Modified Dual-Energy Algorithm for Calcified Plaque Removal Evaluation in Carotid Computed Tomography Angiography and Comparison With Digital Subtraction Angiography

被引:54
作者
Mannil, Manoj [1 ]
Ramachandran, Jaychandran [2 ,3 ]
de Martini, Ilaria Vittoria [1 ,2 ]
Wegener, Susanne [4 ]
Schmidt, Bernhard [5 ,6 ]
Flohr, Thomas [5 ]
Krauss, Bernhard [5 ]
Valavanis, Antonios [2 ]
Alkadhi, Hatem [1 ]
Winklhofer, Sebastian [2 ]
机构
[1] Univ Zurich, Inst Diagnost & Intervent Radiol, Univ Hosp Zurich, Zurich, Switzerland
[2] Univ Zurich, Dept Neuroradiol, Univ Hosp Zurich, Zurich, Switzerland
[3] Vikram Hosp, Dept Neurosci, Bangalore, Karnataka, India
[4] Univ Zurich, Univ Hosp Zurich, Dept Neurol, Zurich, Switzerland
[5] Siemens Healthcare GmbH, Erlangen, Germany
[6] Univ Erlangen Nurnberg, Inst Med Phys, Erlangen, Germany
关键词
carotid artery stenosis; computed tomography; dual energy; algorithm; blooming; calcium; artifacts; CT ANGIOGRAPHY; SUBTRACTION-ANGIOGRAPHY; BONE REMOVAL; IMAGE QUALITY; STENOSIS; OPTIMIZATION; AGREEMENT; STROKE; IMPACT;
D O I
10.1097/RLI.0000000000000391
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: Computed tomography angiography (CTA) is a valuable tool for the assessment of carotid artery stenosis. However, blooming artifacts from calcified plaques might result in an overestimation of the stenosis grade. The aim of this study was to investigate a new dual-energy computed tomography (DECT) technique with a modified 3-material decomposition algorithm for calcium removal in extracranial carotid artery stenosis. Materials and Methods: In this retrospective, institutional review board-approved study, 30 calcified carotid plaques in 22 patients (15 men; mean age, 73 +/- 10 years) with clinical suspicion of stroke were included. Dual-energy computed tomography image data were obtained using second-generation dual-source CT with tube volt-ages at 80 and 140Sn kVp. Conventional CTA and virtual noncalcium (VNCa) images using the modified DECT algorithm were reconstructed. By assessing spectral characteristics, the modified DECT algorithm allows for a selective removal of calcium independent of blooming. Two independent and blinded readers evaluated subjective image quality, blooming artifacts, amount of (residual) calcification, and performed stenosis measurements according to the North American Symptomatic Carotid Endarterectomy Trial (NASCET) criteria. Differences were tested using a pairwise sign test. Paired sample t tests with Bonferroni correction (P < 0.017) and Bland-Altman analyses were used to test for differences in carotid stenosis measurements between VNCa and conventional CTA using digital subtraction angiography (DSA) as the standard of reference. Results: Subjective image quality was similar among conventional CTA and VNCa image data sets (P = 0.82), whereas blooming artifacts were significantly reduced in VNCa images compared with conventional CTA (P < 0.001). Residual calcifications in VNCa images were absent in 11 (37%), minor in 12 (40%), medium sized in 2 (7%), and large in 5 (17%) arteries. Stenosis measurements differed significantly between VNCa (mean NASCET stenosis: 27% +/- 20%) and conventional CTA images (mean NASCET stenosis: 39% +/- 16%; P < 0.001) and between conventional CTA and DSA (23% +/- 16%, P < 0.001). No significant differences in stenosis measurements were observed between VNCa and DSA (P = 0.189), with narrow limits of agreement (mean difference +/- 1.96 standard deviations: -4.7%, -35.1%, and 25.7%). Conclusions: Amodified 3-material decomposition DECT algorithm for calcium removal was introduced, which allows for an accurate removal of calcified carotid plaques in extracranial carotid artery disease. The algorithm might overcome the problem of overestimation of calcified stenosis due to blooming artifacts in conventional CTA.
引用
收藏
页码:680 / 685
页数:6
相关论文
共 24 条
  • [1] Stroke Caused by Extracranial Disease
    Barrett, Kevin M.
    Brott, Thomas G.
    [J]. CIRCULATION RESEARCH, 2017, 120 (03) : 496 - 501
  • [2] Image Fusion in Dual Energy Computed Tomography Effect on Contrast Enhancement, Signal-to-Noise Ratio and Image Quality in Computed Tomography Angiography
    Behrendt, Florian F.
    Schmidt, Bernhard
    Plumhans, Cedric
    Keil, Sebastian
    Woodruff, Seth G.
    Ackermann, Diana
    Muehlenbruch, Georg
    Flohr, Thomas
    Guenther, Rolf W.
    Mahnken, Andreas H.
    [J]. INVESTIGATIVE RADIOLOGY, 2009, 44 (01) : 1 - 6
  • [3] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [4] Clinical evaluation of dual-energy bone removal in CT angiography of the head and neck: comparison with conventional bone-subtraction CT angiography
    Deng, K.
    Liu, C.
    Ma, R.
    Sun, C.
    Wang, X. -m.
    Ma, Z. -t.
    Sun, X. -l.
    [J]. CLINICAL RADIOLOGY, 2009, 64 (05) : 534 - 541
  • [5] Evaluation of carotid stenosis using CT angiography in the initial evaluation of stroke and TIA
    Josephson, SA
    Bryant, SO
    Mak, HK
    Johnston, SC
    Dillon, WP
    Smith, WS
    [J]. NEUROLOGY, 2004, 63 (03) : 457 - 460
  • [6] Dual-Energy Computed Tomography Angiography of the Head and Neck With Single-Source Computed Tomography: A New Technical (Split Filter) Approach for Bone Removal
    Kaemmerer, Nadine
    Brand, Michael
    Hammon, Matthias
    May, Matthias
    Wuest, Wolfgang
    Krauss, Bernhard
    Uder, Michael
    Lell, Michael M.
    [J]. INVESTIGATIVE RADIOLOGY, 2016, 51 (10) : 618 - 623
  • [7] Dual-Source Dual-Energy CT Angiography of the Supra-Aortic Arteries with Tin Filter: Impact of Tube Voltage Selection
    Korn, Andreas
    Bender, Benjamin
    Schabel, Christoph
    Bongers, Malte
    Ernemann, Ulrike
    Claussen, Claus
    Thomas, Christoph
    [J]. ACADEMIC RADIOLOGY, 2015, 22 (06) : 708 - 713
  • [8] Krauss B, 2016, MODIFIED DUAL ENERGY
  • [9] Krauss B, 2015, INVEST RADIOL, V50, P114, DOI 10.1097/RLI.0000000000000109
  • [10] An Image-Domain Contrast Material Extraction Method for Dual-Energy Computed Tomography
    Lambert, Jack W.
    Sun, Yuxin
    Gould, Robert G.
    Ohliger, Michael A.
    Li, Zhixi
    Yeh, Benjamin M.
    [J]. INVESTIGATIVE RADIOLOGY, 2017, 52 (04) : 245 - 254