Electroanalytical detection of Pb, Cd and traces of Cr at micro/nano-structured bismuth film electrodes

被引:58
|
作者
Saturno, Jorge [1 ]
Valera, Danny [1 ]
Carrero, Hermes [1 ]
Fernandez, Lenys [1 ]
机构
[1] Univ Simon Bolivar, Dept Quim, Caracas 1080A, Venezuela
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2011年 / 159卷 / 01期
关键词
Bismuth film electrodes; Micro/nanoparticle; Anodic stripping voltammetry; Adsorptive stripping voltammetry; Aluminum oxide template; ADSORPTIVE STRIPPING VOLTAMMETRY; HEAVY-METALS; NANOPARTICLES; CHROMIUM(VI); VANADIUM; ZN;
D O I
10.1016/j.snb.2011.06.055
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A micro/nanoparticle (mu-NP) bismuth film electrode (BiFE) has been developed for the determination of lead and cadmium by anodic stripping voltammetry (ASV) and trace levels of chromium by adsorptive stripping voltammetry (AdSV). Chromium was detected in a flow cell. Bismuth was electrodeposited on a hydrated aluminum oxide template, which was previously coated on a glassy-carbon (GC) electrode. Then, the template was selectively removed by soaking the electrode in a 0.1 M NaOH solution for 30 min, leaving a dispersed bismuth film covering the electrode surface; such electrodeposits had a particulate appearance, which was observed by scanning electron microscopy (SEM). The voltammetric analyses from a chromium solution on a mu-NPs/BiFE provided a limit of detection (LOD) equal to 0.12 ng L-1 (n = 6) and a slope of 0.27 mu C/ng L-1 (R-2 = 0.9903). The signals registered were more than 50 times higher than the peaks obtained from a conventional BiFE. The analysis of aqueous solutions of Cd and Pb gave also lower LOD and higher sensitivity against the conventional BiFe experiments. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:92 / 96
页数:5
相关论文
共 13 条
  • [1] Effects of Humidity, Temperature and Bismuth Electrodeposition on Electroanalytical Performances of Nafion-coated Printed Electrodes for Cd2+ and Pb2+ Detection
    Colozza, Noemi
    Cacciotti, Ilaria
    Moscone, Danila
    Arduini, Fabiana
    ELECTROANALYSIS, 2020, 32 (02) : 345 - 357
  • [2] Bismuth-tin-film electrodes for Zn(II), Cd(II), and Pb(II) trace analysis
    Finsgar, Matjaz
    Petovar, Barbara
    Vodopivec, Katja
    MICROCHEMICAL JOURNAL, 2019, 145 : 676 - 685
  • [3] Detection of Cd2+ by Square Wave Anodic Stripping Voltammetry Using an Activated Bismuth-film Electrodes
    Yao Mei-Na
    Yang Xian-Jin
    Cui Zhen-Duo
    Zhu Sheng-Li
    Li Zhao-Yang
    Liang Yan-Qin
    JOURNAL OF INORGANIC MATERIALS, 2019, 34 (01) : 91 - 95
  • [4] A study on the utility of bismuth-film electrodes for the determination of In(III) in the presence of Pb(II) and Cd(II) by square wave anodic stripping voltammetry
    Charalambous, A
    Economou, A
    ANALYTICA CHIMICA ACTA, 2005, 547 (01) : 53 - 58
  • [5] Direct Electrodeposition of Carbon Dots Modifying Bismuth Film Electrode for Sensitive Detection of Cd2+ and Pb2+
    Zhang, Hao
    Cui, Jun
    Zeng, Yuxin
    Zhang, Yu
    Pei, Yuansheng
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2022, 169 (01)
  • [6] Mercury-free sono-electroanalytical detection of lead in human blood by use of bismuth-film-modified boron-doped diamond electrodes
    Kruusma, J
    Banks, CE
    Compton, RG
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (04) : 700 - 706
  • [7] Mercury-free sono-electroanalytical detection of lead in human blood by use of bismuth-film-modified boron-doped diamond electrodes
    Jaanus Kruusma
    Craig E. Banks
    Richard G. Compton
    Analytical and Bioanalytical Chemistry, 2004, 379 : 700 - 706
  • [8] Structured and graphitized boron doped diamond electrodes: Impact on electrochemical detection of Cd2+ and Pb2+ ions
    Stenclova, Pavla
    Vyskocil, Vlastimil
    Szabo, Ondrej
    Izak, Tibor
    Potocky, Stepan
    Kromka, Alexander
    VACUUM, 2019, 170
  • [9] A study of bismuth-film electrodes for the detection of trace metals by anodic stripping voltammetry and their application to the determination of Pb and Zn in tapwater and human hair
    Kefala, G
    Economou, A
    Voulgaropoulos, A
    Sofoniou, M
    TALANTA, 2003, 61 (05) : 603 - 610
  • [10] Simultaneous and Sensitive Detection of Cd(II) and Pb(II) Using a Novel Bismuth Film/Ordered Mesoporous Carbon-molecular Wire Modified Graphite Carbon Paste Electrode
    Zhao, Guo
    Wang, Hui
    Liu, Gang
    Wang, Zhiqiang
    ELECTROANALYSIS, 2017, 29 (02) : 497 - 505