A recirculating-flow fluorescent oxygen sensor

被引:5
作者
Towe, BC [1 ]
Flechsig, S [1 ]
Spaulding, G [1 ]
机构
[1] NASA,JOHNSON SPACE CTR,HOUSTON,TX 77059
关键词
oxygen sensor; fluorescent biosensor;
D O I
10.1016/0956-5663(96)85931-8
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An immersible oxygen sensor was constructed by circulating small quantities of ruthenium tris-(2,2'-bipyridyl) II dichloride oxygen-sensitive fluorescent dye through a loop of oxygen-permeable silicone tubing immersed in test medium. The fluroescence intensity of the dye was subsequently measured as it exited the flow loop and related to oxygen tension. This method of measuring the oxygen tension, through diffusive transport to a flowing stream of dye and recirculating it in the sensor, has been found to give a stable response and relatively long sensor lifetime without major recalibration. The sensor showed good stability over at least a week's duration and showed no degradation due to leaching of the dye through membranes or photobleaching that commonly affects fluorescent sensors with immobilized chemistries. (C) 1996 Elsevier Science Limited
引用
收藏
页码:799 / 803
页数:5
相关论文
共 11 条
  • [1] OPTICAL FLUORESCENCE AND ITS APPLICATION TO AN INTRAVASCULAR BLOOD-GAS MONITORING-SYSTEM
    GEHRICH, JL
    LUBBERS, DW
    OPITZ, N
    HANSMANN, DR
    MILLER, WW
    TUSA, JK
    YAFUSO, M
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (02) : 117 - 132
  • [2] COMBINATION OF MICRODIALYSIS AND GLUCOSENSOR PERMITS CONTINUOUS (ON LINE) SC GLUCOSE MONITORING IN A PATIENT OPERATED DEVICE .1. INVITRO EVALUATION
    KECK, FS
    KERNER, W
    MEYERHOFF, C
    ZIER, H
    PFEIFFER, EF
    [J]. HORMONE AND METABOLIC RESEARCH, 1991, 23 (12) : 617 - 618
  • [3] KISSINGER CB, 1990, AM LAB, V22, P94
  • [4] INVIVO CONTINUOUS MONITORING OF GLUCOSE BY MICRODIALYSIS AND A GLUCOSE BIOSENSOR
    MASCINI, M
    MOSCONE, D
    BERNARDI, L
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1992, 6 (1-3) : 143 - 145
  • [5] FIBER-OPTIC PROBE FOR INVIVO MEASUREMENT OF OXYGEN PARTIAL-PRESSURE
    PETERSON, JI
    FITZGERALD, RV
    BUCKHOLD, DK
    [J]. ANALYTICAL CHEMISTRY, 1984, 56 (01) : 62 - 67
  • [6] Stern O, 1919, PHYS Z, V20, P183
  • [7] OPTICAL SENSORS .34. FIBER OPTIC GLUCOSE BIOSENSOR WITH AN OXYGEN OPTRODE AS THE TRANSDUCER
    TRETTNAK, W
    LEINER, MJP
    WOLFBEIS, OS
    [J]. ANALYST, 1988, 113 (10) : 1519 - 1523
  • [8] Wolfbeis O. S., 1988, Proceedings of the SPIE - The International Society for Optical Engineering, V906, P42, DOI 10.1117/12.945253
  • [9] FIBER-OPTIC FLUOROSENSOR FOR OXYGEN AND CARBON-DIOXIDE
    WOLFBEIS, OS
    WEIS, LJ
    LEINER, MJP
    ZIEGLER, WE
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (19) : 2028 - 2030
  • [10] WOLFBEIS OS, 1991, FIBER OPTIC CHEM SEN, V2