Soft x-ray tomography measurements in the Wendelstein 7-X stellarator

被引:25
作者
Brandt, C. [1 ]
Schilling, J. [1 ]
Thomsen, H. [1 ]
Broszat, T. [1 ]
Laube, R. [1 ]
Schroeder, T. [1 ]
Andreeva, T. [1 ]
Beurskens, M. N. A. [1 ]
Bozhenkov, S. A. [1 ]
Brunner, K. J. [1 ]
Card, A. [1 ]
Cordes, C. [1 ]
Damm, H. [1 ]
Fuchert, G. [1 ]
Gallowski, K. [1 ]
Gutzmann, R. [1 ]
Knauer, J. [1 ]
Laqua, H. P. [1 ]
Marquardt, M. [1 ]
Nelde, Ph [1 ]
Neuner, U. [1 ]
Pasch, E. [1 ]
Rahbarnia, K. [1 ]
Recknagel, J. [1 ]
Schuelke, M. [1 ]
Scott, E. R. [1 ]
Sieber, T. [1 ]
机构
[1] Max Planck Inst Plasma Phys, Wendelsteinstr 1, D-17491 Greifswald, Germany
关键词
x-ray; tomography; XMCTS; stellarator; Wendelstein; W7-X; DIAGNOSTICS;
D O I
10.1088/1361-6587/ab630d
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
The soft x-ray tomography diagnostic in the stellarator Wendelstein 7-X consists of twenty pinhole cameras, up-down symmetrically arranged in a poloidal, triangular cross-section of the plasma vessel. The x-ray emissivity is measured with 16 bit amplitude resolution at 2 MHz sampling rate along 360 lines-of-sight by silicon photodiode arrays. In the recent operation campaign data acquisition (DAQ) has been working reliable for the conducted plasma pulse lengths <1 min, however the DAQ system are ready for the foreseen 30 min plasma pulse lengths of upcoming campaigns. The bandwidth of the preamplifiers is 200 kHz and the sensitive energy range is approximately 1-12 keV. The measurements indicate the up-down symmetric emissivity distribution in the triangular poloidal cross-section. First tomographic reconstructions of different magnetic field configurations are consistent with the theoretically calculated flux surface topology.
引用
收藏
页数:12
相关论文
共 32 条
  • [1] Andreeva T, 2019, FUSION ENG DES
  • [2] [Anonymous], 2019, XCOM: Photon Cross Sections Database
  • [3] [Anonymous], 2009, XRAY DATA BOOKLET
  • [4] X-ray tomography on the TCV tokamak
    Anton, M
    Weisen, H
    Dutch, MJ
    vonderLinden, W
    Buhlmann, F
    Chavan, R
    Marletaz, B
    Marmillod, P
    Paris, P
    [J]. PLASMA PHYSICS AND CONTROLLED FUSION, 1996, 38 (11) : 1849 - 1878
  • [5] RELATIVE CALIBRATION OF PHOTODIODES IN THE SOFT-X-RAY SPECTRAL RANGE
    ANTON, M
    DUTCH, MJ
    WEISEN, H
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (07) : 3762 - 3769
  • [6] Pellet fueling experiments in Wendelstein 7-X
    Baldzuhn, J.
    Damm, H.
    Beidler, C. D.
    McCarthy, K.
    Panadero, N.
    Biedermann, C.
    Bozhenkov, S. A.
    Brunner, K. J.
    Fuchert, G.
    Kazakov, Y.
    Beurskensl, M.
    Dibon, M.
    Geiger, J.
    Grulke, O.
    Hoefel, U.
    Klinger, T.
    Koechl, F.
    Knauer, J.
    Kocsis, G.
    Kornejew, P.
    Lang, P. T.
    Langenberg, A.
    Laqua, H.
    Pablant, N. A.
    Pasch, E.
    Pedersen, T. S.
    Ploeckl, B.
    Rahbarnia, K.
    Schlisio, G.
    Scott, E. R.
    Stange, T.
    von Stechow, A.
    Szepesi, T.
    Turkin, Y.
    Wagner, F.
    Winters, V
    Wurden, G.
    Zhang, D.
    [J]. PLASMA PHYSICS AND CONTROLLED FUSION, 2019, 61 (09)
  • [7] Application of AXUV diode detectors at ASDEX Upgrade
    Bernert, M.
    Eich, T.
    Burckhart, A.
    Fuchs, J. C.
    Giannone, L.
    Kallenbach, A.
    McDermott, R. M.
    Sieglin, B.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (03)
  • [8] Installation of the soft X-ray multi-camera tomography system (XMCTS) in the Wendelstein 7-X stellarator
    Brandt, C.
    Broszat, T.
    Thomsen, H.
    Laube, R.
    Marquardt, M.
    Franz, P.
    Schuelke, M.
    Sieber, T.
    Weissflog, S.
    [J]. FUSION ENGINEERING AND DESIGN, 2017, 123 : 887 - 891
  • [9] D-TACQ Solutions Ltd, HIGH PERF SIM DAT AC
  • [10] SOFT-X-RAY SPECTROSCOPIC DIAGNOSTICS OF LABORATORY PLASMAS
    DEMICHELIS, C
    MATTIOLI, M
    [J]. NUCLEAR FUSION, 1981, 21 (06) : 677 - 754