Neutron and photon doses in high energy radiotherapy facilities and evaluation of shielding performance by Monte Carlo method

被引:9
|
作者
Ghassoun, J. [1 ]
Senhou, N. [1 ]
Jehouani, A. [1 ]
机构
[1] Fac Sci Semlalia, Dept Phys, EPRA, Marrakech 40000, Morocco
关键词
Radiotherapy; Accelerator; Dose; Neutron; Gamma; MCNP; MEDICAL ELECTRON-ACCELERATORS; MAZE;
D O I
10.1016/j.anucene.2011.06.020
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Medical accelerators operating above 10 MV are a source of undesirable neutron radiations which contaminate the therapeutic photon beam. These photoneutrons can also generate secondary gamma rays which increases undesirable dose to the patient body and to personnel and general public. In this study, the Monte Carlo N-Particle MCNP5 code has been used to model the radiotherapy room of a medical linear accelerator operating at 18 MV and to calculate the neutron and the secondary gamma ray energy spectra and the dose equivalents at various points inside the treatment room and along the maze. To validate our Monte Carlo simulation we compared our results with those evaluated by the recommended analytical methods of IAEA Report No. 47, and with experimental and simulated values published in the literature. After validation, the Monte Carlo simulation has been used to evaluate the shielding performance of the radiotherapy room. The obtained results showed that the use of paraffin wax containing boron carbide, in the lining of the radiotherapy room walls, presents enough effectiveness to reduce both neutron and gamma ray doses inside the treatment room and at the maze entrance. Such evaluation cannot be performed by the analytical methods since room material and wall surface lining are not taken into consideration. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2163 / 2167
页数:5
相关论文
共 50 条
  • [21] The Monte Carlo simulation of neutron shielding performance of boron carbide reinforced with aluminum composites
    Dai Chun-Juan
    Liu Xi-Qin
    Liu Zi-Li
    Liu Bo-Lu
    ACTA PHYSICA SINICA, 2013, 62 (15)
  • [22] Measurement of the contralateral breast photon and neutron dose in breast cancer radiotherapy: A Monte Carlo study
    Bagheri, Hamed
    Farhood, Bagher
    Mahdavi, Seied Rabi
    Shekarchi, Babak
    Manouchehri, Farhad
    Esfandbod, Malahat
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2019, 15 (05) : 1018 - 1023
  • [23] High-performance computing for Monte Carlo radiotherapy calculations
    Downes, P.
    Yaikhom, G.
    Giddy, J. P.
    Walker, D. W.
    Spezi, E.
    Lewis, D. G.
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2009, 367 (1897): : 2607 - 2617
  • [24] Shielding disc backscatter calculations in intraoperative radiotherapy using a Monte Carlo simulation based on the method of energy spectra reconstruction
    Adam Ryczkowski
    Marta Kruszyna-Mochalska
    Bartosz Pawałowski
    Grzegorz Bielęda
    Agata Jodda
    Przemysław Adrich
    Tomasz Piotrowski
    Scientific Reports, 15 (1)
  • [25] The Efficiency of Calculating Photonuclear Reaction On High-Energy Photon Therapy by Monte Carlo Method
    Hirayama, S.
    Fujibuchi, T.
    MEDICAL PHYSICS, 2016, 43 (06) : 3549 - 3549
  • [26] CALCULATION OF DOSE COMPOSITION OUTSIDE SHIELDING OF HIGH-ENERGY ACCELERATORS BY MONTE-CARLO METHOD
    MOKHOV, NV
    FROLOV, VV
    SOVIET ATOMIC ENERGY, 1975, 38 (04): : 288 - 290
  • [27] Monte Carlo dosimetric evaluation of high energy vs low energy photon beams in low density tissues
    Tsiakalos, Miltiadis F.
    Stathakis, Sotirios
    Plataniotis, George A.
    Kappas, Constantin
    Theodorou, Kiki
    RADIOTHERAPY AND ONCOLOGY, 2006, 79 (01) : 131 - 138
  • [28] Photon energy-modulated radiotherapy: Monte Carlo simulation and treatment planning study
    Park, Jong Min
    Kim, Jung-in
    Choi, Chang Heon
    Chie, Eui Kyu
    Kim, Il Han
    Ye, Sung-Joon
    MEDICAL PHYSICS, 2012, 39 (03) : 1265 - 1277
  • [29] Performance and feasibility evaluation for radiation shielding of metal oxides: Monte Carlo simulation
    Da-Eun Kwon
    Dong-Hee Han
    Kyung-Hwan Jung
    Seung-Jae Lee
    Jang-Oh Kim
    Cheol-Ha Baek
    Journal of the Korean Physical Society, 2023, 82 : 813 - 817
  • [30] MONTE CARLO EVALUATION OF THE RADIATION SHIELDING EFFICIENCY OF LAMINATED COMPOSITES UNDER ELECTRON AND PHOTON IRRADIATION
    Borts, B. V.
    Bratchenko, M. I.
    Dyuldya, S. V.
    Marchenko, I. G.
    Sanzharevsky, D. A.
    Tkachenko, V. I.