共 50 条
Reassessment of 182Hf AMS measurements at VERA
被引:12
|作者:
Forstner, O.
[1
]
Gnaser, H.
[2
]
Golser, R.
[1
]
Hanstorp, D.
[3
]
Martschini, M.
[1
]
Priller, A.
[1
]
Rohlen, J.
[3
]
Steier, P.
[1
]
Vockenhuber, C.
[4
]
Wallner, A.
[1
]
机构:
[1] Univ Vienna, Fak Phys Isotopenforsch, A-1090 Vienna, Austria
[2] Tech Univ Kaiserslautern, Fachbereich Phys, D-67663 Kaiserslautern, Germany
[3] Univ Gothenburg, Dept Phys, SE-41296 Gothenburg, Sweden
[4] ETH, Inst Particle Phys, CH-8033 Zurich, Switzerland
来源:
关键词:
Hf-182;
AMS;
Sputter ion source;
Negative ion yield;
D O I:
10.1016/j.nimb.2011.04.022
中图分类号:
TH7 [仪器、仪表];
学科分类号:
0804 ;
080401 ;
081102 ;
摘要:
The radioisotope Hf-182 (t(1/2) = 8.9 Ma) is of great interest for astrophysical applications as a chronometer for the early solar system or as possible live supernova remnant on earth. However, AMS measurements of Hf-182 are seriously influenced by the presence of the stable isobar W-182, which cannot be separated at typical AMS energies. Previous studies revealed a possible suppression of W-182 against Hf-182 by extracting the negatively charged pentafluoride HfF5- from the ion source, leading to a detection limit for Hf-182/Hf-180 in the order of 10(-11). However, this suppression behavior is in contrast to theoretical calculations of the electron affinity and recent measurements using SIMS instruments, where the achieved suppression cannot be reproduced. The aim of our study is to determine the effects of ion source background as well as further investigate the suppression of tungsten against hafnium by extracting negatively charged fluoride ions from different sample materials. The previously reported suppression factor of about 6000 could be increased to 36000 by careful tuning of the ion source using HfF4 as sample material. The trend of the theoretical electron affinities could be reproduced using atomic tungsten and hafnium instead of HfF4 as sample material. This supports the assumption that the major contribution of the tungsten background is not sputtered from the target matrix but comes from somewhere else in the ion source. Measurements from the second ion source show a higher background of tungsten and a lower suppression factor, i.e. careful design of the ion source is crucial. Moving the sputter beam over the target surface extending over the wheel holding the targets revealed the highest tungsten background was detected outside the sputter target position. Further investigations are necessary to locate the origin of the tungsten background in the ion source. Possible sources are the material used for the ion source construction or contaminations in the cesium used for sputtering. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:3180 / 3182
页数:3
相关论文