Pulse compression for finite amplitude distortion based harmonic imaging using coded waveforms

被引:0
作者
Li, PC [1 ]
机构
[1] Natl Taiwan Univ, Dept Elect Engn, Taipei 10764, Taiwan
关键词
coded excitation; contrast imaging; finite amplitude distortion; harmonic imaging; ultrasonic imaging;
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Finite amplitude distortion based harmonic imaging has been used to reduce the image quality degradation produced by tissue inhomogeneities. Such harmonic signals are significantly lower than the linear components and are possibly too low compared to the dynamic range of the imaging system. To improve signal-to-noise ratio (SNR) without exceeding regulatory limits, coded excitation is explored. In addition, pulse compression schemes suitable for finite amplitude distortion based harmonic imaging are also developed. Note that due to the differences in harmonic generation, these compression schemes are different from those proposed for harmonic imaging using contrast agents. In this paper, simulation examples of SNR improvements by up to 8.2dB are shown and the efficacy of the compression schemes is studied. Potential sources of performance degradation are also discussed.
引用
收藏
页码:1 / 16
页数:16
相关论文
共 23 条
[1]   NEW APPROACHES TO NONLINEAR DIFFRACTIVE FIELD PROPAGATION [J].
CHRISTOPHER, PT ;
PARKER, KJ .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1991, 90 (01) :488-499
[2]   Experimental investigation of finite amplitude distortion-based, second harmonic pulse echo ultrasonic imaging [J].
Christopher, T .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (01) :158-162
[3]   Finite amplitude distortion-based inhomogeneous pulse echo ultrasonic imaging [J].
Christopher, T .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (01) :125-139
[4]   ABSORPTION AND SCATTER OF ENCAPSULATED GAS FILLED MICROSPHERES - THEORETICAL CONSIDERATIONS AND SOME MEASUREMENTS [J].
DEJONG, N ;
HOFF, L ;
SKOTLAND, T ;
BOM, N .
ULTRASONICS, 1992, 30 (02) :95-103
[5]   HIGHER HARMONICS OF VIBRATING GAS-FILLED MICROSPHERES .2. MEASUREMENTS [J].
DEJONG, N ;
CORNET, R ;
LANCEE, CT .
ULTRASONICS, 1994, 32 (06) :455-459
[6]   HIGHER HARMONICS OF VIBRATING GAS-FILLED MICROSPHERES .1. SIMULATIONS [J].
DEJONG, N ;
CORNET, R ;
LANCEE, CT .
ULTRASONICS, 1994, 32 (06) :447-453
[7]   On the feasibility of real time, in vivo harmonic imaging with proteinaceous microspheres [J].
Forsberg, F ;
Goldberg, BB ;
Liu, JB ;
Merton, DA ;
Rawool, NM .
JOURNAL OF ULTRASOUND IN MEDICINE, 1996, 15 (12) :853-860
[8]   Retrospective dynamic transmit focusing [J].
Freeman, S ;
Li, PC ;
ODonnell, M .
ULTRASONIC IMAGING, 1995, 17 (03) :173-196
[9]   ULTRASOUND CONTRAST AGENTS - A REVIEW [J].
GOLDBERG, BB ;
LIU, JB ;
FORSBERG, F .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (04) :319-333
[10]  
Goodman W., 2005, INTRO FOURIER OPTICS, V3rd