Intravascular Optical Coherence Tomography for Characterization of Atherosclerosis with a 1.7 Micron Swept-Source Laser

被引:30
|
作者
Li, Yan [1 ,2 ]
Jing, Joseph [1 ,2 ]
Heidari, Emon [1 ,2 ]
Zhu, Jiang [1 ]
Qu, Yueqiao [1 ,2 ]
Chen, Zhongping [1 ,2 ]
机构
[1] Univ Calif Irvine, Beckman Laser Inst, 1002 Hlth Sci Rd, Irvine, CA 92617 USA
[2] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92697 USA
来源
SCIENTIFIC REPORTS | 2017年 / 7卷
基金
美国国家卫生研究院;
关键词
PLAQUE; ULTRASOUND; IVUS; OCT;
D O I
10.1038/s41598-017-15326-4
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The main cause of acute coronary events, such as thrombosis, is the rupture of atherosclerotic plaques. Typical intravascular optical coherence tomography (IVOCT) imaging systems that utilize a 1.3 mu m swept source laser are often used for identifying fibrous cap thickness of plaques, yet cannot provide adequate depth penetration to resolve the size of the lipid pool. Here, we present a novel IVOCT system with a 1.7 mu m center wavelength swept light source that can readily penetrate deeper into the tissue because of the longer wavelength and allows for better identification of plaques due to the lipid absorption spectrum at 1.7 mu m. Using this system, we have imaged a human coronary artery to evaluate the performance of the novel OCT system and verified the results by hematoxylin and eosin (H&E) histology. The significantly improved imaging depth and better identification sensitivity suggest that the 1.7 mu m OCT system holds great potential that can be further translated for in-vivo applications of atherosclerosis characterization.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] En Face Imaging of Posterior Precortical Vitreous Pockets Using Swept-Source Optical Coherence Tomography
    Itakura, Hirotaka
    Kishi, Shoji
    Li, Danjie
    Akiyama, Hideo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (05) : 2898 - 2900
  • [42] Macular Choroidal Thickness and Volume in Healthy Pediatric Individuals Measured by Swept-Source Optical Coherence Tomography
    Nagasawa, Toshihiko
    Mitamura, Yoshinori
    Katome, Takashi
    Shinomiya, Kayo
    Naito, Takeshi
    Nagasato, Daisuke
    Shimizu, Yukiko
    Tabuchi, Hitoshi
    Kiuchi, Yoshiaki
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (10) : 7068 - 7074
  • [43] Swept-source optical coherence tomography angiography vitreo-retinal segmentation in proliferative diabetic retinopathy
    Papayannis, Alessandro
    Tsamis, Emmanouil
    Stringa, Francesco
    Iacono, Pierluigi
    Parodi, Maurizio Battaglia
    Stanga, Paulo Eduardo
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (04) : 1925 - 1932
  • [44] Ability of Swept-Source Optical Coherence Tomography to Detect Retinal and Choroidal Changes in Patients with Multiple Sclerosis
    Garcia-Martin, Elena
    Jarauta, Laura
    Vilades, Elisa
    Ramon Ara, Jose
    Martin, Jesus
    Polo, Vicente
    Manuel Larrosa, Jose
    Emilio Pablo, Luis
    Satue, Maria
    JOURNAL OF OPHTHALMOLOGY, 2018, 2018
  • [45] Volumetric analysis of breast cancer tissues using machine learning and swept-source optical coherence tomography
    Butola, Ankit
    Ahmad, Azeem
    Dubey, Vishesh
    Srivastava, Vishal
    Qaiser, Darakhshan
    Srivastava, Anurag
    Senthilkumaran, Paramsivam
    Mehta, Dalip Singh
    APPLIED OPTICS, 2019, 58 (05) : A135 - A141
  • [46] On-axis full-field swept-source optical coherence tomography for murine retinal imaging
    Meleppat, Ratheesh K.
    Valente, Denise
    Lee, Soohyun
    Jonnal, Ravi S.
    Doble, Nathan
    Zawadzki, Robert J.
    OPTICS LETTERS, 2024, 49 (16) : 4630 - 4633
  • [47] Iridotrabecular Contact Evaluated With Anterior-Segment Swept-Source Optical Coherence Tomography and Ultrasound Biomicroscopy in Narrow Angle Eyes
    Mishima, K.
    Tomidokoro, A.
    Suramethakul, P.
    Mataki, N.
    Kurita, N.
    Araie, M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [48] Comparative Analysis of Swept-Source Optical Coherence Tomography and Partial Coherence Interferometry Biometers in the Prediction of Cataract Surgery Refractive Outcomes
    Cummings, Arthur B.
    Naughton, Stephanie
    Coen, Ann-Marie
    Brennan, Elizabeth
    Kelly, Gabrielle E.
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 4209 - 4220
  • [49] 400 Hz Volume Rate Swept-Source Optical Coherence Tomography at 1060 nm Using a KTN Deflector
    Jimenez, Alejandro Martinez
    Grelet, Sacha
    Tsatourian, Veronika
    Montague, Patrick Bowen
    Bradu, Adrian
    Podoleanu, Adrian
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2022, 34 (23) : 1277 - 1280
  • [50] Spatiotemporal optical coherence (STOC) manipulation suppresses coherent cross-talk in full-field swept-source optical coherence tomography
    Borycki, Dawid
    Hamkalo, Michal
    Nowakowski, Maciej
    Szkulmowski, Maciej
    Wojtkowski, Maciej
    BIOMEDICAL OPTICS EXPRESS, 2019, 10 (04): : 2032 - 2054