Collarless polished tapered stem - Clinical and radiological results at a minimum of ten years' follow-up

被引:46
作者
Yates, P. J. [1 ]
Burston, B. J. [1 ]
Whitley, E. [1 ]
Bannister, G. C. [1 ]
机构
[1] Avon Orthopaed Ctr, Bristol, Avon, England
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2008年 / 90B卷 / 01期
关键词
D O I
10.1302/0301-620X.90B1.19546
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We retrospectively reviewed 175 patients (191 hips) who had undergone primary cemented total hip replacement between November 1992 and November 1995 using a collarless polished double-tapered femoral component after a minimum of ten years (mean 11.08; 10 to 12.8). All stems were implanted using contemporary cementing techniques with a distal cement restrictor, pressurised lavage, retrograde cementing with a gun and proximal pressurisation. Clinical outcome was assessed using the Harris Hip score. Radiological analysis was performed on calibrated plain radiographs taken in two planes. Complete radiological data on 110 patients (120 hips) and clinical follow-up on all the surviving 111 patients (122 hips) was available. The fate of all the hips was known. At final follow-up, the mean Harris Hip score was 86 (47 to 100), and 87 of 116 patients (75%) had good or excellent scores. Survival with revision of the stem for aseptic loosening as the endpoint was 100%; and survival with revision of the stem for any reason was 95.9% (95% confidence interval 87.8 to 96.8) at ten years. All the stems subsided vertically at the stem-cement interface in a predictable pattern, at an overall mean rate of 0.18 mm per year (0.02 to 2.16), but with a mean rate of 0.80 mm (0.02 to 2.5) during the first year. The mean total subsidence was 1.95 mm (0.21 to 24). Only three stems loosened at the cement-bone interface. There was excellent preservation of proximal femoral bone stock. There was a high incidence of Brooker III and IV heterotopic ossification affecting 25 patients (22%). The collarless polished tapered stem has an excellent clinical and radiological outcome at a minimum of ten years' follow-up. The pattern and magnitude of subsidence of the stem within the cement mantle occurred in a predictable pattern, consistent with the design philosophy.
引用
收藏
页码:16 / 22
页数:7
相关论文
共 46 条
  • [1] [Anonymous], 1979, CLIN ORTHOP RELAT RE
  • [2] BANNISTER G, 1988, ORTHOP CLIN N AM, V19, P567
  • [3] IMPROVED CEMENTING TECHNIQUES AND FEMORAL COMPONENT LOOSENING IN YOUNG-PATIENTS WITH HIP-ARTHROPLASTY - A 12-YEAR RADIOGRAPHIC REVIEW
    BARRACK, RL
    MULROY, RD
    HARRIS, WH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (03): : 385 - 389
  • [4] Ten-year survival of the MS-30 matt-surfaced cemented stem
    Berli, BJ
    Schäfer, D
    Morscher, EW
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (07): : 928 - 933
  • [5] Dependency of cement mantle thickness on femoral stem design and centralizer
    Breusch, SJ
    Lukoschek, M
    Kreutzer, J
    Brocai, D
    Gruen, TA
    [J]. JOURNAL OF ARTHROPLASTY, 2001, 16 (05) : 648 - 657
  • [6] ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION
    BROOKER, AF
    BOWERMAN, JW
    ROBINSON, RA
    RILEY, LH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) : 1629 - 1632
  • [7] CHARNLEY J, 1965, J Bone Joint Surg Br, V47, P354
  • [8] Primary exeter total hip arthroplasty in patients with small femurs - A minimal of 10 years follow-up
    Chiu, KH
    Shen, WY
    Cheung, KW
    Tsui, HF
    [J]. JOURNAL OF ARTHROPLASTY, 2005, 20 (03) : 275 - 281
  • [9] Primary hybrid total hip replacement, performed with insertion of the acetabular component without cement and a precoat femoral component with cement - An average ten-year follow-up study
    Clohisy, JC
    Harris, WH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (02) : 247 - 255
  • [10] DELEE JG, 1976, CLIN ORTHOP RELAT R, P20