Low-Cost Noninvasive Real-Time Imaging for Tubular Continuous-Flow Crystallization

被引:29
|
作者
Jiang, Mo [1 ]
Braatz, Richard D. [1 ]
机构
[1] MIT, Dept Chem Engn, 77 Massachusetts Ave, Cambridge, MA 02139 USA
关键词
Continuous crystallization; Imaging technology; Inline monitoring; Multiphase flow; Tubular crystallizer; CONTINUOUS MANUFACTURING SYMPOSIUM; PARTICLE-SIZE DISTRIBUTIONS; SHAPE; SPECTROSCOPY; ANTISOLVENT; MICROSCOPY;
D O I
10.1002/ceat.201600276
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A key design limitation to the effective monitoring and control of continuous crystallization processes is the ability to characterize crystals in real time. A low-cost system composed of a basic stereomicroscope and video camera for the in situ imaging of sub-millimeter crystals through curved walls of millifluidic tubular crystallizers is described. Real-time videos taken for millimeter-size slurry slugs are used to guide the experimental design for a recently developed multiphase-flow crystallization process, including the improvement of the slug aspect ratio, visualization of crystal shapes, and observation of the extent of aggregation. Design considerations are also discussed for the use of multiple stereomicroscopes in other continuous-flow tubular experiments.
引用
收藏
页码:143 / 148
页数:6
相关论文
共 50 条
  • [1] Low-cost, real-time, continuous flow PCR system for pathogen detection
    Fernandez-Carballo, B. Leticia
    McGuiness, Ian
    McBeth, Christine
    Kalashnikov, Maxim
    Borros, Salvador
    Sharon, Andre
    Sauer-Budge, Alexis F.
    BIOMEDICAL MICRODEVICES, 2016, 18 (02)
  • [2] Low-cost, real-time, continuous flow PCR system for pathogen detection
    B. Leticia Fernández-Carballo
    Ian McGuiness
    Christine McBeth
    Maxim Kalashnikov
    Salvador Borrós
    Andre Sharon
    Alexis F. Sauer-Budge
    Biomedical Microdevices, 2016, 18
  • [3] LOW-COST REAL-TIME IMAGING AND PROCESSING SYSTEM.
    Li, H.F.
    Tsang, C.M.
    Cheung, Y.S.
    Software & microsystems, 1983, 2 (05): : 121 - 129
  • [4] Low-cost wearable measurement system for continuous real-time pedobarography
    Corbellini, Simone
    Ramella, Chiara
    Fallauto, Carmelo
    Pirola, Marco
    Stassi, Stefano
    Canavese, Giancarlo
    2015 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA) PROCEEDINGS, 2015, : 639 - 644
  • [5] A Low-Cost Digital Microscope with Real-Time Fluorescent Imaging Capability
    Hasan, Md. Mehedi
    Alam, Mohammad Wajih
    Wahid, Khan A.
    Miah, Sayem
    Lukong, Kiven Erique
    PLOS ONE, 2016, 11 (12):
  • [6] Real-time low-cost passive imaging system for automotive applications
    Chamseddine, A
    Klingler, M
    Heddebaut, M
    Bocquet, B
    Rolland, N
    Noirel, P
    Cappy, A
    Rolland, PA
    IEEE VEHICULAR TECHNOLOGY CONFERENCE, FALL 2000, VOLS 1-6, PROCEEDINGS: BRINGING GLOBAL MOBILITY TO THE NETWORK AGE, 2000, : 2033 - 2038
  • [7] LOW-COST, FLEXIBLE MICROCOMPUTER DATA SYSTEM FOR CONTINUOUS-FLOW ANALYSIS
    CHASE, SE
    SANBORN, JR
    RENOE, BW
    CLINICAL CHEMISTRY, 1979, 25 (06) : 1122 - 1122
  • [8] A Practical Design and Implementation of a Low-Cost Platform for Real-Time Diagnostic Imaging
    Ravi, Mural
    Sanagapati, Siva Sankara Sai
    IEEE ACCESS, 2017, 5 : 24941 - 24947
  • [9] Continuous-flow tubular crystallization in slugs spontaneously induced by hydrodynamics
    Jiang, Mo
    Zhu, Zhilong
    Jimenez, Ernesto
    Papageorgiou, Charles D.
    Waetzig, Josh
    Hardy, Andrew
    Langston, Marianne
    Braatz, Richard D.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 248
  • [10] Continuous-Flow Tubular Crystallization in Slugs Spontaneously Induced by Hydrodynamics
    Jiang, Mo
    Zhu, Zhilong
    Jimenez, Ernesto
    Papageorgiou, Charles D.
    Waetzig, Josh
    Hardy, Andrew
    Langston, Marianne
    Braatz, Richard D.
    CRYSTAL GROWTH & DESIGN, 2014, 14 (02) : 851 - 860