In situ Raman spectroscopy investigation of bioactive glass reactivity: Simulated body fluid solution vs TRIS-buffered solution

被引:85
作者
Bellucci, D. [1 ]
Bolelli, G. [1 ]
Cannillo, V. [1 ]
Cattini, A. [1 ]
Sola, A. [1 ]
机构
[1] Univ Modena & Reggio Emilia, Dipartimento Ingn Mat & Ambiente, I-41125 Modena, Italy
关键词
Raman spectroscopy; Bioactive glasses; Simulated body fluid; TRIS-buffered solution; Hydroxyl-carbonate apatite; APATITES;
D O I
10.1016/j.matchar.2011.07.008
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In the present contribution, the innovative in situ Raman micro-spectroscopy was applied to investigate the in vitro reactivity of various bioactive glasses. All the investigated glasses belonged to the Na(2)O\K(2)O-CaO-P(2)O(5)-SiO(2) system, but contained sensibly different percentages of network modifiers. The glasses were immersed for increasing times, up to 96 h, in simulated body fluid (SBF) and in tris-buffered (TRIS) solution. In this way, two fundamental items were addressed, i.e. the effect of the glass composition and the nature of the soaking fluid on the overall reactivity. As regards the SBF, all the glasses were able to promote the formation of a hydroxyl-carbonate apatite (HCA) surface layer in very short times. The reaction rate was particularly quick for the 45S5 Bioglass (R) and for its potassium-based variant (BioK), however all the glasses could form a continuous HCA layer already after 96 h. The observed difference in reaction kinetics may be due to the glass composition, since the glasses relatively poor in Na ions (BG_Ca) experience slower ion release in the first stages of the HCA formation, while the glasses relatively poor in Ca ions (BG_Na) undergo slower nucleation and growth of HCA. The development of HCA was also observed in TRIS, but the reaction rate was generally slower than in SBF. In fact, while the SBF is a complicated solution supersaturated in apatite, which favours the precipitation of HCA, the TRIS is a simple tris(hydroxymethyl)aminomethane solution in water, which does not provide the ions for the HCA formation. As a consequence, the aforementioned effects due to the glass composition were even more evident in TRIS than in SBF. Nevertheless the TRIS could represent a valuable alternative to the standard SBF whenever a slow reaction rate might be beneficial, such as, for example, in order to better observe the samples evolution. (C) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:1021 / 1028
页数:8
相关论文
共 22 条
[1]  
[Anonymous], BIOCERAMICS
[2]   Micro-Raman and FTIR studies of synthetic and natural apatites [J].
Antonakos, Anastasios ;
Liarokapis, Efthymios ;
Leventouri, Theodora .
BIOMATERIALS, 2007, 28 (19) :3043-3054
[3]   Carbonate assignment and calibration in the raman spectrum of apatite [J].
Awonusi, Ayorinde ;
Morris, Michael D. ;
Tecklenburg, Mary M. J. .
CALCIFIED TISSUE INTERNATIONAL, 2007, 81 (01) :46-52
[4]   A new potassium-based bioactive glass: Sintering behaviour and Possible applications for bioceramic scaffolds [J].
Bellucci, Devis ;
Cannillo, Valeria ;
Sola, Antonella .
CERAMICS INTERNATIONAL, 2011, 37 (01) :145-157
[5]   In situ Raman study to monitor bioactive glasses reactivity [J].
Bonino, Francesca ;
Damin, Alessandro ;
Aina, Valentina ;
Miola, Marta ;
Verne, Enrica ;
Bretcanu, Oana ;
Bordiga, Silvia ;
Zecchina, Adriano ;
Morterra, Claudio .
JOURNAL OF RAMAN SPECTROSCOPY, 2008, 39 (02) :260-264
[6]   Potassium-based composition for a bioactive glass [J].
Cannillo, V. ;
Sola, A. .
CERAMICS INTERNATIONAL, 2009, 35 (08) :3389-3393
[7]   Raman spectroscopic study of bioactive silica based glasses [J].
González, P ;
Serra, J ;
Liste, S ;
Chiussi, S ;
León, B ;
Pérez-Amor, M .
JOURNAL OF NON-CRYSTALLINE SOLIDS, 2003, 320 (1-3) :92-99
[8]  
Hench L.L., 1973, J BIOMEDICAL MAT RES, V4, P25
[9]  
Hench L.L., 1971, Journal of Biomedical Materials Research Symposium, V36, P117, DOI [10.1002/jbm.820050611, DOI 10.1002/JBM.820050611]
[10]   The story of Bioglass® [J].
Hench, Larry L. .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2006, 17 (11) :967-978