A Compact Diode Laser Cavity Ring-Down Spectrometer for Atmospheric Measurements of NO3 and N2O5 with Automated Zeroing and Calibration

被引:20
作者
Odame-Ankrah, Charles A. [1 ]
Osthoff, Hans D. [1 ]
机构
[1] Univ Calgary, Dept Chem, Calgary, AB T2N 1N4, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Cavity ring-down spectroscopy; CRDS; Nitrate radical; Dinitrogen pentoxide; Red diode laser; Compact design; Instrumentation; Automated calibration and zeroing; IN-SITU MEASUREMENTS; NOCTURNAL NITROGEN-OXIDES; TEMPERATURE-DEPENDENCE; SPECTROSCOPY; NITRATE; O-3; CHEMISTRY; APPLICABILITY; INSTRUMENT; CLNO2;
D O I
10.1366/11-06384
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A compact rack-mounted cavity ring-down spectrometer (CRDS) for simultaneous measurements of the nocturnal nitrogen oxides NO3 and N2O5 in ambient air is described. The instrument uses a red diode laser to quantify mixing ratios of NO3 (at its absorption maximum at 662 nm) and of N2O5 following its thermal dissociation to NO3 in a second detection channel. The spectrometer is equipped with an automated zeroing and calibration setup to determine effective NO3 absorption cross-sections and NO3 and N2O5 inlet transmission efficiencies. The instrument response was calibrated using simultaneous measurements of NO2, generated by thermal dissociation of N2O5 and/or by titration of NO3 with excess NO, using blue diode laser CRDS at 405 nm. When measuring ambient air, the (2 sigma, 10 s) precision of the red diode CRDS varied between 5 and 8 parts-per-trillion by volume (pptv), which sufficed to quantify N2O5 concentrations under moderately polluted conditions. Sample N2O5 measurements made on a rooftop on the University of Calgary campus in August 2010 are presented. A maximum N2O5 mixing ratio of 130 pptv was observed, corresponding to a steady-state lifetime of less than 50 min. The NO3 mixing ratios were below the detection limit, consistent with their predicted values based on equilibrium calculations. During the measurement period, the instrument response for N2O5 was 70% of the theoretical maximum, rationalized by a slight mismatch of the laser diode output with the NO3 absorption line and a N2O5 inlet transmission efficiency less than unity. Advantages and limitations of the instrument's compact design are discussed.
引用
收藏
页码:1260 / 1268
页数:9
相关论文
共 29 条
  • [21] High-precision measurements of δ2H, δ18O and δ17O in water with the aid of cavity ring-down laser spectroscopy
    Pierchala, Anna
    Rozanski, Kazimierz
    Dulinski, Marek
    Gorczyca, Zbigniew
    Marzec, Michal
    Czub, Robert
    ISOTOPES IN ENVIRONMENTAL AND HEALTH STUDIES, 2019, 55 (03) : 290 - 307
  • [22] Determination of the rate constant of the reaction of NO3 with C2H5I using time-resolved cavity ring-down spectroscopy
    Nakano, Yukio
    Hosho, Yuichi
    Sadamori, Kengo
    Ishiwata, Takashi
    CHEMICAL PHYSICS LETTERS, 2012, 535 : 26 - 29
  • [23] Impact of Residual Water Vapor on the Simultaneous Measurements of Trace CH4 and N2O in Air with Cavity Ring-Down Spectroscopy
    Wei, Qianhe
    Li, Bincheng
    Wang, Jing
    Zhao, Binxing
    Yang, Ping
    ATMOSPHERE, 2021, 12 (02)
  • [24] Large daytime signals of N2O5 and NO3 inferred at 62 amu in a TD-CIMS: chemical interference or a real atmospheric phenomenon?
    Wang, X.
    Wang, T.
    Yan, C.
    Tham, Y. J.
    Xue, L.
    Xu, Z.
    Zha, Q.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2014, 7 (01) : 1 - 12
  • [25] Effect of air composition (N2, O2, Ar, and H2O) on CO2 and CH4 measurement by wavelength-scanned cavity ring-down spectroscopy: calibration and measurement strategy
    Nara, H.
    Tanimoto, H.
    Tohjima, Y.
    Mukai, H.
    Nojiri, Y.
    Katsumata, K.
    Rella, C. W.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2012, 5 (11) : 2689 - 2701
  • [26] Investigation of the ν2+2ν3 Subband in the Overtone Icosad of 13CH4 by Pulsed Supersonic Jet and Diode Laser Cavity Ring-Down Spectroscopy: Partial Rovibrational Analysis and Nuclear Spin Symmetry Conservation
    Bjelobrk, Zoran
    Tanner, Carine Manca
    Quack, Martin
    ZEITSCHRIFT FUR PHYSIKALISCHE CHEMIE-INTERNATIONAL JOURNAL OF RESEARCH IN PHYSICAL CHEMISTRY & CHEMICAL PHYSICS, 2015, 229 (10-12): : 1575 - 1607
  • [27] Line positions and N2-induced line parameters of the 00°3-00°0 band of 14N216O by comb-assisted cavity ring-down spectroscopy
    Liu, G. -L.
    Wang, J.
    Tan, Y.
    Kang, P.
    Bi, Z.
    Liu, A. -W.
    Hu, S. -M.
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2019, 229 : 17 - 22
  • [28] Pressure Broadening of H2O Absorption Lines in the 1.3 μm Region Measured by Continuous Wave-Cavity Ring-Down Spectroscopy: Application in the Trace Detection of Water Vapor in N2, SiH4,CF4, and PH3
    Fiadzomor, Phyllis A. Y.
    Baker, Derek M.
    Keen, Anthony M.
    Grant, Robert B.
    Orr-Ewing, Andrew J.
    APPLIED SPECTROSCOPY, 2008, 62 (12) : 1354 - 1362
  • [29] Atmospheric vertical profiles of O3, N2O, CH4, CCl2F2, and H2O retrieved from external-cavity quantum-cascade laser heterodyne radiometer measurements
    Tsai, Tracy R.
    Rose, Rebecca A.
    Weidmann, Damien
    Wysocki, Gerard
    APPLIED OPTICS, 2012, 51 (36) : 8779 - 8792