A Graphenic Biosensor for Real-Time Monitoring of Urea During Dialysis

被引:26
|
作者
Bonini, Andrea [1 ]
Vivaldi, Federico Maria [1 ]
Herrera, Elisa [1 ]
Melai, Bernardo [1 ]
Kirchhain, Arno [1 ]
Sajama, Noemi Violeta Poma [1 ]
Mattonai, Marco [1 ]
Caprioli, Raffaele [2 ]
Lomonaco, Tommaso [1 ]
Di Francesco, Fabio [1 ]
Salvo, Pietro [3 ]
机构
[1] Univ Pisa, Dept Chem & Ind Chem, I-56124 Pisa, Italy
[2] Azienda Osped Univ Pisana, Nephrol Unit, I-56124 Pisa, Italy
[3] Natl Council Res, Inst Clin Physiol, I-56124 Pisa, Italy
关键词
Enzymatic biosensor; reduced graphene oxide; 4-amino benzoic acid; urease; pH; chronic kidney failure; dialysis; urea; CHRONIC KIDNEY-DISEASE; SPENT DIALYSATE; REFERENCE ELECTRODES; PH; BLOOD; TEMPERATURE; ABSORBENCY; REDUCTION; REMOVAL; CANNOT;
D O I
10.1109/JSEN.2020.2966456
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A patient at the fifth stage of chronic kidney disease usually needs dialysis or transplantation. The adequacy of dialysis can be assessed by the dimensionless parameter Kt/V, which depends on the concentration of urea in the blood. Kt/V is usually measured before and after treatment, or by an indirect measurement of dialysis fluid conductivity. For the real-time monitoring of the urea concentration during dialysis, this paper proposes a disposable biosensor that combines a pH sensitive reduced graphene oxide layer functionalized with 4-amino benzoic acid and urease. Urease is immobilized on reduced graphene oxide and catalyzes the hydrolysis of urea into carbon dioxide and ammonia. This catalysis increases the pH value locally and elicits a sensor response. Urea concentration was assessed in the plasma of five dialyzed patients using a potentiometric measurement. The response time was 120 s and the error was 6 +/- 3% compared with standard clinical laboratory analysis.
引用
收藏
页码:4571 / 4578
页数:8
相关论文
共 50 条
  • [31] Wireless biosensor system for real-time cholesterol monitoring in fish "Nile tilapia"
    Yoneyama, Yohei
    Yonemori, Yuki
    Murata, Masataka
    Ohnuki, Hitoshi
    Hibi, Kyoko
    Hayashi, Tetsuhito
    Ren, Huifeng
    Endo, Hideaki
    TALANTA, 2009, 80 (02) : 909 - 915
  • [32] Enhanced bioprocess development and operation by use of real-time biosensor monitoring.
    Bracewell, DG
    Hoare, M
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2004, 227 : U128 - U128
  • [33] Real-time monitoring of fenitrothion in water samples using a silicon nanophotonic biosensor
    Ramirez-Priego, Patricia
    Estevez, M. -Carmen
    Diaz-Luisravelo, Heriberto J.
    Manclus, Juan J.
    Montoya, Angel
    Lechuga, Laura M.
    ANALYTICA CHIMICA ACTA, 2021, 1152
  • [34] Real-time in vivo uric acid biosensor system for biophysical monitoring of birds
    Gumus, A.
    Lee, S.
    Karlsson, K.
    Gabrielson, R.
    Winkler, D. W.
    Erickson, D.
    ANALYST, 2014, 139 (04) : 742 - 748
  • [35] Development of an optical communication type biosensor for real-time monitoring of fish stress
    Shinoda, Ryosuke
    Wu, Haiyun
    Murata, Masataka
    Ohnuki, Hitoshi
    Yoshiura, Yasutoshi
    Endo, Hideaki
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 247 : 765 - 773
  • [36] REAL-TIME MONITORING
    BLACKBUM, JP
    INTENSIVE CARE MEDICINE, 1979, 5 (03) : 158 - 158
  • [37] REAL-TIME MONITORING
    Thayer, Ann M.
    CHEMICAL & ENGINEERING NEWS, 2014, 92 (47) : 8 - 12
  • [38] Real-time monitoring of accommodation during subjective refraction
    Enrique Garcia-Guerra, Carlos
    Martinez-Roda, Joan
    Aldaba, Mikel
    Galera, Sandra
    Aransay, Cristina
    Diaz-Douton, Fernando
    Pujol, Jaume
    Vilaseca, Meritxell
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [40] Real-time tiltmeter monitoring during compaction grouting
    Schuyler, Jeff N.
    Gularte, Francis
    Geotechnical News, 2000, 18 (02):