Temperature and pH tolerance ratiometric aptasensor: Efficiently self-calibrating electrochemical detection of aflatoxin B1

被引:23
作者
Chen, Ting [1 ]
Li, Yuye [1 ]
Meng, Shuyun [1 ]
Liu, Chang [1 ]
Liu, Dong [1 ]
Dong, Daming [2 ]
You, Tianyan [1 ]
机构
[1] Jiangsu Univ, Sch Agr Engn, Minist Educ, Key Lab Modern Agr Equipment & Technol, Zhenjiang 212013, Jiangsu, Peoples R China
[2] Beijing Acad Agr & Forestry Sci, Natl Engn Res Ctr Intelligent Equipment Agr, Beijing 100097, Peoples R China
基金
中国国家自然科学基金;
关键词
Self-calibration; Single redox reporter; Ratiometric aptasensor; Aflatoxin B1; BIOSENSOR; DNA; SENSORS; ELECTRODE; PLATFORM; SIGNAL; PROBE; IONS;
D O I
10.1016/j.talanta.2022.123280
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ratiometric electrochemical aptasensors based on the two different redox reporters can hardly achieve the efficient self-calibration, as a result of variations between reporters. In this work, we reported a ratiometric electrochemical aptasensor using ferrocene as a single redox reporter (Fc) to achieve self-calibrating electro-chemical detection of aflatoxin B1 (AFB1). The hybrid duplex of Fc-labeled AFB1 aptamer (Fc-Apt) and Fc-labeled assistant DNA (Fc-aDNA) was designed to construct the sensing interface. Such DNA structure adopted the fixed molar ratio (1:1) and locations (the distances to electrode) of these two types of Fc (i.e., Fc-Apt and Fc-aDNA). In this way, the ratio of redox currents from Fc-Apt (IFc-Apt) and Fc-aDNA (IFc-aDNA) kept stable under the varied temperatures (15-40 degrees C) and pH values (4-10). Moreover, values of IFc-Apt and IFc-aDNA under the different conditions can be calculated simply by recording the total current of Fc (IFc-total). For analysis, the recognition of AFB1 by Fc-Apt led to the striping of their complex from the aptasensor, resulting in a decrease in IFc-Apt while IFc-aDNA remained stable. Consequently, the developed aptasensor using the ratio of IFc-Apt/IFc-aDNA as a yardstick offered a linear range of 0.1-10000 pg mL(-1) with a detection limit of 0.012 pg mL(-1) for the detection of AFB1. The applicability of aptasensor was validated by corn sample analysis, which exhibited comparable reliability and accuracy of gold standard method, i.e., HPLC-MS/MS. Our work provided an efficient strategy to fabricate high-performance ratiometric electrochemical aptasensors.
引用
收藏
页数:7
相关论文
共 45 条
[1]   Rapid and on-site simultaneous electrochemical detection of copper, lead and mercury in the Amazon river [J].
Bernalte, Elena ;
Arevalo, Sebastian ;
Perez-Taborda, Jaime ;
Wenk, Jannis ;
Estrela, Pedro ;
Avila, Alba ;
Di Lorenzo, Mirella .
SENSORS AND ACTUATORS B-CHEMICAL, 2020, 307
[2]   Developing an electrochemical sensor for the detection of tert-butylhydroquinone [J].
Cao, Wei ;
Wang, Yong ;
Zhuang, Qianfen ;
Wang, Luyao ;
Ni, Yongnian .
SENSORS AND ACTUATORS B-CHEMICAL, 2019, 293 :321-328
[3]   A novel whole-cell biosensor for the determination of trichloroethylene [J].
Chee, Gab-Joo .
SENSORS AND ACTUATORS B-CHEMICAL, 2016, 237 :836-840
[4]   A reusable ratiometric electrochemical biosensor on the basis of the binding of methylene blue to DNA with alternating AT base sequence for sensitive detection of adenosine [J].
Cui, Lin ;
Lu, Mengfei ;
Li, Ying ;
Tang, Bo ;
Zhang, Chun-yang .
BIOSENSORS & BIOELECTRONICS, 2018, 102 :87-93
[5]   High-Performance Ratiometric Electrochemical Method Based on the Combination of Signal Probe and Inner Reference Probe in One Hairpin-Structured DNA [J].
Deng, Chunyan ;
Pi, Xiaomei ;
Qian, Pin ;
Chen, Xiaoqing ;
Wu, Wuming ;
Xiang, Juan .
ANALYTICAL CHEMISTRY, 2017, 89 (01) :966-973
[6]   Reagentless, Ratiometric Electrochemical DNA Sensors with Improved Robustness and Reproducibility [J].
Du, Yan ;
Lim, Byung Joon ;
Li, Bingling ;
Jiang, Yu Sherry ;
Sessler, Jonathan L. ;
Ellington, Andrew D. .
ANALYTICAL CHEMISTRY, 2014, 86 (15) :8010-8016
[7]   Understanding and Correcting Unwanted Influences on the Signal from Electrochemical Gas Sensors [J].
Farquhar, Anna K. ;
Henshaw, Geoff S. ;
Williams, David E. .
ACS SENSORS, 2021, 6 (03) :1295-1304
[8]   Versatile Electrochemiluminescence and Electrochemical "On-Off" Assays of Methyltransferases and Aflatoxin B1 Based on a Novel Multifunctional DNA Nanotube [J].
Ge, Junjun ;
Zhao, Yu ;
Li, Chunli ;
Jie, Guifen .
ANALYTICAL CHEMISTRY, 2019, 91 (05) :3546-3554
[9]   Fabrication of a novel aptasensor based on three-dimensional reduced graphene oxide/polyaniline/gold nanoparticle composite as a novel platform for high sensitive and specific cocaine detection [J].
Hashemi, Pegah ;
Bagheri, Hasan ;
Afkhami, Abbas ;
Ardakani, Yalda Hosseinzadeh ;
Madrakian, Tayyebeh .
ANALYTICA CHIMICA ACTA, 2017, 996 :10-19
[10]   Influence of ionic strength, pH and aptamer configuration for binding affinity to thrombin [J].
Hianik, Tibor ;
Ostatna, Veronika ;
Sonlajtnerova, Michaela ;
Grman, Igor .
BIOELECTROCHEMISTRY, 2007, 70 (01) :127-133