Assessing the detectability of antioxidants in two-dimensional high-performance liquid chromatography

被引:3
作者
Bassanese, Danielle N. [1 ]
Conlan, Xavier A. [1 ]
Barnett, Neil W. [1 ]
Stevenson, Paul G. [1 ]
机构
[1] Deakin Univ, Sch Life & Environm Sci, Ctr Chem & Biotechnol, Geelong, Vic 3217, Australia
基金
澳大利亚研究理事会;
关键词
Antioxidants; Countergradient; Limit of detection; Solvent strength mismatch; Two-dimensional high-performance liquid chromatography; TANDEM MASS-SPECTROMETRY; DIODE-ARRAY DATA; STEVIA-REBAUDIANA; MOBILE-PHASE; QUANTIFICATION; PROTEOMICS; INJECTION; PEAKS; 2ND-DIMENSION; COLUMNS;
D O I
10.1002/jssc.201500054
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper explores the analytical figures of merit of two-dimensional high-performance liquid chromatography for the separation of antioxidant standards. The cumulative two-dimensional high-performance liquid chromatography peak area was calculated for 11 antioxidants by two different methodsthe areas reported by the control software and by fitting the data with a Gaussian model; these methods were evaluated for precision and sensitivity. Both methods demonstrated excellent precision in regards to retention time in the second dimension (%RSD below 1.16%) and cumulative second dimension peak area (%RSD below 3.73% from the instrument software and 5.87% for the Gaussian method). Combining areas reported by the high-performance liquid chromatographic control software displayed superior limits of detection, in the order of 1 x 10(-6) M, almost an order of magnitude lower than the Gaussian method for some analytes. The introduction of the countergradient eliminated the strong solvent mismatch between dimensions, leading to a much improved peak shape and better detection limits for quantification.
引用
收藏
页码:1642 / 1648
页数:7
相关论文
共 50 条
  • [21] Fully automated micro- and nanoscale one- or two-dimensional high-performance liquid chromatography system for liquid chromatography-mass spectrometry compatible with non-volatile salts for ion exchange chromatography
    Masuda, J
    Maynard, DA
    Nishimura, M
    Uedac, T
    Kowalak, JA
    Markey, SP
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1063 (1-2) : 57 - 69
  • [22] STATE OF THE ART TWO-DIMENSIONAL LIQUID CHROMATOGRAPHY: FUNDAMENTAL CONCEPTS, INSTRUMENTATION, AND APPLICATIONS
    Mogollon, Noroska G. S.
    de Lima, Paula F.
    Gama, Mariana R.
    Furlan, Mayra F.
    Braga, Soraia C. G. N.
    Prata, Paloma S.
    Jardim, Isabel C. S. F.
    Augusto, Fabio
    QUIMICA NOVA, 2014, 37 (10): : 1680 - 1691
  • [23] Advanced applications of two-dimensional liquid chromatography in quantitative analysis of natural products
    Lu, Yang
    Qin, Qiubing
    Pan, Juan
    Deng, Shuqi
    Wang, Shengpeng
    Li, Qiu
    Cao, Jiliang
    JOURNAL OF CHROMATOGRAPHY A, 2025, 1743
  • [24] Assessing the feasibility of stationary-phase-assisted modulation for two-dimensional liquid-chromatography separations
    den Uijl, Mimi J.
    Roeland, Tim
    Bos, Tijmen S.
    Schoenmakers, Peter J.
    van Bommel, Maarten R.
    Pirok, Bob W. J.
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1679
  • [25] Determination of phenylalanine enantiomers in the plasma and urine of mammals and D-amino acid oxidase deficient rodents using two-dimensional high-performance liquid chromatography
    Hsiao, Sui-Wen
    Ishii, Chiharu
    Furusho, Aogu
    Hsieh, Chin-Ling
    Shimizu, Yukiko
    Akita, Takeyuki
    Mita, Masashi
    Okamura, Tadashi
    Konno, Ryuichi
    Ide, Tomomi
    Lee, Ching-Kuo
    Hamase, Kenji
    BIOCHIMICA ET BIOPHYSICA ACTA-PROTEINS AND PROTEOMICS, 2021, 1869 (01):
  • [26] A two-dimensional non-comprehensive reversed/normal phase high-performance liquid chromatography/tandem mass spectrometry system for determination of limonene and linalool hydroperoxides
    Ramzi, Ahmed
    Ahmadi, Hamid
    Sadiktsis, Ioannis
    Nilsson, Ulrika
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1566 : 102 - 110
  • [27] Off-line comprehensive two-dimensional reversed-phase countercurrent chromatography with high-performance liquid chromatography: Orthogonality in separation of Polygonum cuspidatum Sieb. et Zucc
    Wang, Xiang
    Zhao, Shanshan
    Wang, Chaoyue
    Sun, Wenyu
    Jin, Yang
    Gong, Xingchu
    Tong, Shengqiang
    JOURNAL OF SEPARATION SCIENCE, 2020, 43 (03) : 561 - 568
  • [28] Investigating the causes of low detectability of pesticides in fruits and vegetables analysed by high-performance liquid chromatography - Time-of-flight
    Muehlwald, S.
    Buchner, N.
    Kroh, L. W.
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1542 : 37 - 49
  • [29] Analysis of nine antioxidants in vegetable oils by high performance liquid chromatography
    Zhao Huinan
    Zhang Yanxia
    Xue Xia
    Dai Kun
    Zheng Wenjing
    Ma Cheng
    Zhu Jianhu
    Liu Yanming
    Zhang Feng
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2020, 38 (07) : 841 - 846
  • [30] Comprehensive high-performance liquid chromatographic method for the measurements of lipophilic antioxidants in human plasma
    Lee, Bee Lan
    Ong, Choon Nam
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (15) : 3131 - 3137