Neutron and photon doses in high energy radiotherapy facilities and evaluation of shielding performance by Monte Carlo method

被引:9
|
作者
Ghassoun, J. [1 ]
Senhou, N. [1 ]
Jehouani, A. [1 ]
机构
[1] Fac Sci Semlalia, Dept Phys, EPRA, Marrakech 40000, Morocco
关键词
Radiotherapy; Accelerator; Dose; Neutron; Gamma; MCNP; MEDICAL ELECTRON-ACCELERATORS; MAZE;
D O I
10.1016/j.anucene.2011.06.020
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Medical accelerators operating above 10 MV are a source of undesirable neutron radiations which contaminate the therapeutic photon beam. These photoneutrons can also generate secondary gamma rays which increases undesirable dose to the patient body and to personnel and general public. In this study, the Monte Carlo N-Particle MCNP5 code has been used to model the radiotherapy room of a medical linear accelerator operating at 18 MV and to calculate the neutron and the secondary gamma ray energy spectra and the dose equivalents at various points inside the treatment room and along the maze. To validate our Monte Carlo simulation we compared our results with those evaluated by the recommended analytical methods of IAEA Report No. 47, and with experimental and simulated values published in the literature. After validation, the Monte Carlo simulation has been used to evaluate the shielding performance of the radiotherapy room. The obtained results showed that the use of paraffin wax containing boron carbide, in the lining of the radiotherapy room walls, presents enough effectiveness to reduce both neutron and gamma ray doses inside the treatment room and at the maze entrance. Such evaluation cannot be performed by the analytical methods since room material and wall surface lining are not taken into consideration. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2163 / 2167
页数:5
相关论文
共 50 条
  • [41] Modelling of neutron and photon transport in iron and concrete radiation shieldings by the Monte Carlo method
    Zukauskaite, A.
    Plukiene, R.
    Plukis, A.
    Ridikas, D.
    LITHUANIAN JOURNAL OF PHYSICS, 2007, 47 (01): : 97 - 101
  • [42] Midway forward-adjoint coupling method for neutron and photon Monte Carlo transport
    Delft University of Technology, Interfaculty Reactor Institue, Mekelweg 15, 2629 JB Delft, Netherlands
    不详
    Nucl Sci Eng, 1 (55-72):
  • [43] Experimental investigation on radiation shielding of high performance concrete for nuclear and radiotherapy facilities
    Domanski, Szymon
    Gryzinski, Michal A.
    Maciak, Maciej
    Murawski, Lukasz
    Tulik, Piotr
    Tyminska, Katarzyna
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2016, 22 (02) : 41 - 47
  • [44] Monte Carlo simulation of a high-efficacy composite material: feasibility for neutron and gamma ray shielding of Small Modular Reactor (SMR) facilities
    Mukherjee, B.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (07)
  • [45] Application of the Monte Carlo method to the analysis of doses and shielding around an X-ray fluorescence equipment
    Rodenas, Jose
    Juste, Belen
    Gallardo, Sergio
    Querol, Andrea
    ICRS-13 & RPSD-2016, 13TH INTERNATIONAL CONFERENCE ON RADIATION SHIELDING & 19TH TOPICAL MEETING OF THE RADIATION PROTECTION AND SHIELDING DIVISION OF THE AMERICAN NUCLEAR SOCIETY - 2016, 2017, 153
  • [46] On Network Reliability Evaluation by Monte Carlo Method Using High-Performance Computing
    D. A. Migov
    D. V. Weins
    Lobachevskii Journal of Mathematics, 2023, 44 : 3122 - 3129
  • [47] On Network Reliability Evaluation by Monte Carlo Method Using High-Performance Computing
    Migov, D. A.
    Weins, D. V.
    LOBACHEVSKII JOURNAL OF MATHEMATICS, 2023, 44 (08) : 3122 - 3129
  • [48] SECONDARY NEUTRON DOSES TO PEDIATRIC PATIENTS DURING INTRACRANIAL PROTON THERAPY: MONTE CARLO SIMULATION OF THE NEUTRON ENERGY SPECTRUM AND ITS ORGAN DOSES
    Matsumoto, Shinnosuke
    Koba, Yusuke
    Kohno, Ryosuke
    Lee, Choonsik
    Bolch, Wesley E.
    Kai, Michiaki
    HEALTH PHYSICS, 2016, 110 (04): : 380 - 386
  • [49] Monte Carlo-based energy response studies of diode dosimeters in radiotherapy photon beams
    Arun C.
    Selvam T.P.
    Dinkar V.
    Munshi P.
    Kalra M.S.
    Radiological Physics and Technology, 2013, 6 (1) : 151 - 156
  • [50] Evaluation of Digital Energy Meter Error by Monte Carlo Method
    Peng Xiaojuan
    Wang Lei
    Jia Zhengsen
    Wang Xuewei
    Huang Hongtao
    Liu Lijuan
    2016 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2016), 2016,