Microorganisms direct identification from blood culture by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry

被引:134
作者
Ferreira, L. [2 ]
Sanchez-Juanes, F. [2 ]
Porras-Guerra, I. [1 ]
Garcia-Garcia, M. I. [1 ]
Garcia-Sanchez, J. E. [1 ,4 ]
Gonzalez-Buitrago, J. M. [2 ,3 ]
Munoz-Bellido, J. L. [1 ,4 ]
机构
[1] Hosp Univ Salamanca, Dept Microbiol, Salamanca 37007, Spain
[2] Hosp Univ Salamanca, Unidad Invest, Salamanca 37007, Spain
[3] Univ Salamanca, Dept Bioquim & Biol Mol, E-37008 Salamanca, Spain
[4] Univ Salamanca, Dept Med Preventiva Salud Publ & Microbiol Med, E-37008 Salamanca, Spain
关键词
Bacteraemia; blood culture; fungaemia; MALDI-TOF; mass spectrometry; DESORPTION IONIZATION-TIME; GRAM-NEGATIVE BACILLI; RAPID IDENTIFICATION; SPECIES IDENTIFICATION; PATHOGENS; BACTERIA; ASSAY;
D O I
10.1111/j.1469-0691.2010.03257.x
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
P>Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) allows a fast and reliable bacterial identification from culture plates. Direct analysis of clinical samples may increase its usefulness in samples in which a fast identification of microorganisms can guide empirical treatment, such as blood cultures (BC). Three hundred and thirty BC, reported as positive by the automated BC incubation device, were processed by conventional methods for BC processing, and by a fast method based on direct MALDI-TOF MS. Three hundred and eighteen of them yield growth on culture plates, and 12 were false positive. The MALDI-TOF MS-based method reported that no peaks were found, or the absence of a reliable identification profile, in all these false positive BC. No mixed cultures were found. Among these 318 BC, we isolated 61 Gram-negatives (GN), 239 Gram-positives (GP) and 18 fungi. Microorganism identifications in GN were coincident with conventional identification, at the species level, in 83.3% of BC and, at the genus level, in 96.6%. In GP, identifications were coincident with conventional identification in 31.8% of BC at the species level, and in 64.8% at the genus level. Fungaemia was not reliably detected by MALDI-TOF. In 18 BC positive for Candida species (eight C. albicans, nine C. parapsilosis and one C. tropicalis), no microorganisms were identified at the species level, and only one (5.6%) was detected at the genus level. The results of the present study show that this fast, MALDI-TOF MS-based method allows bacterial identification directly from presumptively positive BC in a short time (< 30 min), with a high accuracy, especially when GN bacteria are involved.
引用
收藏
页码:546 / 551
页数:6
相关论文
共 23 条
[1]   Rapid identification and typing of Listeria species by matrix-assisted laser desorption ionization-time of flight mass spectrometry [J].
Barbuddhe, Sukhadeo B. ;
Maier, Thomas ;
Schwarz, Gerold ;
Kostrzewa, Markus ;
Hof, Herbert ;
Domann, Eugen ;
Chakraborty, Trinad ;
Hain, Torsten .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2008, 74 (17) :5402-5407
[2]   MALDI-TOF mass spectrometry to identify clinical bacterial isolates: Evaluation in a teaching hospital [J].
Blondiaux, N. ;
Gaillot, O. ;
Courcol, R. -J. .
PATHOLOGIE BIOLOGIE, 2010, 58 (01) :55-57
[3]   Matrix-assisted laser desorption ionization-time of flight mass spectrometry for identification of nonfermenting gram-negative bacilli isolated from cystic fibrosis patients [J].
Degand, Nicolas ;
Carbonnelle, Etienne ;
Dauphin, Brunhilde ;
Beretti, Jean-Luc ;
Le Bourgeois, Muriel ;
Sermet-Gaudelus, Isabelle ;
Segonds, Christine ;
Berche, Patrick ;
Nassif, Xavier ;
Ferroni, Agnes .
JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (10) :3361-3367
[4]   The urine dipstick test useful to rule out infections. A meta-analysis of the accuracy [J].
Devillé W.L.J.M. ;
Yzermans J.C. ;
Van Duijn N.P. ;
Bezemer P.D. ;
Van Der Windt D.A.W.M. ;
Bouter L.M. .
BMC Urology, 4 (1) :1-14
[5]   Rapid Classification and Identification of Salmonellae at the Species and Subspecies Levels by Whole-Cell Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry [J].
Dieckmann, Ralf ;
Helmuth, Reiner ;
Erhard, Marcel ;
Malorny, Burkhard .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2008, 74 (24) :7767-7778
[6]   Characterization of intact microorganisms by MALDI mass spectrometry [J].
Fenselau, C ;
Demirev, PA .
MASS SPECTROMETRY REVIEWS, 2001, 20 (04) :157-171
[7]  
Ferreira L, 2010, 20 EUR C CLIN MICR I
[8]   Challenging the problem of clostridial identification with matrix-assisted laser desorption and ionization-time-of-flight mass spectrometry (MALDI-TOF MS) [J].
Grosse-Herrenthey, Anke ;
Maier, Thomas ;
Gessler, Frank ;
Schaumann, Reiner ;
Boehnel, Helge ;
Kostrzewa, Markus ;
Krueger, Monika .
ANAEROBE, 2008, 14 (04) :242-249
[9]   Fluorescent in situ hybridization allows rapid identification of microorganisms in blood cultures [J].
Kempf, VAJ ;
Trebesius, K ;
Autenrieth, IB .
JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (02) :830-838
[10]   Direct Identification of Bacteria in Positive Blood Culture Bottles by Matrix-Assisted Laser Desorption Ionisation Time-of-Flight Mass Spectrometry [J].
La Scola, Bernard ;
Raoult, Didier .
PLOS ONE, 2009, 4 (11)