded that the use of the DLC coating screws in nonsplinted prosthesis maintain the torque after cyclic loading.
引用
收藏
页码:254 / 260
页数:7
相关论文
共 50 条
  • [21] Clinical outcomes of implant-supported monolithic zirconia crowns and fixed partial dentures: A systematic review
    Kim, Wanjin
    Li, Xiao Chun
    Bidra, Avinash S.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (02): : 102 - 107
  • [22] Changes in masticatory laterality 3 months after treatment with unilateral implant-supported fixed partial prosthesis
    Khoury-Ribas, Laura
    Ayuso-Montero, Raul
    Willaert, Eva
    Peraire, Maria
    Martinez-Gomis, Jordi
    JOURNAL OF ORAL REHABILITATION, 2020, 47 (01) : 78 - 85
  • [23] Influence of Mechanical Cycling on Torque Values of Tapped-In and Screw-In Implant-Supported Crowns
    Ferreira, Rodrigo M.
    Prado, Abraao M.
    Oliveira, Matheus S.
    Tonin, Racchel E.
    Mori, Aline A.
    Ferruzzi, Fernanda
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2023, 31 (02) : 104 - 108
  • [24] Clinical success of implant-supported and tooth–implant-supported double crown-retained dentures
    Gunda Bernhart
    Andreas Koob
    Marc Schmitter
    Olaf Gabbert
    Thomas Stober
    Peter Rammelsberg
    Clinical Oral Investigations, 2012, 16 : 1031 - 1037
  • [25] The impact of cantilevers on biological and technical success outcomes of implant-supported fixed partial dentures. A retrospective cohort study
    Kim, Paul
    Ivanovski, Saso
    Latcham, Neil
    Mattheos, Nikos
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (02) : 175 - 184
  • [26] Influence of Prosthetic Screw Material on Joint Stability in Passive and Non-Passive Implant-Supported Dentures
    Spazzin, Aloisio Oro
    Pessanha Henriques, Guilherme Elias
    de Arruda Nobilo, Mauro Antonio
    Xediek Consani, Rafael Leonardo
    Correr-Sobrinho, Lourenco
    Mesquita, Marcelo Ferraz
    OPEN DENTISTRY JOURNAL, 2009, 3 : 245 - 249
  • [27] Trauma to an implant-supported crown that was saved by the fixation screw: a case report
    den Hartog, Laurens
    Meijer, Henny J. A.
    Stellingsma, Kees
    Santing, Hendrik J.
    Raghoebar, Gerry M.
    DENTAL TRAUMATOLOGY, 2010, 26 (04) : 366 - 369
  • [28] Comparison of the Effect of Implant Abutment Surface Modifications on the Retention of Implant-Supported Restorations
    Khan, Mohammed Aatif Abid
    Godil, Aamir Zahid
    Wadwan, Sanaa Akhlaq
    Kheur, Mohit Gurunath
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2024, 39 (02) : 278 - 285
  • [29] The Influence of Connection on the Microleakage Development of Implant-Supported Fixed Bridges
    von Maltzahn, Nadine Freifrau
    Altmayer, Niels
    Kommerein, Nadine
    Stiesch, Meike
    Kohorst, Philipp
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2021, 29 (02) : 112 - 118
  • [30] The Role of Implant/Abutment System on Torque Maintenance of Retention Screws and Vertical Misfit of Implant-Supported Crowns Before and After Mechanical Cycling
    Pala Jorge, Juliana Ribeiro
    Ricardo Barao, Valentim Adelino
    Delben, Juliana Aparecida
    Assuncao, Wirley Goncalves
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (02) : 415 - 422