Dosimetric effects of bolus and lens shielding in treating ocular lymphomas with low-energy electrons

被引:2
作者
Young, Lori [1 ]
Wootton, Landon S. [1 ]
Kalet, Alan M. [1 ]
Gopan, Olga [1 ,2 ]
Yang, Fei [1 ,3 ]
Day, Samuel [1 ]
Banitt, Michael [4 ]
Liao, Jay J. [1 ]
机构
[1] Univ Washington, Dept Radiat Oncol, Seattle, WA 98195 USA
[2] Northwest Med Phys Grp, Lynnwood, WA 33136 USA
[3] Univ Miami, Dept Radiat Oncol, Miami, FL 33136 USA
[4] Univ Washington, Dept Ophthalmol, Seattle, WA 98195 USA
关键词
Lens shielding; Bolus; Dosimetry; Ocular lymphoma; RADIOCHROMIC FILM DOSIMETRY; RADIATION-THERAPY; ADNEXAL LYMPHOMA; EYE LENS; TISSUE; RADIOTHERAPY; CONJUNCTIVAL; PROTOCOL; FIELD;
D O I
10.1016/j.meddos.2018.01.005
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Radiation therapy is an effective treatment for primary orbital lymphomas. Lens shielding with electrons can reduce the risk of high-grade cataracts in patients undergoing treatment for superficial tumors. This work evaluates the dosimetric effects of a suspended eye shield, placement of bolus, and varying electron energies. Film (GafChromic EBT3) dosimetry and relative output factors were measured for 6, 8, and 10 MeV electron energies. A customized 5-cm diameter circle electron orbital cutout was constructed for a 6 x 6-cm applicator with a suspended lens shield (8-mm diameter Cerrobend cylinder, 2.2-cm length). Point doses were measured using a scanning electron diode in a solid water phantom at depths representative of the anterior and posterior lens. Depth dose profiles were compared for 0-mm, 3-mm, and 5-mm bolus thicknesses. At 5 mm (the approximate distance of the anterior lens from the surface of the cornea), the percent depth dose under the suspended lens shield was reduced to 15%, 15%, and 14% for electron energies 6, 8, and 10 MeV, respectively. Applying bolus reduced the benefit of lens shielding by increasing the estimated doses under the block to 27% for 3-mm and 44% for 5-mm bolus for a 6 MeV incident electron beam. This effect is minimized with 8 MeV electron beams where the corresponding values were 15.5% and 18% for 3-mm and 5-mm bolus. Introduction of a 7-mm hole in 5-mm bolus to stabilize eye motion during treatment altered lens doses by about 1%. Careful selection of electron energy and consideration of bolus effects are needed to account for electron scatter under a lens shield. (C) 2018 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:35 / 42
页数:8
相关论文
共 35 条
[11]   LOCALIZED ORBITAL MUCOSA-ASSOCIATED LYMPHOMA TISSUE LYMPHOMA MANAGED WITH PRIMARY RADIATION THERAPY: EFFICACY AND TOXICITY [J].
Goda, Jayant Sastri ;
Le, Lisa W. ;
Lapperriere, Normand J. ;
Millar, Barbara-Ann ;
Payne, David ;
Gospodarowicz, Mary K. ;
Wells, Woodrow ;
Hodgson, David C. ;
Sun, Alexander ;
Simpson, Rand ;
Tsang, Richard W. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (04) :E659-E666
[12]   EYE LENS PROTECTION IN TREATMENT OF RETINOBLASTOMA WITH HIGH-ENERGY ELECTRONS [J].
GRIEM, ML ;
ERNEST, JT ;
ROZENFEL.ML ;
NEWELL, FW .
RADIOLOGY, 1968, 90 (02) :351-+
[13]   Analysis of facial skin thickness: Defining the relative thickness index [J].
Ha, RY ;
Nojima, K ;
Adams, WP ;
Brown, SA .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2005, 115 (06) :1769-1773
[14]   Localized Ocular Adnexal Mucosa-Associated Lymphoid Tissue Lymphoma Treated With Radiation Therapy: A Long-Term Outcome in 86 Patients With 104 Treated Eyes [J].
Harada, Ken ;
Murakami, Naoya ;
Kitaguchi, Mayuka ;
Sekii, Shuhei ;
Takahashi, Kana ;
Yoshio, Kotaro ;
Inaba, Koji ;
Morota, Madoka ;
Ito, Yoshinori ;
Sumi, Minako ;
Suzuki, Shigenobu ;
Tobinai, Kensei ;
Uno, Takashi ;
Itami, Jun .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 88 (03) :650-654
[15]   LONG-TERM OUTCOME AND PATTERNS OF FAILURE IN PRIMARY OCULAR ADNEXAL MUCOSA-ASSOCIATED LYMPHOID TISSUE LYMPHOMATREATED WITH RADIOTHERAPY [J].
Hashimoto, Naoki ;
Sasaki, Ryohei ;
Nishimura, Hideki ;
Yoshida, Kenji ;
Miyawaki, Daisuke ;
Nakayama, Masao ;
Uehara, Kazuyuki ;
Okamoto, Yoshiaki ;
Ejima, Yasuo ;
Azumi, Atsushi ;
Matsui, Toshimitsu ;
Sugimura, Kazuro .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (04) :1509-1514
[16]   RADIATION-DOSE TO THE LENS AND CATARACT FORMATION [J].
HENK, JM ;
WHITELOCKE, RAF ;
WARRINGTON, AP ;
BESSELL, EM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (05) :815-820
[17]   2 SPECIAL APPLICATIONS OF HIGH-ENERGY ELECTRON BEAMS [J].
HULTBERG, S ;
WALSTAM, R ;
ASARD, PE .
ACTA RADIOLOGICA-THERAPY PHYSICS BIOLOGY, 1965, 3 (04) :287-&
[18]   RADIATION-THERAPY OF CONJUNCTIVAL AND ORBITAL LYMPHOID TUMORS [J].
JEREB, B ;
LEE, H ;
JAKOBIEC, FA ;
KUTCHER, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1984, 10 (07) :1013-1019
[19]   Task Group 142 report: Quality assurance of medical accelerators [J].
Klein, Eric E. ;
Hanley, Joseph ;
Bayouth, John ;
Yin, Fang-Fang ;
Simon, William ;
Dresser, Sean ;
Serago, Christopher ;
Aguirre, Francisco ;
Ma, Lijun ;
Arjomandy, Bijan ;
Liu, Chihray ;
Sandin, Carlos ;
Holmes, Todd .
MEDICAL PHYSICS, 2009, 36 (09) :4197-4212
[20]   Primary radiotherapy for localized orbital malt lymphoma [J].
Le, QT ;
Eulau, SM ;
George, TI ;
Hildebrand, R ;
Warnke, RA ;
Donaldson, SS ;
Hoppe, RT .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (03) :657-663