Assessment of exhaled nitric oxide by a new hand-held device

被引:38
作者
Antus, Balazs [1 ]
Horvath, Ildiko [2 ]
Barta, Imre [1 ]
机构
[1] Natl Koranyi Inst TB & Pulmonol, Dept Pathophysiol, H-1529 Budapest, Hungary
[2] Semmelweis Univ, Dept Pulmonol, H-1125 Budapest, Hungary
关键词
Exhaled nitric oxide; Logan; NIOX MINO; NObreath; Reproducibility; ASTHMA; ANALYZER;
D O I
10.1016/j.rmed.2010.06.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Fractional exhaled nitric oxide (FENO) has been implicated as a pulmonary biomarker. The aim of this study was to compare the performance of a new hand-held device to a standard chemiluminescence analyzer and to another portable device. Methods: FENO levels measured by NObreath (Bedfont) were compared to those of (1) a chemiluminescence detector (Logan, Logan Research) and (2) the electrochemical portable NIOX MINO (Aerocrine) in 18 healthy volunteers on three consecutive occasions: in the morning, 1 h and 24 h later. Results: Comparing FENO levels obtained by NObreath to those by Logan values were similar and a very close linear relationship was found between the two devices (r = 0.923, p < 0.001). The mean inter-device difference in FENO level was -3.45 ppb and the limits of agreement (Bland-Altman test) were -10.98 and 4.08 ppb. In the second series FENO levels obtained by NObreath were found to be slightly higher compared to those of NIOX MINO, but still showed a close correlation (r = 0.681, p < 0.001). The mean inter-device difference in FENO level was 4.36 ppb and the limits of agreement were -7.38 and 16.1 ppb. Analyzing the repeated FENO measurements, the mean coefficient of variation using NObreath tended to be lower than that of NIOX MINO (16.9 vs. 24.7%, p = 0.059), while it was similar as the value obtained with Logan (11.8 vs. 9.0%, p = 0.342). Conclusions: FENO values measured with NObreath are reproducible and in good agreement with those obtained by NIOX MINO and Logan indicating that NObreath is suitable for use in clinical practice. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1377 / 1380
页数:4
相关论文
共 14 条
  • [1] Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children
    Alving, K
    Janson, C
    Nordvall, L
    [J]. RESPIRATORY RESEARCH, 2006, 7 (1)
  • [2] [Anonymous], AM J RESP CRIT CARE
  • [3] Comparison of exhaled nitric oxide measurements between NIOX MINO® electrochemical and Ecomedics chemiluminescence analyzer
    Boot, J. D.
    de Ridder, L.
    de Kam, M. L.
    Calderon, C.
    Mascelli, M. A.
    Diamant, Z.
    [J]. RESPIRATORY MEDICINE, 2008, 102 (11) : 1667 - 1671
  • [4] Novel hand-held device for exhaled nitric oxide-analysis in research and clinical applications
    Hemmingsson T.
    Linnarsson D.
    Gambert R.
    [J]. Journal of Clinical Monitoring and Computing, 2004, 18 (5-6) : 379 - 387
  • [5] Reliability of a new hand-held device for the measurement of exhaled nitric oxide
    Khalili, B.
    Boggs, P. B.
    Bahna, S. L.
    [J]. ALLERGY, 2007, 62 (10) : 1171 - 1174
  • [6] Exhaled biomarkers
    Kharitonov, Sergei A.
    Barnes, Peter J.
    [J]. CHEST, 2006, 130 (05) : 1541 - 1546
  • [7] Portable exhaled nitric oxide measurement - Comparison with the "gold standard" technique
    Menzies, Daniel
    Nair, Arun
    Lipworth, Brian J.
    [J]. CHEST, 2007, 131 (02) : 410 - 414
  • [8] The use of exhaled nitric oxide in the management of asthma
    Pavord, Ian D.
    Shaw, Dominic
    [J]. JOURNAL OF ASTHMA, 2008, 45 (07) : 523 - 531
  • [9] Exhaled nitric oxide in childhood asthma: a review
    Pijnenburg, M. W. H.
    De Jongste, J. C.
    [J]. CLINICAL AND EXPERIMENTAL ALLERGY, 2008, 38 (02) : 246 - 259
  • [10] Exhaled nitric oxide measurements: Correction equation to compare hand-held device to stationary analyzer
    Pizzimenti, Stefano
    Bugiani, Massimiliano
    Piccioni, Pavilio
    Heffler, Enrico
    Carosso, Aurelia
    Guida, Giuseppe
    Rolla, Giovanni
    [J]. RESPIRATORY MEDICINE, 2008, 102 (09) : 1272 - 1275